文献速递消化内镜消化道肿瘤与早癌

前瞻性随机对照研究评估双气囊介入内镜平台用于结直肠内镜黏膜下剥离术(附视频)

Prospective, randomized controlled study evaluating a double-balloon interventional endoscopic platform for colorectal endoscopic submucosal dissection (with video).
PubMed 文献 · Gastrointest Endosc · 2024-07-05

这项前瞻性随机对照试验将结直肠息肉≥2 cm患者按1:1随机分为双气囊介入平台辅助内镜黏膜下剥离术(DBIP-ESD)组与传统ESD(T-ESD)组,中期分析纳入140例。DBIP-ESD组平均手术时间88.6±42.7分钟,低于T-ESD组的139.5±83.2分钟(差值约51分钟,36.5%,P<.001),整块切除率97.2% vs 87.0%(P=.030),DBIP-ESD组无不良事件。

要点

  • DBIP-ESD组平均手术时间88.6±42.7分钟,较T-ESD组139.5±83.2分钟缩短约51分钟(36.5%),P<.001。
  • DBIP-ESD组整块切除率97.2%,高于T-ESD组的87.0%(P=.030)。
  • DBIP-ESD组缝合缺损闭合的平均导航时间减少7.7分钟(P<.001),且该组无不良事件。

核心结论

  • DBIP-ESD缩短了总手术时间,提高了整块切除率,并便于缝合缺损闭合,使DBIP成为提高结直肠ESD采纳率的有前景且具有成本效益的工具。

研究设计与样本

  • 前瞻性随机对照试验,计划样本量200例以达到≥80%把握度,计划在入组达70%时若主要终点达成(P≤.05)进行中期分析以提前终止研究。
  • 2019年2月至2020年2月共入组147例结直肠息肉≥2 cm患者,按1:1随机分配至DBIP-ESD组或T-ESD组。
  • 7例退出,中期分析基于140例患者(DBIP-ESD组71例,T-ESD组69例)。
  • 主要终点为两组平均总手术时间差异;次要终点包括术中时间点、整块切除率、手术费用、不良事件及3个月评估。

主要发现

  • DBIP-ESD组平均手术时间88.6±42.7分钟 vs T-ESD组139.5±83.2分钟,差值约51分钟(36.5%),P<.001。
  • 扣除DBIP成本后,每例患者节省费用610.16美元(11.4%)。
  • DBIP使剥离速度提高49.0%(15.1±8.0 vs 7.7±6.6 cm2/h,P<.001)。
  • DBIP-ESD组整块切除率97.2% vs T-ESD组87.0%(P=.030)。
  • DBIP-ESD组缝合缺损闭合的平均导航时间减少7.7分钟(P<.001),且DBIP-ESD组无不良事件。

临床怎么用

  • 原文结论认为DBIP-ESD缩短总手术时间、提高整块切除率并便于缝合缺损闭合,使DBIP成为提高结直肠ESD采纳率的有前景且具有成本效益的工具。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUNDS AND AIMS: Endoscopic submucosal dissection (ESD) can be challenging and time-consuming. A double-balloon interventional platform (DBIP) was designed to assist with navigation, stabilization, traction, and device delivery during complex colorectal polypectomy. We compared traditional ESD (T-ESD) with DBIP-assisted ESD (DBIP-ESD) in a prospective, randomized trial. METHODS: Patients with colorectal polyps ≥2 cm were randomly assigned (1:1) to DBIP-ESD or T-ESD. The primary study endpoint was the mean total procedure time difference between groups. Secondary endpoints were intraprocedural time points, en bloc resection rate, procedure cost, adverse events, and 3-month assessment. A sample size of 200 subjects for ≥80% power was calculated. Interim analysis for early study termination was planned at 70% enrollment if the primary endpoint was met (P ≤ .05). RESULTS: One hundred forty-seven patients were enrolled between February 2019 and February 2020. Seven patients dropped out, and the interim analysis was performed on 140 patients (71 DBIP-ESD, 69 T-ESD). Demographics, comorbidities, and lesion size, location, and classification were similar between groups. The mean procedure time decreased with DBIP-ESD (88.6 ± 42.7 minutes) versus T-ESD (139.5 ± 83.2 minutes; difference of ∼51 minutes [36.5%]; P < .001], with procedural savings of $610.16 (11.4%) per patient after DBIP cost. The DBIP increased dissection speed by 49.0% (15.1 ± 8.0 vs 7.7 ± 6.6 cm2/h, P < .001). En bloc resection was superior with the addition of DBIP (97.2% vs 87.0%, P = .030). The mean navigation time with DBIP-ESD for sutured defect closure decreased by 7.7 minutes (P < .001). There were no adverse events in the DBIP-ESD group. CONCLUSIONS: DBIP-ESD decreased the total procedure time, improved the en bloc resection rate, and facilitated sutured defect closure, making DBIP a promising and cost-effective tool to improve colorectal ESD adoption. (Clinical trial registration number: NCT03846609.).

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Kantsevoy SV, Palmer A, Hockett D, et al. Prospective, randomized controlled study evaluating a double-balloon interventional endoscopic platform for colorectal endoscopic submucosal dissection (with video). Gastrointest Endosc. 2024. PMID: 38971202. doi:10.1016/j.gie.2024.07.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。