内镜下手工缝合联合夹闭策略关闭内镜黏膜下剥离术伴或不伴肌层切除术后直肠缺损(含视频)
本研究为观察性研究,回顾性分析49例直肠缺损(42例ESD缺损和7例ESD-ME缺损)采用EHS-Clips策略关闭的数据,全部缺损完全闭合,无迟发出血,术后3-5天持续闭合率73.5%。多因素分析显示缝合边距≥5 mm是持续闭合的唯一独立有利因素。
要点
- EHS-Clips策略使49例直肠缺损全部完全闭合,其中71.4%单纯EHS完成,28.6%需追加夹闭。
- 无患者发生迟发出血。
- 缝合边距≥5 mm与持续闭合独立相关(HR 0.313,95%CI 0.023-0.781,P=.009)。
核心结论
- EHS-Clips可有效关闭ESD或ESD-ME后的直肠缺损并预防迟发出血。
- 缝合边距≥5 mm的完全缝合可能实现更可靠的持续闭合。
研究设计与样本
- 观察性研究,回顾性分析采用EHS-Clips关闭直肠缺损的患者数据。
- 共49例直肠缺损,包括42例ESD缺损和7例ESD-ME缺损。
- EHS-Clips策略指先尽可能通过EHS缝合缺损,无法完全缝合的剩余部分使用夹闭。
- 主要终点包括完全闭合率、迟发出血率和持续闭合率。
- 采用逻辑回归分析识别持续闭合的危险因素。
主要发现
- 全部49例(100%)缺损完全闭合,其中35例(71.4%)单纯通过EHS完成,14例(28.6%)通过EHS追加夹闭完成。
- 无患者发生迟发出血。
- 术后第3至5天,36例(73.5%)缺损保持持续闭合(ESD缺损为73.8% vs ESD-ME缺损为71.4%)。
- 多因素分析显示,缝合边距≥5 mm是持续闭合的唯一独立有利因素(风险比0.313,95%置信区间0.023-0.781,P=.009)。
关键数值与推荐
- 完全闭合率:49/49(100%)。
- 迟发出血率:0例患者发生迟发出血。
- 持续闭合率:36/49(73.5%);ESD缺损73.8% vs ESD-ME缺损71.4%。
- 缝合边距≥5 mm与持续闭合独立相关:风险比0.313(95%置信区间0.023-0.781,P=.009)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Endoscopic hand-suturing (EHS) has been preliminarily demonstrated to be effective in closing defects after endoscopic submucosal dissection (ESD), but it is not easily performed. We proposed a strategy combining EHS with clips (EHS-Clips) and explored its effectiveness in closing rectal defects after ESD or ESD with myectomy (ESD-ME). METHODS: In this observational study, data from patients with rectal defects closed using EHS-Clips were reviewed. EHS-Clips refers to a strategy where defects are sutured as much as possible by EHS first, with clips being used to close the remaining parts of defects that cannot be completely sutured. The primary endpoints included complete closure rate, delayed bleeding (DB) rate, and sustained closure rate. Logistic regression analyses were performed to identify risk factors for the sustained closure. RESULTS: All 49 (100%) defects (42 ESD defects and 7 ESD-ME defects) were completely closed through the strategy of EHS-Clips, with 35 (71.4%) through EHS alone and 14 (28.6%) through EHS and additional clips. No patients experienced DB. Thirty-six (73.5%) defects remained sustained closure on postoperative days 3 to 5 (73.8% for ESD defects vs 71.4% for ESD-ME defects). The multivariate analyses identified a stitch margin of ≥5 mm (hazard ratio, 0.313; 95% confidence interval, 0.023-0.781; P = .009) as the only independent advantage factor for the sustained closure. CONCLUSIONS: EHS-Clips can be used to effectively close the rectal defects after ESD or ESD-ME and prevent DB. Complete suture with a stitch margin of ≥5 mm may achieve more reliable sustained closure.
引用
- Song S, Dou L, Liu Y, et al. A strategy combining endoscopic hand-suturing with clips for closure of rectal defects after endoscopic submucosal dissection with or without myectomy (with video). Gastrointest Endosc. 2023. PMID: 37993061. doi:10.1016/j.gie.2023.11.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。