文献速递胰腺与胆道疾病消化内镜

夹子锚定对预防内镜逆行胰胆管造影术中全覆膜自膨式金属支架移位的效果:多中心随机对照研究

Effects of Clip Anchoring on Preventing Migration of Fully Covered Self-Expandable Metal Stent in Patients Undergoing Endoscopic Retrograde Cholangiopancreatography: A Multicenter, Randomized Controlled Study.
PubMed 文献 · Am J Gastroenterol · 2024-04-15

多中心随机对照研究纳入180例胆道狭窄需放置全覆膜自膨式金属支架(FCSEMS)患者,1:1随机分为夹子锚定组与对照组。6个月支架移位率夹子组显著低于对照组(16.7% vs 30.0%,P=0.030),近端和远端移位率两组相似,支架相关不良事件无显著差异。作者认为夹子辅助锚定是预防FCSEMS移位的有效且安全的方法。

要点

  • 6个月支架移位率夹子组16.7% vs 对照组30.0%,P=0.030。
  • 近端移位率2.2% vs 5.6%(P=0.205),远端移位率14.4% vs 22.2%(P=0.070)。
  • 使用2个及以上夹子的8例患者中无支架移位发生(0/8)。

核心结论

  • 夹子辅助锚定是预防FCSEMS移位的有效且安全的方法,且不增加不良事件。

研究设计与样本

  • 多中心随机对照试验,2020年2月至2022年11月连续纳入180例胆道狭窄需放置FCSEMS的患者,1:1随机分为夹子锚定组(clip组)和对照组,每组90例,按意向性治疗原则分析。

主要发现

  • 6个月支架总体移位率夹子组16.7% vs 对照组30.0%(P=0.030)。
  • 近端移位率夹子组2.2% vs 对照组5.6%(P=0.205),远端移位率夹子组14.4% vs 对照组22.2%(P=0.070)。
  • 使用2个及以上夹子的8例患者中无支架移位发生(0/8)。
  • 两组支架相关不良事件无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Fully covered self-expandable metal stents (FCSEMSs) are commonly placed in patients with biliary stricture during endoscopic retrograde cholangiopancreatography (ERCP). However, up to 40% of migration has been reported, resulting in treatment failure or the requirement for further intervention. Here, we aimed to investigate the effects of metal clip anchoring on preventing the migration of FCSEMS. METHODS: Consecutive patients requiring placement of FCSEMS were included in this multicenter randomized trial. The enrolled patients were randomly assigned in a 1:1 ratio to receive clip anchoring (clip group) or not (control group). The primary outcome was the migration rate at 6 months after stent insertion. The secondary outcomes were the rates of proximal and distal migration and stent-related adverse events. The analysis followed the intention-to-treat principle. RESULTS: From February 2020 to November 2022, 180 patients with biliary stricture were enrolled, with 90 in each group. The baseline characteristics were comparable between the 2 groups. The overall rate of stent migration at 6 months was significantly lower in the clip group compared with the control group (16.7% vs 30.0%, P = 0.030). The proximal and distal migration rates were similar in the 2 groups (2.2% vs 5.6%, P = 0.205; 14.4% vs 22.2%, P = 0.070). Notably, none of the patients (0/8) who received 2 or more clips experienced stent migration. There were no significant differences in stent-related adverse events between the 2 groups. DISCUSSION: Our data suggest that clip-assisted anchoring is an effective and safe method for preventing migration of FCSEMS without increasing the adverse events.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Wang X, Shi X, Luo H, et al. Effects of Clip Anchoring on Preventing Migration of Fully Covered Self-Expandable Metal Stent in Patients Undergoing Endoscopic Retrograde Cholangiopancreatography: A Multicenter, Randomized Controlled Study. Am J Gastroenterol. 2024. PMID: 38619136. doi:10.14309/ajg.0000000000002813

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。