PubMed 文献 · Clin Gastroenterol Hepatol · 2024-03-02

单中心实用性随机对照试验纳入1100例结肠镜检查患者,随机分入传统结肠镜组或实时计算机辅助检测组,计算机辅助检测组腺瘤检出率显著高于传统组(42.5% vs 34.4%,P = .005),腺瘤检出改善主要由<5 mm腺瘤检出增加驱动。

要点

  • 计算机辅助检测组腺瘤检出率显著高于传统组(42.5% vs 34.4%,P = .005)
  • 计算机辅助检测组每结肠镜腺瘤数显著高于传统组(0.89 ± 1.46 vs 0.60 ± 1.12,P < .001)
  • 计算机辅助检测组无蒂锯齿状病变检出率高于传统组(4.7% vs 2.0%,P = .01)

核心结论

  • 在单中心实用性随机对照试验中,实时计算机辅助检测中等检出水平的社区内镜医师的腺瘤检出率和每结肠镜腺瘤数有适度改善。

研究设计与样本

  • 单中心实用性随机对照试验,2022年9月至2023年3月在一家社区中心纳入1100例因结直肠癌筛查、监测、粪便免疫化学检测阳性或诊断指征接受结肠镜检查的患者,按1:1随机分入传统结肠镜组或实时计算机辅助检测组,由盲法病理学家分析组织病理学结果。

主要发现

  • 计算机辅助检测组腺瘤检出率显著高于传统结肠镜组(42.5% vs 34.4%;P = .005)。
  • 计算机辅助检测组每结肠镜腺瘤数均值显著高于传统结肠镜组(0.89 ± 1.46 vs 0.60 ± 1.12;P < .001)。
  • 计算机辅助检测的腺瘤检出改善由<5 mm腺瘤检出增加驱动。
  • 计算机辅助检测组无蒂锯齿状病变检出率高于传统结肠镜组(4.7% vs 2.0%;P = .01)。
  • 计算机辅助检测的腺瘤检出率改善在研究前半期显著高于传统组(47.2% vs 33.7%;P = .002),研究后半期两组无显著差异(38.7% vs 34.9%;P = .33)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: The use of computer-aided detection (CADe) has increased the adenoma detection rates (ADRs) during colorectal cancer (CRC) screening/surveillance in randomized controlled trials (RCTs) but has not shown benefit in real-world implementation studies. We performed a single-center pragmatic RCT to evaluate the impact of real-time CADe on ADRs in colonoscopy performed by community gastroenterologists. METHODS: We enrolled 1100 patients undergoing colonoscopy for CRC screening, surveillance, positive fecal-immunohistochemical tests, and diagnostic indications at one community-based center from September 2022 to March 2023. Patients were randomly assigned (1:1) to traditional colonoscopy or real-time CADe. Blinded pathologists analyzed histopathologic findings. The primary outcome was ADR (the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy (APC), sessile-serrated lesion detection rate, and non-neoplastic resection rate. RESULTS: The median age was 55.5 years (interquartile range, 50-62 years), 61% were female, 72.7% were of Hispanic ethnicity, and 9.1% had inadequate bowel preparation. The ADR for the CADe group was significantly higher than the traditional colonoscopy group (42.5% vs 34.4%; P = .005). The mean APC was significantly higher in the CADe group compared with the traditional colonoscopy group (0.89 ± 1.46 vs 0.60 ± 1.12; P < .001). The improvement in adenoma detection was driven by increased detection of <5 mm adenomas. CADe had a higher sessile-serrated lesion detection rate than traditional colonoscopy (4.7% vs 2.0%; P = .01). The improvement in ADR with CADe was significantly higher in the first half of the study (47.2% vs 33.7%; P = .002) compared with the second half (38.7% vs 34.9%; P = .33). CONCLUSIONS: In a single-center pragmatic RCT, real-time CADe modestly improved ADR and APC in average-detector community endoscopists. (ClinicalTrials.gov number, NCT05963724).

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Thiruvengadam NR, Solaimani P, Shrestha M, et al. The Efficacy of Real-time Computer-aided Detection of Colonic Neoplasia in Community Practice: A Pragmatic Randomized Controlled Trial. Clin Gastroenterol Hepatol. 2024. PMID: 38437999. doi:10.1016/j.cgh.2024.02.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。