文献速递消化内镜消化道肿瘤与早癌

自组装肽凝胶预防食管内镜黏膜下剥离术后狭窄:美国多中心前瞻性研究(附视频)

The use of a self-assembling peptide gel for stricture prevention in the esophagus after endoscopic submucosal dissection: a U.S. multicenter prospective study (with video).
PubMed 文献 · Gastrointest Endosc · 2024-03-10

这项美国多中心前瞻性研究纳入43例食管内镜黏膜下剥离术(ESD)后黏膜缺损≥50%周径的患者,术中应用自组装肽(SAP)凝胶,总体狭窄率20.9%(9/43),高危病例(缺损≥75%周径)狭窄率30.8%,其中环形ESD后80%(4/5)、缺损≥75%但<100%周径者19%(4/21);所有狭窄均经内镜治疗缓解,术后出血3例(6.9%)均经内镜处理。作者认为SAP凝胶应用简便快速,狭窄率相对较低,与其他预防方法相当,需进一步比较研究证实。

要点

  • 食管ESD黏膜缺损≥50%周径者应用SAP凝胶,总体狭窄率20.9%(9/43)。
  • 高危病例(缺损≥75%周径)狭窄率30.8%,环形ESD后为80%(4/5)。
  • 所有狭窄均经内镜治疗缓解,术后出血3例(6.9%)经内镜处理。

核心结论

  • 作者认为SAP凝胶应用简便快速,狭窄率相对较低,与其他预防方法相当。
  • 作者指出需进一步比较研究证实这些初步发现。

研究设计与样本

  • 多中心前瞻性研究,纳入2022年3月至2023年12月接受食管ESD并应用SAP凝胶的患者。
  • 纳入标准为ESD黏膜缺损≥50%食管周径;高危病例定义为黏膜缺损≥75%周径。
  • 共43例患者,中位年龄71岁,男性81.4%,中位切除标本大小50 mm。
  • SAP凝胶中位用量3 mL,中位应用时间4分钟,所有病例均成功应用。

主要发现

  • 总体狭窄率20.9%(9/43)。
  • 高危病例狭窄率30.8%:环形ESD后80%(4/5),缺损≥75%但<100%周径者19%(4/21)。
  • 所有狭窄均经内镜治疗缓解。
  • 术后出血3例(6.9%),均经内镜充分处理。

关键数值与推荐

  • 狭窄定义为无法通过直径≥8.9 mm内镜或症状性窄口径管腔。
  • 高危病例定义为黏膜缺损≥75%食管周径。

局限性

  • 作者指出需进一步比较研究证实这些初步发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Postoperative stricture is a serious common adverse event after extensive endoscopic submucosal dissection (ESD) in the esophagus. Self-assembling peptide (SAP) gel has been shown to promote tissue healing and re-epithelialization. The aim of this study was to evaluate the effect of the SAP gel for esophageal stricture prevention after ESD. METHODS: This was a multicenter prospective study of patients who underwent esophageal ESD followed by SAP gel application between March 2022 and December 2023. Patients were included if the ESD mucosal defect involved ≥50% of the circumference of the esophagus. High-risk cases were defined as mucosal defects ≥75% of the circumference. Stricture was defined as the inability to pass an endoscope ≥8.9 mm in diameter or a narrow-caliber lumen in a patient with symptoms. RESULTS: A total of 43 patients (median age, 71 years; 81.4% male) underwent ESD (median resected specimen size, 50 mm) during the study period. SAP gel (median, 3 mL) was successfully applied in all cases (median time, 4 minutes). In aggregate, stricture occurred in 20.9% (9 of 43) of the cases. Stricture developed in 30.8% of the high-risk cases: 80% (4 of 5) after circumferential ESD and 19% (4 of 21) in those with defects ≥75% but <100% of the circumference. All cases of stricture resolved with endoscopic treatment. Three cases (6.9%) of postoperative bleeding occurred and were adequately managed endoscopically. CONCLUSIONS: We show that SAP gel application was easy, quick, and associated with a relatively low stricture rate comparable to other prophylactic methods. Additional comparative studies are needed to corroborate these preliminary findings.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Yang D, Hasan MK, Xiao Y, et al. The use of a self-assembling peptide gel for stricture prevention in the esophagus after endoscopic submucosal dissection: a U.S. multicenter prospective study (with video). Gastrointest Endosc. 2024. PMID: 38467200. doi:10.1016/j.gie.2024.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。