文献速递肝病

基于磁共振弹性成像的肝脏硬度、脂肪分数与T1弛豫时间识别高危NASH的头对头比较

Head-to-head comparison of magnetic resonance elastography-based liver stiffness, fat fraction, and T1 relaxation time in identifying at-risk NASH.
PubMed 文献 · Hepatology · 2023-05-01

该前瞻性临床试验纳入104对疑似或确诊NAFLD患者的MR检查与肝活检,比较磁共振弹性成像肝脏硬度、Dixon质子密度脂肪分数和T1弛豫时间识别高危NASH的性能。肝脏硬度诊断高危NASH的AUC最高,为0.89,最佳截断值3.3 kPa(敏感度79%、特异度82%、阴性预测值91%);PDFF诊断任何纤维化分期NASH的AUC最高,为0.82。结论认为肝脏硬度单独优于PDFF和T1。

要点

  • 肝脏硬度诊断高危NASH的AUC为0.89,显著高于PDFF的0.70和T1的0.72。
  • 肝脏硬度识别高危NASH的最佳截断值为3.3 kPa,敏感度79%、特异度82%、阴性预测值91%。
  • PDFF诊断任何纤维化分期NASH的AUC最高,为0.82。

核心结论

  • 磁共振弹性成像评估的肝脏硬度单独在识别高危NASH方面优于PDFF和T1。

研究设计与样本

  • 前瞻性临床试验(NCT02565446),纳入104对疑似或确诊NAFLD患者的MR检查与肝活检。

主要发现

  • 肝脏硬度诊断高危NASH的AUC为0.89(0.82,0.95),PDFF为0.70(0.58,0.81),T1为0.72(0.61,0.82),肝脏硬度与其他指标比较的z-score检验z>1.96。
  • 肝脏硬度识别高危NASH的最佳截断值为3.3 kPa,敏感度79%、特异度82%、阴性预测值91%。
  • T1识别高危NASH的最佳截断值为850 ms,敏感度75%、特异度63%、阴性预测值87%。
  • PDFF诊断任何纤维化分期NASH的AUC为0.82(0.72,0.91),肝脏硬度为0.73(0.63,0.84),T1为0.72(0.61,0.83),所有比较|z|<1.96。

关键数值与推荐

  • 肝脏硬度诊断高危NASH的AUC为0.89(0.82,0.95)。
  • PDFF诊断高危NASH的AUC为0.70(0.58,0.81)。
  • T1诊断高危NASH的AUC为0.72(0.61,0.82)。
  • 肝脏硬度识别高危NASH的最佳截断值为3.3 kPa(敏感度79%、特异度82%、阴性预测值91%)。
  • T1识别高危NASH的最佳截断值为850 ms(敏感度75%、特异度63%、阴性预测值87%)。

临床怎么用

  • 原文未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: The presence of at-risk NASH is associated with an increased risk of cirrhosis and complications. Therefore, noninvasive identification of at-risk NASH with an accurate biomarker is a critical need for pharmacologic therapy. We aim to explore the performance of several magnetic resonance (MR)-based imaging parameters in diagnosing at-risk NASH. APPROACH AND RESULTS: This prospective clinical trial (NCT02565446) includes 104 paired MR examinations and liver biopsies performed in patients with suspected or diagnosed NAFLD. Magnetic resonance elastography-assessed liver stiffness (LS), 6-point Dixon-derived proton density fat fraction (PDFF), and single-point saturation-recovery acquisition-calculated T1 relaxation time were explored. Among all predictors, LS showed the significantly highest accuracy in diagnosing at-risk NASH [AUC LS : 0.89 (0.82, 0.95), AUC PDFF : 0.70 (0.58, 0.81), AUC T1 : 0.72 (0.61, 0.82), z -score test z >1.96 for LS vs any of others]. The optimal cutoff value of LS to identify at-risk NASH patients was 3.3 kPa (sensitivity: 79%, specificity: 82%, negative predictive value: 91%), whereas the optimal cutoff value of T1 was 850 ms (sensitivity: 75%, specificity: 63%, and negative predictive value: 87%). PDFF had the highest performance in diagnosing NASH with any fibrosis stage [AUC PDFF : 0.82 (0.72, 0.91), AUC LS : 0.73 (0.63, 0.84), AUC T1 : 0.72 (0.61, 0.83), |z| <1.96 for all]. CONCLUSION: Magnetic resonance elastography-assessed LS alone outperformed PDFF, and T1 in identifying patients with at-risk NASH for therapeutic trials.

来源:Hepatology,查看原文。版权归原作者所有。

引用

  1. Li J, Lu X, Zhu Z, et al. Head-to-head comparison of magnetic resonance elastography-based liver stiffness, fat fraction, and T1 relaxation time in identifying at-risk NASH. Hepatology. 2023. PMID: 37080558. doi:10.1097/HEP.0000000000000417

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。