振动控制瞬时弹性成像与磁共振弹性成像在肝硬化患者中的可重复性比较:一项前瞻性研究
这项前瞻性研究纳入49例肝硬化成人,评估同日重复肝硬度测量(LSM)的可重复性。磁共振弹性成像(MRE)的重复性系数百分比(RC%)为21%,振动控制瞬时弹性成像(VCTE)为38%,VCTE较MRE高82%。两种方法的测量变异性均随疾病严重程度增加。
要点
- MRE的RC%为21%,VCTE为38%,VCTE较MRE高82%。
- VCTE的受试者内变异系数(wCV)为14%,MRE为8%,VCTE较MRE高75%。
- VCTE和MRE的组内相关系数(ICC)分别为0.92和0.96,均属优秀。
核心结论
- VCTE和MRE的测量变异性均随疾病严重程度增加,但MRE在肝硬化患者中的技术可重复性优于VCTE。
研究设计与样本
- 前瞻性研究,纳入49例肝硬化成人(58.3%为女性),进行同日重复肝硬度测量(LSM)检查。
- 同日重复MRE和VCTE检查分别有33例和45例参与者完成。
主要发现
- VCTE的RC%为38%,MRE为21%,VCTE较MRE高82%,在头对头分析中结果一致。
- VCTE的wCV为14%,MRE为8%,VCTE的受试者内测量变异较MRE高75%。
- VCTE和MRE的LSM组内相关系数(ICC)分别为0.92和0.96,均属优秀。
- VCTE的测量变异性(四分位距)随平均肝硬度增加(R²=0.78),MRE的测量变异性(标准差)也随平均肝硬度增加(R²=0.93)。
临床怎么用
- 这些可重复性估计可能改善无创检查(NITs)在实践中的资格认定。
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Magnetic resonance elastography (MRE) and vibration-controlled transient elastography (VCTE) have the potential to assess disease progression; however, repeatability data in people with cirrhosis are lacking. We aimed to assess the effect of disease severity on measurement variability and contribute to the evidentiary basis for the qualification of repeating liver stiffness measurements (LSM) in practice and research. METHODS: This prospective study included 49 adult participants (58.3% female) with cirrhosis who underwent same-day repeat LSM examinations. The primary outcome was the same-day, same-operator repeatability coefficient% (RC%) and the within-case coefficient of variation (wCV) for each modality. Secondary outcomes include the intra-class correlation coefficient (ICC). The relationship between measurement variability (interquartile for VCTE, standard deviation for MRE) and disease severity (mean liver stiffness) was evaluated by linear regression with the coefficient of determination R2 reported. RESULTS: Same-day repeat MRE and VCTE exams were prospectively conducted in 33 and 45 participants, respectively. The RC% appeared 82% higher for VCTE versus MRE (38% vs. 21%), with consistent findings in head-to-head analyses. The wCV for VCTE and MRE was 14% and 8% respectively, indicating VCTE has 75% higher within-subject measurement variation than MRE. ICC was excellent for LSM by VCTE (0.92) and MRE (0.96). Measurement variability increased with mean liver stiffness for VCTE (R2 = 0.78) and MRE (R2 = 0.93). CONCLUSION: Both VCTE and MRE demonstrated increased measurement variability with disease severity. However, MRE outperformed VCTE in terms of technical repeatability in patients with cirrhosis. These repeatability estimates may improve the qualification of NITs in practice.
引用
- Siddiqi H, Huang DQ, Mittal N, et al. Repeatability of vibration-controlled transient elastography versus magnetic resonance elastography in patients with cirrhosis: A prospective study. Aliment Pharmacol Ther. 2024. PMID: 38863232. doi:10.1111/apt.18118
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。