这项前瞻性多中心研究由3个中心的5名经验丰富操作者连续完成50例结直肠内镜黏膜下剥离术,使用ATRACT牵引装置,病变平均直径66.6 mm、平均操作时间55.2分钟、平均切除速度61.4 mm2/min,整块切除率100%、R0切除率98%、治愈性切除率94%,穿孔4例(8%)均内镜下闭合无需手术,迟发出血1例(2%)。作者认为该策略有效安全且切除速度高,但需在更大规模研究及非专家中心确认。

要点

  • 使用ATRACT装置的自适应牵引策略在结直肠ESD中整块切除率100%、R0切除率98%。
  • 平均切除速度61.4 mm2/min,高于既往口袋法23.5 mm2/min和双夹牵引法39.1 mm2/min的报道。
  • 穿孔4例(8%)均内镜下闭合无需手术,迟发出血1例(2%)。

核心结论

  • 这项前瞻性评估证实,使用ATRACT装置的自适应牵引策略在结直肠ESD中有效且安全,切除速度高。

研究设计与样本

  • 前瞻性多中心研究,来自3个中心的5名经验丰富操作者连续完成50例结直肠ESD(49例患者),病变直径4至10 cm且位于常规部位。

主要发现

  • 2022年11月至2023年4月共完成50例ESD,病变平均主直径为66.6 mm,表面积为3066 mm2。
  • 平均操作时间为55.2分钟,平均切除速度为61.4 mm2/min。
  • 整块切除率和R0切除率分别为100%和98%,治愈性切除率为94%。
  • 发生4例(8%)穿孔,均经内镜下闭合而无需手术;注意到1例(2%)迟发出血。
  • 既往研究报告口袋法速度为23.5 mm2/min、双夹牵引技术速度为39.1 mm2/min,本研究为文献中结直肠ESD最高切除速度的系列。

临床怎么用

  • 作者认为这些结果需要在更大规模研究及非专家中心中确认。

局限性

  • 这些结果需要在更大规模研究及非专家中心中确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Traction has become the reference strategy for colorectal endoscopic submucosal dissection (ESD). One of its major limitations is that the force of traction decreases as dissection progresses. The ATRACT traction device (ATRACT Device and Co, Lyon, France) uses a pulley system to increase traction during the procedure, making it easier and faster. A retrospective study of 54 cases showed interesting results in terms of efficacy and safety throughout the digestive tract. We sought to confirm these initial results with a prospective study of resections of colorectal lesions. METHODS: In this prospective multicenter study, 5 experienced operators from 3 different centers each performed 10 procedures using the ATRACT device consecutively for all conventional colorectal ESDs measuring between 4 and 10 cm in conventional locations (no recurrent lesions, appendicular, of the ileocecal valve, in contact with the pectinate line, or measuring more than two-thirds of the circumference). RESULTS: Between November 2022 and April 2023, 50 ESDs were performed in 49 patients. On average, the main diameter of the lesions was 66.6 mm, with a surface area of 3066 mm2. The mean operating time was 55.2 minutes, resulting in a mean resection speed of 61.4 mm2/min. En bloc and R0 resection rates were 100% and 98%, respectively. Resections were curative in 94% of cases. Four (8%) perforations occurred, all of which were closed endoscopically without the need for surgery. One (2%) case of delayed hemorrhage was noted. To date, this is the series with the highest resection speeds in the literature for colorectal ESD. For comparison, previous studies reported a speed of 23.5 mm2/min using the "pocket" strategy and a speed of 39.1 mm2/min using the double-clip traction technique. These results need to be confirmed in larger studies and in nonexpert centers. CONCLUSIONS: This prospective evaluation confirms the efficacy and safety of the adaptive traction strategy with the ATRACT device for colorectal ESD with high resection speed.