实时计算机辅助息肉检测系统(ENDO-AID)对受训内镜医师腺瘤检出率的影响:一项随机试验
在中国香港开展的单盲、平行组随机对照试验(2021年4月至2022年7月,NCT04838951)中,接受筛查、监测或诊断性结肠镜检查的受试者按1:1随机接受CADe(ENDO-AID[OIP-1])辅助或对照结肠镜检查,操作者为完成操作少于500例且经验少于3年的受训内镜医师。CADe组总体腺瘤检出率显著高于对照组(57.5% vs 44.5%;校正相对危险度1.41;95%CI 1.17-1.72;P<.001)。
要点
- 受训内镜医师使用CADe可提高总体腺瘤检出率(57.5% vs 44.5%;校正RR 1.41;95%CI 1.17-1.72;P<.001)。
- CADe组<5 mm腺瘤检出率(40.4% vs 25.0%)和5-10 mm腺瘤检出率(36.8% vs 29.2%)均高于对照组。
- 晚期腺瘤检出率两组无显著差异;CADe组平均腺瘤数(1.48 vs 0.86)和非肿瘤性切除率(52.1% vs 35.0%)更高。
核心结论
- 在受训内镜医师中,结肠镜检查时使用CADe与总体腺瘤检出率升高相关。
研究设计与样本
- 单盲、平行组随机对照试验,于2021年4月至2022年7月在中国香港开展(NCT04838951)。
- 受试者按1:1随机接受CADe(ENDO-AID[OIP-1])辅助或对照结肠镜检查,操作者为完成操作少于500例且经验少于3年的受训内镜医师。
- 随机化按患者年龄、性别和内镜医师经验(初级 vs 中级,<200例 vs 200-500例操作)分层。
- 禁止使用图像增强和远端附件装置;排除结肠镜检查不完整或肠道准备不充分的受试者。
- CADe组386例、对照组380例受试者;结局评估者对治疗分配设盲。
主要发现
- 总体腺瘤检出率CADe组57.5% vs 对照组44.5%(校正相对危险度1.41;95%CI 1.17-1.72;P<.001)。
- <5 mm腺瘤检出率CADe组40.4% vs 对照组25.0%;5-10 mm腺瘤检出率CADe组36.8% vs 对照组29.2%。
- 右半结肠腺瘤检出率CADe组42.0% vs 对照组30.8%;左半结肠腺瘤检出率CADe组34.5% vs 对照组27.6%;晚期腺瘤检出率两组无显著差异。
- 初级内镜医师腺瘤检出率CADe组60.0% vs 对照组41.9%;中级内镜医师腺瘤检出率CADe组56.5% vs 对照组45.5%。
- 平均腺瘤数CADe组1.48 vs 对照组0.86;非肿瘤性切除率CADe组52.1% vs 对照组35.0%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The effect of computer-aided polyp detection (CADe) on adenoma detection rate (ADR) among endoscopists-in-training remains unknown. METHODS: We performed a single-blind, parallel-group, randomized controlled trial in Hong Kong between April 2021 and July 2022 (NCT04838951). Eligible subjects undergoing screening/surveillance/diagnostic colonoscopies were randomized 1:1 to receive colonoscopies with CADe (ENDO-AID[OIP-1]) or not (control) during withdrawal. Procedures were performed by endoscopists-in-training with <500 procedures and <3 years' experience. Randomization was stratified by patient age, sex, and endoscopist experience (beginner vs intermediate level, <200 vs 200-500 procedures). Image enhancement and distal attachment devices were disallowed. Subjects with incomplete colonoscopies or inadequate bowel preparation were excluded. Treatment allocation was blinded to outcome assessors. The primary outcome was ADR. Secondary outcomes were ADR for different adenoma sizes and locations, mean number of adenomas, and non-neoplastic resection rate. RESULTS: A total of 386 and 380 subjects were randomized to CADe and control groups, respectively. The overall ADR was significantly higher in the CADe group than in the control group (57.5% vs 44.5%; adjusted relative risk, 1.41; 95% CI, 1.17-1.72; P < .001). The ADRs for <5 mm (40.4% vs 25.0%) and 5- to 10-mm adenomas (36.8% vs 29.2%) were higher in the CADe group. The ADRs were higher in the CADe group in both the right colon (42.0% vs 30.8%) and left colon (34.5% vs 27.6%), but there was no significant difference in advanced ADR. The ADRs were higher in the CADe group among beginner (60.0% vs 41.9%) and intermediate-level (56.5% vs 45.5%) endoscopists. Mean number of adenomas (1.48 vs 0.86) and non-neoplastic resection rate (52.1% vs 35.0%) were higher in the CADe group. CONCLUSIONS: Among endoscopists-in-training, the use of CADe during colonoscopies was associated with increased overall ADR. (ClinicalTrials.gov, Number: NCT04838951).
引用
- Lau LHS, Ho JCL, Lai JCT, et al. Effect of Real-Time Computer-Aided Polyp Detection System (ENDO-AID) on Adenoma Detection in Endoscopists-in-Training: A Randomized Trial. Clin Gastroenterol Hepatol. 2023. PMID: 37918685. doi:10.1016/j.cgh.2023.10.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。