文献速递胃肠动力与功能性疾病消化内镜

提高高分辨率食管测压对GERD诊断率:直腿抬高国际研究

Improving the Diagnostic Yield of High-Resolution Esophageal Manometry for GERD: The "Straight Leg-Raise" International Study.
PubMed 文献 · Clin Gastroenterol Hepatol · 2022-10-19

本研究前瞻性纳入持续GERD症状、停用PPI后行HRM及pH-阻抗或无线pH监测的成人患者,在HRM芝加哥4.0方案后行直腿抬高(SLR)动作。SLR有效者295例中115例(39%)AET大于6%;GERD组SLR时食管内压峰值显著高于AET小于6%组(29.7 vs 13.9 mm Hg,P < .001)。SLR时食管内压峰值较基线升高11 mm Hg为预测AET大于6%的最佳截断值(AUC 0.84,敏感度79%,特异度85%)。

要点

  • SLR动作在295例(81%)患者中有效,其中115例(39%)AET大于6%。
  • GERD组SLR时食管内压峰值29.7 mm Hg,显著高于AET小于6%组的13.9 mm Hg。
  • SLR时食管内压峰值较基线升高11 mm Hg可预测AET大于6%,AUC 0.84。

核心结论

  • SLR动作可预测异常AET,从而在怀疑GERD时提高HRM的诊断价值。

研究设计与样本

  • 前瞻性研究,纳入2021年7月至2022年3月期间持续GERD症状、停用PPI后行HRM及pH-阻抗或无线pH监测的成人患者。
  • 按HRM芝加哥4.0方案后,患者仰卧位单腿抬高45度持续5秒;腹腔内压升高50%时SLR视为有效。
  • 在基线及SLR时记录下食管括约肌上方5 cm处食管内压;GERD定义为AET大于6%。

主要发现

  • SLR在295例(81%)患者中有效,其中115例(39%)AET大于6%;食管裂孔疝(EGJ 2型或3型)见于135例(46%)患者。
  • 与AET小于6%患者相比,GERD组SLR时食管内压峰值显著更高(29.7 vs 13.9 mm Hg;P < .001)。
  • SLR时食管内压峰值较基线升高11 mm Hg为预测AET大于6%的最佳截断值(AUC 0.84;敏感度79%;特异度85%),无论是否存在食管裂孔疝。
  • 多变量分析显示,SLR时食管内压升高、EGJ收缩积分、EGJ 2型及EGJ 3型为AET大于6%的显著预测因素。

关键数值与推荐

  • GERD定义为AET大于6%。
  • SLR有效性标准为腹腔内压升高50%。
  • SLR时食管内压峰值较基线升高11 mm Hg为预测AET大于6%的最佳截断值(AUC 0.84;敏感度79%;特异度85%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND & AIMS: The straight leg raise (SLR) maneuver during high-resolution manometry (HRM) can assess esophagogastric junction (EGJ) barrier function by measuring changes in intraesophageal pressure (IEP) when intra-abdominal pressure is increased. We aimed to determine whether increased esophageal pressure during SLR predicts pathologic esophageal acid exposure time (AET). METHODS: Adult patients with persistent gastroesophageal reflux disease (GERD) symptoms undergoing HRM and pH-impedance or wireless pH study off proton pump inhibitor were prospectively studied between July 2021 and March 2022. After the HRM Chicago 4.0 protocol, patients were requested to elevate 1 leg at 45º for 5 seconds while supine. The SLR maneuver was considered effective when intra-abdominal pressure increased by 50%. IEPs were recorded 5 cm above the lower esophageal sphincter at baseline and during SLR. GERD was defined as AET greater than 6%. RESULTS: The SLR was effective in 295 patients (81%), 115 (39%) of whom had an AET greater than 6%. Hiatal hernia (EGJ type 2 or 3) was seen in 135 (46%) patients. Compared with patients with an AET less than 6%, peak IEP during SLR was significantly higher in the GERD group (29.7 vs 13.9 mm Hg; P < .001). Using receiver operating characteristic analysis, an increase of 11 mm Hg of peak IEP from baseline during SLR was the optimal cut-off value to predict an AET greater than 6% (area under the receiver operating characteristic curve, 0.84; sensitivity, 79%; and specificity, 85%), regardless of the presence of hiatal hernia. On multivariable analysis, an IEP pressure increase during the SLR maneuver, EGJ contractile integral, EGJ subtype 2, and EGJ subtype 3, were found to be significant predictors of AET greater than 6% CONCLUSIONS: The SLR maneuver can predict abnormal an AET, thereby increasing the diagnostic value of HRM when GERD is suspected. CLINICALTRIALS: gov ID: NCT04813029.

来源:Clin Gastroenterol Hepatol,查看原文。版权归原作者所有。

引用

  1. Siboni S, Kristo I, Rogers BD, et al. Improving the Diagnostic Yield of High-Resolution Esophageal Manometry for GERD: The "Straight Leg-Raise" International Study. Clin Gastroenterol Hepatol. 2022. PMID: 36270615. doi:10.1016/j.cgh.2022.10.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。