文献速递炎症性肠病消化内镜

利用粪便照片的深度学习模型预测溃疡性结肠炎患者内镜下黏膜炎症

Deep Learning Model Using Stool Pictures for Predicting Endoscopic Mucosal Inflammation in Patients With Ulcerative Colitis.
PubMed 文献 · Am J Gastroenterol · 2024-07-25

这项前瞻性多中心研究在6家三级转诊医院开发了基于粪便照片的深度学习模型(DLSUC),用于预测溃疡性结肠炎的内镜下黏膜炎症。DLSUC在预测内镜活动度方面的AUC为0.801,与粪便钙卫蛋白(Fcal)的AUC 0.837无统计学差异(DeLong P=0.458);排除直肠豁免病例后AUC提升至0.849。DLSUC判定的活动期患者在中位8个月随访期间更易出现疾病复发(log-rank检验 P=0.002)。

要点

  • DLSUC预测内镜活动度的AUC为0.801,与Fcal的0.837相比无统计学差异(DeLong P=0.458)。
  • 排除直肠豁免病例后,DLSUC的AUC提升至0.849,准确度、敏感度、特异度分别为0.845、0.745、0.958。
  • DLSUC判定的活动期患者在中位8个月随访中更易出现疾病复发(log-rank检验 P=0.002)。

核心结论

  • DLSUC在预测内镜活动度方面表现出与Fcal相似的区分能力,在无直肠豁免的患者中准确度更高。
  • 本研究提示粪便照片是典型溃疡性结肠炎的有用监测工具。

研究设计与样本

  • 前瞻性多中心研究,在6家三级转诊医院开展。
  • 计划进行内镜黏膜炎症监测的患者被要求在计划内镜日前1周内用智能手机拍摄粪便照片。
  • DLSUC使用来自306例患者的2161张粪便照片开发,并在来自126例患者的1047张粪便图像上测试。
  • 采用溃疡性结肠炎内镜严重程度指数(UCEIS)定义内镜活动度。

主要发现

  • DLSUC预测内镜活动度的AUC为0.801(95%CI 0.717-0.873),与Fcal的AUC 0.837(95%CI 0.767-0.899)相比无统计学差异(DeLong P=0.458)。
  • 排除直肠豁免病例(23/126,18.2%)后,DLSUC的AUC增至0.849(95%CI 0.760-0.919)。
  • DLSUC在所有患者中预测内镜活动度的准确度、敏感度、特异度分别为0.746、0.662、0.877。
  • 在无直肠豁免的患者中,DLSUC的准确度、敏感度、特异度分别为0.845、0.745、0.958。
  • DLSUC判定的活动期患者在中位8个月随访期间更易出现疾病复发(log-rank检验 P=0.002)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Stool characteristics may change depending on the endoscopic activity of ulcerative colitis (UC). We developed a deep learning model using stool photographs of patients with UC (DLSUC) to predict endoscopic mucosal inflammation. METHODS: This was a prospective multicenter study conducted in 6 tertiary referral hospitals. Patients scheduled to undergo endoscopy for mucosal inflammation monitoring were asked to take photographs of their stool using smartphones within 1 week before the day of endoscopy. DLSUC was developed using 2,161 stool pictures from 306 patients and tested on 1,047 stool images from 126 patients. The UC endoscopic index of severity was used to define endoscopic activity. The performance of DLSUC in endoscopic activity prediction was compared with that of fecal calprotectin (Fcal). RESULTS: The area under the receiver operating characteristic curve (AUC) of DLSUC for predicting endoscopic activity was 0.801 (95% confidence interval [CI] 0.717-0.873), which was not statistically different from the AUC of Fcal (0.837 [95% CI, 0.767-0.899, DeLong P = 0.458]). When rectal-sparing cases (23/126, 18.2%) were excluded, the AUC of DLSUC increased to 0.849 (95% CI, 0.760-0.919). The accuracy, sensitivity, and specificity of DLSUC in predicting endoscopic activity were 0.746, 0.662, and 0.877 in all patients and 0.845, 0.745, and 0.958 in patients without rectal sparing, respectively. Active patients classified by DLSUC were more likely to experience disease relapse during a median 8-month follow-up (log-rank test, P = 0.002). DISCUSSION: DLSUC demonstrated a good discriminating power similar to that of Fcal in predicting endoscopic activity with improved accuracy in patients without rectal sparing. This study implies that stool photographs are a useful monitoring tool for typical UC.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Lee JW, Woo D, Kim KO, et al. Deep Learning Model Using Stool Pictures for Predicting Endoscopic Mucosal Inflammation in Patients With Ulcerative Colitis. Am J Gastroenterol. 2024. PMID: 39051648. doi:10.14309/ajg.0000000000002978

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。