可切除肝门部胆管癌术前内镜胆道引流:金属支架与塑料支架的比较
这项多中心国际回顾性队列研究纳入2010至2020年接受初始内镜术前胆道引流的可切除肝门部胆管癌患者474例,其中金属支架组61例、塑料支架组413例,倾向性评分匹配后每组各59例。金属支架组支架失败率显著低于塑料支架组(31% vs 64%,P < .001),术后胆管炎更少(15% vs 31%,P = .012),两组手术切除率无显著差异(46% vs 49%,P = .71),术中支架取出均成功且无不良事件。
要点
- 匹配后金属支架组支架失败率31%,塑料支架组64%,差异有统计学意义(P < .001)。
- 金属支架组胆管炎发生率15%,塑料支架组31%(P = .012);其他引流相关不良事件两组无差异。
- 两组手术切除率无显著差异(46% vs 49%,P = .71),术中金属支架取出均成功且无不良事件。
核心结论
- 在可切除肝门部胆管癌患者中,使用金属支架行术前胆道引流的支架失败率低于塑料支架,术中取出可行,手术结局相似。
研究设计与样本
- 多中心国际回顾性队列研究,纳入2010至2020年接受初始内镜术前胆道引流的潜在可切除肝门部胆管癌患者。
- 共474例患者成功置入支架,其中金属支架组61例、塑料支架组413例;倾向性评分匹配(1:1)后每组各59例。
主要发现
- 匹配后金属支架组支架失败率为31%,塑料支架组为64%,差异有统计学意义(P < .001)。
- 金属支架组置入后胆管炎发生率为15%,塑料支架组为31%(P = .012);其他引流相关不良事件两组无差异。
- 两组接受手术切除的患者比例无显著差异(46% vs 49%,P = .71)。
- 术中完全取出金属支架在所有患者中均成功且无不良事件。
关键数值与推荐
- 支架失败定义为胆管炎或因不良事件或引流不充分而再次干预的复合终点。
- 匹配后金属支架组支架失败率31% vs 塑料支架组64%(P < .001)。
- 匹配后金属支架组胆管炎发生率15% vs 塑料支架组31%(P = .012)。
- 匹配后金属支架组手术切除率46% vs 塑料支架组49%(P = .71)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Adequate preoperative biliary drainage (PBD) is recommended in most patients with resectable perihilar cholangiocarcinoma (pCCA). Most expert centers use endoscopic plastic stents rather than self-expandable metal stents (SEMSs). In the palliative setting, however, use of SEMSs has shown longer patency and superior survival. The aim of this retrospective study was to compare stent dysfunction of SEMSs versus plastic stents for PBD in resectable pCCA patients. METHODS: In this multicenter international retrospective cohort study, patients with potentially resectable pCCAs who underwent initial endoscopic PBD from 2010 to 2020 were included. Stent failure was a composite end point of cholangitis or reintervention due to adverse events or insufficient PBD. Other adverse events, surgical outcomes, and survival were recorded. Propensity score matching (PSM) was performed on several baseline characteristics. RESULTS: A total of 474 patients had successful stent placement, of whom 61 received SEMSs and 413 plastic stents. PSM (1:1) resulted in 2 groups of 59 patients each. Stent failure occurred significantly less in the SEMSs group (31% vs 64%; P < .001). Besides less cholangitis after SEMSs placement (15% vs 31%; P = .012), other PBD-related adverse events did not differ. The number of patients undergoing surgical resection was not significantly different (46% vs 49%; P = .71). Complete intraoperative SEMSs removal was successful and without adverse events in all patients. CONCLUSIONS: Stent failure was lower in patients with SEMSs as PBD compared with plastic stents in patients with resectable pCCA. Removal during surgery was quite feasible. Surgical outcomes were similar.
引用
- de Jong DM, Gilbert TM, Nooijen LE, et al. Preoperative endoscopic biliary drainage by metal versus plastic stents for resectable perihilar cholangiocarcinoma. Gastrointest Endosc. 2023. PMID: 37866710. doi:10.1016/j.gie.2023.10.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。