人工智能辅助实时监测结肠镜检查有效退镜时间:一种新的结肠镜检查质量标志物
本研究纳入350段结肠镜退镜(从盲肠到肛门)视频,用人工智能(AI)模型量化有效退镜时间(EWT),并与标准退镜时间(SWT)比较。按EWT五分位从低到高,粗腺瘤检出率(ADR)分别为10.0%、31.4%、33.3%、53.5%和85.7%;EWT每增加1分钟,ADR增加49%(aOR 1.49,95%CI 1.36-1.65),且EWT预测腺瘤检出的曲线下面积显著高于SWT(.80 vs .70,P < .01)。
要点
- EWT五分位从低到高,粗ADR依次为10.0%、31.4%、33.3%、53.5%和85.7%。
- EWT每增加1分钟,ADR增加49%(aOR 1.49,95%CI 1.36-1.65)。
- EWT预测腺瘤检出的AUC为.80,高于SWT的.70(P < .01)。
核心结论
- AI衍生的EWT监测是一种有前景的结肠镜新质量指标,其与ADR的关联强于SWT。
研究设计与样本
- 研究评估了350段结肠镜退镜(从盲肠到肛门)视频录像,由新AI模型进行分析。
- 主要结局为按EWT不同五分位分组的腺瘤检出率(ADR)。
- 采用多因素logistic回归调整基线协变量,以最低五分位为参照,计算EWT对病变检出率的调整比值比(OR)。
- 比较EWT与SWT的受试者工作特征曲线下面积。
主要发现
- EWT五分位从低到高,粗ADR分别为10.0%、31.4%、33.3%、53.5%和85.7%。
- 与最低五分位相比,最高4个五分位检出腺瘤和息肉的OR均显著更高。
- EWT每增加1分钟,ADR增加49%(aOR 1.49;95%CI 1.36-1.65)。
- EWT预测腺瘤检出的AUC为.80(95%CI .75-.84),显著高于SWT的.70(95%CI .64-.74),P < .01。
关键数值与推荐
- EWT五分位从低到高,粗ADR分别为10.0%、31.4%、33.3%、53.5%和85.7%。
- 与最低五分位相比,最高4个五分位检出腺瘤和息肉的OR均显著更高。
- EWT每增加1分钟,ADR增加49%(aOR 1.49;95%CI 1.36-1.65)。
- EWT预测腺瘤检出的AUC为.80(95%CI .75-.84),SWT为.70(95%CI .64-.74),P < .01。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: The importance of withdrawal time during colonoscopy cannot be overstated in mitigating the risk of missed lesions and postcolonoscopy colorectal cancer. We evaluated a novel colonoscopy quality metric called the effective withdrawal time (EWT), which is an artificial intelligence (AI)-derived quantitative measure of quality withdrawal time, and its association with various colonic lesion detection rates as compared with standard withdrawal time (SWT). METHODS: Three hundred fifty video recordings of colonoscopy withdrawal (from the cecum to the anus) were assessed by the new AI model. The primary outcome was adenoma detection rate (ADR) according to different quintiles of EWT. Multivariate logistic regression, adjusting for baseline covariates, was used to determine the adjusted odd ratios (ORs) for EWT on lesion detection rates, with the lowest quintile as reference. The area under the receiver-operating characteristic curve of EWT was compared with SWT. RESULTS: The crude ADR in different quintiles of EWT, from lowest to highest, was 10.0%, 31.4%, 33.3%, 53.5%, and 85.7%. The ORs of detecting adenomas and polyps were significantly higher in all top 4 quintiles when compared with the lowest quintile. Each minute increase in EWT was associated with a 49% increase in ADR (aOR, 1.49; 95% confidence interval [CI], 1.36-1.65). The area under the receiver-operating characteristic curve of EWT was also significantly higher than SWT on adenoma detection (.80 [95% CI, .75-.84] vs .70 [95% CI, .64-.74], P < .01). CONCLUSIONS: AI-derived monitoring of EWT is a promising novel quality indicator for colonoscopy, which is more associated with ADR than SWT.
引用
- Lui TKL, Ko MKL, Liu JJ, et al. Artificial intelligence-assisted real-time monitoring of effective withdrawal time during colonoscopy: a novel quality marker of colonoscopy. Gastrointest Endosc. 2023. PMID: 37858761. doi:10.1016/j.gie.2023.10.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。