纹理与色彩增强成像对比窄带成像对右半结肠额外30秒观察漏诊息肉的随机试验
本研究纳入381例≥40岁接受结肠镜检查的患者,随机分入TXI组或NBI组,右半结肠先以白光观察,再追加30秒TXI或NBI观察。追加观察中TXI组每例平均腺瘤及无蒂锯齿状病变数为0.29(51/177),NBI组为0.30(54/181),非劣效性显著(P<0.01);两组右半结肠腺瘤检出率等变化无显著差异。
要点
- 右半结肠追加30秒TXI观察在检出漏诊息肉方面非劣效于NBI。
- 追加观察中TXI组每例平均腺瘤及无蒂锯齿状病变数为0.29(51/177),NBI组为0.30(54/181)。
- 两组右半结肠腺瘤检出率、腺瘤及无蒂锯齿状病变检出率、息肉检出率的变化无显著差异。
核心结论
- 对右半结肠进行额外30秒观察时,TXI在检出漏诊息肉方面非劣效于NBI。
研究设计与样本
- 多机构随机对照试验,2021年9月至2022年6月纳入381例≥40岁接受结肠镜检查的患者,随机分入TXI组或NBI组。
- 两组右半结肠均先以白光成像观察,再从肝曲重新插入至盲肠,分别以TXI或NBI追加30秒观察。
- 主要终点为每例患者平均腺瘤及无蒂锯齿状病变数的非劣效性,次要终点包括两组腺瘤检出率、腺瘤及无蒂锯齿状病变检出率、息肉检出率。
主要发现
- TXI组177例,NBI组181例;追加观察中每例平均腺瘤及无蒂锯齿状病变数TXI组为0.29(51/177),NBI组为0.30(54/181),非劣效性显著(P<0.01)。
- 两组右半结肠腺瘤检出率变化为10.2% vs 10.5%(P=0.81),无显著差异。
- 两组右半结肠腺瘤及无蒂锯齿状病变检出率变化为13.0% vs 12.7%(P=0.71),无显著差异。
- 两组右半结肠息肉检出率变化为15.3% vs 13.8%(P=0.71),无显著差异。
关键数值与推荐
- 非劣效性判定基于每例患者平均腺瘤及无蒂锯齿状病变数:TXI组0.29(51/177) vs NBI组0.30(54/181),P<0.01。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The efficacy of texture and color enhancement imaging (TXI) in the novel light-emitting diode endoscopic system for polyp detection has not been examined. We aimed to evaluate the noninferiority of the additional 30-second (Add-30-s) observation of the right-sided colon (cecum/ascending colon) with TXI compared with narrow band imaging (NBI) for detecting missed polyps. METHODS: We enrolled 381 patients ≥40 years old who underwent colonoscopy from September 2021 to June 2022 in 3 institutions and randomly assigned them to either the TXI or NBI groups. The right-sided colon was first observed with white light imaging in both groups. Second, after reinsertion from hepatic flexure to the cecum, the right-sided colon was observed with Add-30-s observation of either TXI or NBI. The primary endpoint was to examine the noninferiority of TXI to NBI using the mean number of adenomas and sessile serrated lesions per patient. The secondary ones were to examine adenoma detection rate, adenoma and sessile serrated lesions detection rates, and polyp detection rates in both groups. RESULTS: The TXI and NBI groups consisted of 177 and 181 patients, respectively, and the noninferiorities of the mean number of adenomas and sessile serrated lesions per patients in the second observation were significant (TXI 0.29 [51/177] vs NBI 0.30 [54/181], P < 0.01). The change in adenoma detection rate, adenoma and sessile serrated lesions detection rate, and polyp detection rate for the right-sided colon between the TXI and NBI groups were not different (10.2%/10.5% [ P = 0.81], 13.0%/12.7% [ P = 0.71], and 15.3%/13.8% [ P = 0.71]), respectively. DISCUSSION: Regarding Add-30-s observation of the right-sided colon, TXI was noninferior to NBI.
引用
- Yoshida N, Inagaki Y, Inada Y, et al. Additional 30-Second Observation of the Right-Sided Colon for Missed Polyp Detection With Texture and Color Enhancement Imaging Compared with Narrow Band Imaging: A Randomized Trial. Am J Gastroenterol. 2023. PMID: 37782280. doi:10.14309/ajg.0000000000002529
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。