文献速递消化内镜消化道肿瘤与早癌

放大色素内镜联合放大窄带成像内镜对结直肠息肉的诊断价值

Diagnostic Value of Adding Magnifying Chromoendoscopy to Magnifying Narrow-Band Imaging Endoscopy for Colorectal Polyps.
PubMed 文献 · Clin Gastroenterol Hepatol · 2023-02-03

本研究为在日本和德国9家机构开展的多中心前瞻性研究,纳入2018年2月至2020年12月的1173个结直肠息肉病变,先以放大窄带成像内镜(M-NBI)实时诊断,再行放大色素内镜(MCE),比较两者预测深浸润结直肠癌(≥T1b)的准确性。MCE敏感度显著高于M-NBI(77.4% vs 63.1%,P < .001),但附加价值仅限于M-NBI低置信度或M-NBI诊断为≥T1b的病变。

要点

  • MCE对深浸润结直肠癌的敏感度为77.4%,显著高于M-NBI的63.1%(P < .001)。
  • MCE的附加价值仅限于M-NBI低置信度或M-NBI诊断为≥T1b的病变。
  • 作者建议对M-NBI低置信度或诊断为≥T1b的病变加做MCE。

核心结论

  • 本多中心前瞻性研究证实MCE对M-NBI具有附加诊断价值,作者建议对M-NBI低置信度或诊断为≥T1b的病变加做MCE。

研究设计与样本

  • 多中心前瞻性研究,在日本和德国9家机构开展,纳入拟切除的结直肠息肉患者,共1173个病变,其中654个在M-NBI后行MCE检查。

主要发现

  • M-NBI预测深浸润结直肠癌的敏感度、特异度、阳性预测值、阴性预测值和准确度分别为63.1%、94.2%、61.6%、94.5%和90.2%。
  • MCE预测深浸润结直肠癌的敏感度、特异度、阳性预测值、阴性预测值和准确度分别为77.4%、93.2%、62.5%、96.5%和91.1%。
  • MCE敏感度显著高于M-NBI(P < .001)。
  • MCE的附加价值仅限于M-NBI低置信度或M-NBI诊断为≥T1b的病变。

临床怎么用

  • 作者建议对M-NBI低置信度或M-NBI诊断为≥T1b的病变加做MCE。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: This study examined the additional value of magnifying chromoendoscopy (MCE) on magnifying narrow-band imaging endoscopy (M-NBI) in the optical diagnosis of colorectal polyps. METHODS: A multicenter prospective study was conducted at 9 facilities in Japan and Germany. Patients with colorectal polyps scheduled for resection were included. Optical diagnosis was performed by M-NBI first, followed by MCE. Both diagnoses were made in real time. MCE was performed on all type 2B lesions classified according to the Japan NBI Expert Team classification and other lesions at the discretion of endoscopists. The diagnostic accuracy and confidence of M-NBI and MCE for colorectal cancer (CRC) with deep invasion (≥T1b) were compared on the basis of histologic findings after resection. RESULTS: In total, 1173 lesions were included between February 2018 and December 2020, with 654 (5 hyperplastic polyp/sessile serrated lesion, 162 low-grade dysplasia, 403 high-grade dysplasia, 97 T1 CRCs, and 32 ≥T2 CRCs) examined using MCE after M-NBI. In the diagnostic accuracy for predicting CRC with deep invasion, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for M-NBI were 63.1%, 94.2%, 61.6%, 94.5%, and 90.2%, respectively, and for MCE they were 77.4%, 93.2%, 62.5%, 96.5%, and 91.1%, respectively. The sensitivity was significantly higher in MCE (P < .001). However, these additional values were limited to lesions with low confidence in M-NBI or the ones diagnosed as ≥T1b CRC by M-NBI. CONCLUSIONS: In this multicenter prospective study, we demonstrated the additional value of MCE on M-NBI. We suggest that additional MCE be recommended for lesions with low confidence or the ones diagnosed as ≥T1b CRC. Trials registry number: UMIN000031129.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Matsumura T, Ebigbo A, Römmele C, et al. Diagnostic Value of Adding Magnifying Chromoendoscopy to Magnifying Narrow-Band Imaging Endoscopy for Colorectal Polyps. Clin Gastroenterol Hepatol. 2023. PMID: 36739935. doi:10.1016/j.cgh.2023.01.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。