文献速递炎症性肠病消化内镜

马达化螺旋小肠镜与单气囊小肠镜在疑似克罗恩病中的技术性能与诊断率比较:一项随机对照开放标签研究(MOTOR-CD试验)

Technical performance and diagnostic yield of motorised spiral enteroscopy compared with single-balloon enteroscopy in suspected Crohn's disease: a randomised controlled, open-label study (the MOTOR-CD trial).
PubMed 文献 · Gut · 2023-05-17

该随机对照开放标签研究将125例疑似克罗恩病需小肠镜检查的患者随机分为马达化螺旋小肠镜(MSE)组62例和单气囊小肠镜(SBE)组63例,比较双向小肠镜的技术成功率、诊断率、最大插入深度、操作时间和全小肠镜检查率。总体技术成功率和诊断率两组无显著差异,但MSE在更深部小肠(远端空肠/近端回肠)的技术成功率有更高趋势,最大插入深度、深度时间比和尝试时的全小肠镜检查率均更高。

要点

  • MSE与SBE在疑似克罗恩病小肠评估中总体技术成功率和诊断率相当。
  • MSE在更深部小肠(远端空肠/近端回肠)技术成功率有更高趋势(96.8% vs 80.7%,p=0.08)。
  • MSE尝试时全小肠镜检查率更高(77.8% vs 11.1%,p=0.0007),且深度时间比更高。

核心结论

  • MSE与SBE在疑似克罗恩病小肠评估中具有可比的技术成功率和诊断率。
  • MSE在更深部小肠评估、全小肠覆盖和更短时间内更高插入深度方面优于SBE。

研究设计与样本

  • 随机对照开放标签研究,于2022年5月至2022年9月在一家高容量三级中心进行。
  • 125例疑似克罗恩病需小肠镜检查的患者随机接受MSE(62例)或SBE(63例)。
  • 若单向检查未到达目标病灶则进行双向小肠镜,比较技术成功、诊断率、最大插入深度、操作时间和全小肠镜检查率。

主要发现

  • 总体技术成功率:MSE 98.4% vs SBE 90.5%(p=0.11),无显著差异。
  • 诊断率:MSE 95.2% vs SBE 87.3%(p=0.2),无显著差异。
  • 更深部小肠(远端空肠/近端回肠)技术成功率:MSE 96.8% vs SBE 80.7%(p=0.08)。
  • 尝试时全小肠镜检查率:MSE 77.8% vs SBE 11.1%(p=0.0007),MSE更高。
  • 两种方法均安全,但MSE轻微不良事件更常见。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Recent studies have shown that motorised spiral enteroscopy (MSE) enables deeper and total small bowel evaluation compared with single-balloon enteroscopy (SBE) in suspected Crohn's disease (CD) when analysed per procedure. However, no randomised controlled study has compared bidirectional MSE with bidirectional SBE in suspected CD. DESIGN: Patients with suspected CD requiring small bowel enteroscopy were randomly assigned to either SBE or MSE between May 2022 and September 2022 in a high volume tertiary centre. Bidirectional enteroscopy was done if intended lesion could not be reached on unidirectional study. Comparison was made with regard to technical success (ability to reach lesion), diagnostic yield, depth of maximal insertion (DMI), procedure time and total enteroscopy rates. Depth:time ratio was calculated to avoid confounding for the location of lesion. RESULTS: Among 125 suspected patients with CD (28% female, 18-65 years, median 41 years), 62 and 63 underwent MSE and SBE, respectively. The overall technical success (98.4 %: MSE, 90.5 %: SBE; p=0.11), diagnostic yield (95.2%: MSE; 87.3%: SBE, p=0.2) and procedure time were not significantly different. However, MSE appeared to have higher technical success (96.8% vs 80.7%, p=0.08) in deeper small bowel (distal jejunum/proximal ileum) with higher DMI, higher depth:time ratio and total enteroscopy rates when attempted (77.8% vs 11.1%, p=0.0007). Both the modalities were safe although minor adverse events were more common with MSE. CONCLUSION: MSE and SBE have comparable technical success and diagnostic yield for small bowel evaluation in suspected CD. MSE scores over SBE with regard to deeper small bowel evaluation with complete small bowel coverage and higher depth of insertion in a shorter time. TRIAL REGISTRATION NUMBER: NCT05363930.

来源:Gut,查看原文。版权归原作者所有。

引用

  1. Pal P, Ramchandani M, Banerjee R, et al. Technical performance and diagnostic yield of motorised spiral enteroscopy compared with single-balloon enteroscopy in suspected Crohn's disease: a randomised controlled, open-label study (the MOTOR-CD trial). Gut. 2023. PMID: 37197904. doi:10.1136/gutjnl-2023-329885

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。