缝合20毫米腔壁贴合金属支架使Roux-en-Y胃旁路术后患者可安全接受同次超声内镜引导下经胃干预:一项多中心研究(附视频)
本研究为两中心回顾性研究,纳入2018年2月至2020年5月连续37例Roux-en-Y胃旁路术后患者,评估使用内镜缝合固定的20毫米腔壁贴合金属支架行同次超声内镜引导下经胃干预的安全性和有效性。技术成功率100%,不良事件发生率10.8%,无支架移位,持续性瘘发生率18.9%但可经内镜处理。
要点
- 缝合固定的20毫米腔壁贴合金属支架行同次超声内镜引导下经胃干预技术成功率达100%。
- 不良事件发生率为10.8%(4例),无支架移位或迟发性支架迁移发生。
- 持续性瘘发生率为18.9%(7例),其中6例经内镜成功闭合。
核心结论
- 使用缝合固定的20毫米腔壁贴合金属支架行单阶段超声内镜引导下经胃干预技术成功率高、不良事件发生率低,且无支架迁移发生。
- 持续性瘘虽常见,但可经内镜处理。
研究设计与样本
- 两中心回顾性研究,纳入2018年2月至2020年5月连续接受缝合固定20毫米腔壁贴合金属支架行同次超声内镜引导下经胃干预的Roux-en-Y胃旁路术后患者37例。
- 记录患者人口学特征、操作细节和临床结局。
主要发现
- 37例患者平均年龄58.1岁,女性占86.5%,中位随访31.8个月。
- 操作类型为内镜逆行胰胆管造影33例(89.2%),内镜逆行胰胆管造影联合超声内镜4例(10.8%)。
- 技术成功率为100%;经胃胃瘘通路26例(70.3%),经胃空肠瘘通路11例(29.7%)。
- 支架以2枚内镜缝线固定33例(89.2%),以1枚缝线固定4例(10.8%)。
- 不良事件4例(10.8%),其中术后出血3例、胆管炎1例;无支架脱位或迟发性支架迁移发生。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: EUS-directed transgastric intervention (EDGI) is an established technique for the management of pancreaticobiliary pathology in Roux-en-Y gastric bypass (RYGB) patients. There is an inherent risk of intraprocedural stent dislodgement, leading to perforation. The procedure is therefore often performed in 2 stages, 2 to 4 weeks apart, to allow for fistula maturation to mitigate the risk of lumen-apposing metal stent (LAMS) dislodgment. However, some clinical indications such as cholangitis require more urgent intervention, rendering this approach impractical. The aim of this study was to evaluate the safety and efficacy of same-session (SS)-EDGI with fixation of a 20-mm LAMS using endoscopic suturing. METHODS: This was a 2-center, retrospective study of consecutive RYGB patients who underwent SS-EDGI using a sutured 20-mm LAMS between February 2018 and May 2020. Patient demographics, procedural details, and clinical outcomes were recorded. RESULTS: Thirty-seven patients (mean age, 58.1 years; 86.5% women) underwent SS-EDGI with a median follow-up of 31.8 months. The procedural intervention was ERCP in 33 patients (89.2%) and ERCP with EUS in 4 patients (10.8%). Technical success was 100%. Access was achieved through the gastrogastric fistula in 26 patients (70.3%) and the jejunogastric fistula in 11 (29.7%). The LAMS was anchored with 2 endoscopic sutures in 33 patients (89.2%) and 1 suture in 4 (10.8%). Adverse events occurred in 4 patients (10.8%; 3 postprocedural bleeding, 1 cholangitis). There were no episodes of stent dislodgement or delayed stent migration. A persistent fistula was diagnosed in 7 patients (18.9%) who underwent objective testing (n = 28, 75.7%), of which 6 were successfully closed endoscopically. CONCLUSIONS: Single-stage EDGI using a sutured 20-mm LAMS was associated with a high rate of technical success, low rates of adverse events, and no episodes of stent migration. Persistent fistulas, although common, were amenable to endoscopic management.
引用
- Keane MG, Higa JT, La Selva D, et al. Suturing a 20-mm lumen-apposing metal stent allows for safe same-session EUS-directed transgastric intervention in patients with Roux-en-Y gastric bypass anatomy: a multicenter study (with video). Gastrointest Endosc. 2022. PMID: 36220380. doi:10.1016/j.gie.2022.10.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。