混合内镜黏膜下剥离术与传统内镜黏膜下剥离术治疗结直肠病变的多中心随机对照试验(Short-ESD试验)
这项多中心随机对照试验比较混合内镜黏膜下剥离术(H-ESD)与传统内镜黏膜下剥离术(C-ESD)治疗20至50 mm无蒂结直肠病变的效果。H-ESD组平均手术时间显著短于C-ESD组(41.1±16.3分钟 vs 54.3±28.2分钟,P=0.007),整块切除率和R0切除率在H-ESD组有降低趋势但未达统计学显著,不良事件率两组相似。
要点
- H-ESD平均手术时间显著短于C-ESD(41.1±16.3分钟 vs 54.3±28.2分钟,P=0.007)。
- H-ESD与C-ESD的整块切除率(77.5% vs 87.8%,P=0.26)和R0切除率(72.5% vs 79.6%,P=0.46)无显著差异。
- H-ESD与C-ESD不良事件率相似(10% vs 8.2%,P=1.00)。
核心结论
- H-ESD和C-ESD对大结直肠病变的切除均安全有效,H-ESD手术时间更短,可能成为C-ESD的可行替代方案,主要优势在于圈套器技术易于应用。
- 未来需进一步研究以确定最适合H-ESD的病变,从而在不影响切除结果的前提下优化效率与安全性。
研究设计与样本
- 多中心随机对照试验(Short-ESD试验),将20至50 mm结直肠病变患者按1:1随机分配至H-ESD组或C-ESD组。
- 共纳入89例患者(中位年龄63岁,女性49.3%),中位息肉大小30 mm,H-ESD组40例,C-ESD组49例。
- 主要结局为手术时间/速度,次要结局为整块切除率、完整(R0)切除率和不良事件率。
主要发现
- H-ESD组平均手术时间显著短于C-ESD组(41.1±16.3分钟 vs 54.3±28.2分钟,P=0.007)。
- 整块切除率H-ESD组77.5% vs C-ESD组87.8%(P=0.26),R0切除率H-ESD组72.5% vs C-ESD组79.6%(P=0.46),均未达统计学显著。
- 不良事件率H-ESD组10% vs C-ESD组8.2%(P=1.00),两组相似。
临床怎么用
- 原文未据此给出推荐。
局限性
- 未来需进一步研究以确定最适合H-ESD的病变,从而在不影响切除结果的前提下优化效率与安全性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Hybrid endoscopic submucosal dissection (H-ESD), which utilizes ESD knife along with snare-based resection, has been developed to overcome the technical complexity of conventional ESD (C-ESD). The aim of this study was to compare the therapeutic outcomes of H-ESD vs C-ESD for nonpedunculated colorectal lesions ≥20 mm in size. METHODS: We conducted a multicenter randomized controlled trial to compare H-ESD and C-ESD (Short-ESD trial). Patients with colorectal lesions between 20 and 50 mm in size were randomly assigned (1:1) to H-ESD or C-ESD. Primary outcome was procedure time/speed. Secondary outcomes were en bloc and complete (R0) resection rates and adverse event rates. RESULTS: A total of 89 patients (median age 63 years; 49.3% women) with the median polyp size of 30 mm underwent H-ESD (n = 40) and C-ESD (n = 49). The mean procedure time of H-ESD was significantly shorter than that of C-ESD (41.1 ± 16.3 vs 54.3 ± 28.2 minutes; P = 0.007). The en bloc and R0 resection rates trended lower in the H-ESD vs C-ESD groups (77.5% vs 87.8%; P = 0.26% and 72.5% vs 79.6%; P = 0.46) without reaching statistical significance. Adverse event rate was similar between H-ESD and C-ESD (10% vs 8.2%; P = 1.00). DISCUSSION: Both H-ESD and C-ESD were safe and effective for resection of large colorectal lesions. H-ESD was associated with a shorter procedure time. H-ESD may represent a viable alternative to C-ESD, with the main advantage being easy applicability of a snare-based technique for colorectal lesions. Future studies are needed to further define the most suitable lesions for H-ESD, as to optimize efficiency and safety without compromising resection outcomes. ClinicaTrials.gov NCT NCT05347446.
引用
- Yang D, Hasan MK, Jawaid S, et al. Hybrid Versus Conventional Colorectal Endoscopic Submucosal Dissection: A Multicenter Randomized Controlled Trial (Short-Endoscopic Submucosal Dissection). Am J Gastroenterol. 2024. PMID: 38912697. doi:10.14309/ajg.0000000000002897
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。