文献速递肝病消化内镜

基于振动控制瞬时弹性成像的参数预测肝移植受者的临床结局

Vibration-Controlled Transient Elastography-Based Parameters Predict Clinical Outcomes in Liver Transplant Recipients.
PubMed 文献 · Clin Gastroenterol Hepatol · 2024-07-04

研究纳入2015至2022年间362例VCTE检查成功的成人肝移植受者,以LSM≥10.5 kPa定义进展期纤维化、CAP≥270 dB/m定义肝脂肪变,采用竞争风险累积发病率分析。中位随访65个月,基线高LSM与全因死亡(HR 1.97)及新发肝硬化(HR 6.74)独立相关,高CAP与心肌梗死风险独立相关(HR 4.14)。

要点

  • 肝移植受者中LSM升高占18%,CAP升高占45%。
  • 基线高LSM与全因死亡(HR 1.97)和新发肝硬化(HR 6.74)独立相关。
  • 较高CAP值与随访期间心肌梗死风险增加独立相关(HR 4.14)。

核心结论

  • 基于VCTE的参数与临床结局相关,有望纳入临床风险分层策略以改善肝移植受者结局。

研究设计与样本

  • 纳入2015至2022年间362例VCTE检查成功的成人肝移植受者,采用竞争风险累积发病率分析。
  • 进展期纤维化定义为LSM≥10.5 kPa,肝脂肪变定义为CAP≥270 dB/m。

主要发现

  • LSM升高者64例(18%),CAP升高者163例(45%)。
  • CAP升高与CAP正常患者的基线LSM值相似。
  • 自肝移植至基线VCTE的中位随访65个月(四分位距20-140个月)期间,66例(18%)死亡,12例(3%)发生移植物肝硬化,18例(5%)发生心肌梗死。
  • 基线高LSM与全因死亡独立相关(HR 1.97;95%CI 1.11-3.50;P=.02),与新发肝硬化独立相关(HR 6.74;95%CI 2.08-21.79;P<.01)。
  • 较高CAP值与随访期间心肌梗死风险增加显著且独立相关(HR 4.14;95%CI 1.29-13.27;P=.017)。

临床怎么用

  • 原文结论认为基于VCTE的参数与临床结局相关,并有望纳入临床风险分层策略以改善肝移植受者结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Vibration-controlled transient elastography (VCTE) is used in clinical practice to risk-stratify liver transplant (LT) recipients; however, there are currently little data demonstrating the relationship between VCTE and clinical outcomes. METHODS: A total of 362 adult LT recipients with successful VCTE examination between 2015 and 2022 were included. Presence of advanced fibrosis was defined as liver stiffness measurement (LSM) ≥10.5 kPa and hepatic steatosis as controlled attenuation parameter (CAP) ≥270 dB/m. The outcomes of interest included all-cause mortality, myocardial infarction (MI), and graft cirrhosis using cumulative incidence analysis that accounted for the competing risks of these outcomes. RESULTS: The LSM was elevated in 64 (18%) and CAP in 163 (45%) LT recipients. The baseline LSM values were similar in patients with elevated vs normal CAP values. After a median follow-up of 65 (interquartile range, 20-140) months from LT to baseline VCTE, 66 (18%) patients died, 12 (3%) developed graft cirrhosis, and 18 (5%) experienced an MI. Baseline high LSM was independently associated with all-cause mortality (hazard ratio [HR], 1.97; 95% confidence interval [CI], 1.11-3.50; P = .02) and new onset cirrhosis (HR, 6.74; 95% CI, 2.08-21.79; P < .01). A higher CAP value was significantly and independently associated with increased risk of experiencing a MI over study follow-up (HR, 4.14; 95% CI, 1.29-13.27; P = .017). CONCLUSIONS: The VCTE-based parameters are associated with clinical outcomes and offer the potential to be incorporated into clinical risk-stratification strategies to improve outcomes among LT recipients.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Baral A, Garg S, Nguyen M, et al. Vibration-Controlled Transient Elastography-Based Parameters Predict Clinical Outcomes in Liver Transplant Recipients. Clin Gastroenterol Hepatol. 2024. PMID: 38969073. doi:10.1016/j.cgh.2024.06.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。