利用基于胆道镜的深度学习人工智能识别恶性胆道狭窄患者(附视频)
研究回顾了2012至2021年连续接受胆道镜检查的患者,开发并测试了卷积神经网络(CNN)模型,并在多中心保留测试集上将其与ERCP取样技术比较。CNN视频分析总体准确率(.906)显著高于刷检细胞学(.625,P = .04)或钳夹活检(.609,P = .03)。
要点
- CNN基于胆道镜图像分析可对胆道狭窄进行分类。
- CNN视频分析准确率(.906)显著高于刷检细胞学(.625,P = .04)和钳夹活检(.609,P = .03)。
- 恶性胆道狭窄最常见的图像特征为绒毛状黏膜/乳头状突起。
核心结论
- 仅使用胆道镜数据开发的CNN在胆道狭窄分类方面比传统基于ERCP的取样技术具有更高的准确率。
研究设计与样本
- 回顾性纳入2012至2021年连续接受胆道镜检查的患者,共154例,图像数据库包含2,388,439张静态图像。
- 开发并测试CNN,使用专家直接标注的胆道镜图像,随后应用于多中心保留的胆道镜视频测试集,并与ERCP取样技术直接比较。
主要发现
- CNN在模仿专家对高质量恶性图像标注的任务中表现良好,受试者工作特征曲线下面积为.941。
- CNN视频分析总体准确率为.906,显著高于刷检细胞学的.625(P = .04)。
- CNN视频分析总体准确率为.906,显著高于钳夹活检的.609(P = .03)。
- 遮挡块热图分析显示,恶性胆道狭窄最常见的图像特征是绒毛状黏膜/乳头状突起。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND AIMS: Accurately diagnosing malignant biliary strictures (MBSs) as benign or malignant remains challenging. It has been suggested that direct visualization and interpretation of cholangioscopy images provide greater accuracy for stricture classification than current sampling techniques (ie, brush cytology and forceps biopsy sampling) using ERCP. We aimed to develop a convolutional neural network (CNN) model capable of accurate stricture classification and real-time evaluation based solely on cholangioscopy image analysis. METHODS: Consecutive patients with cholangioscopy examinations from 2012 to 2021 were reviewed. A CNN was developed and tested using cholangioscopy images with direct expert annotations. The CNN was then applied to a multicenter, reserved test set of cholangioscopy videos. CNN performance was then directly compared with that of ERCP sampling techniques. Occlusion block heatmap analyses were used to evaluate and rank cholangioscopy features associated with MBSs. RESULTS: One hundred fifty-four patients with available cholangioscopy examinations were included in the study. The final image database comprised 2,388,439 still images. The CNN demonstrated good performance when tasked with mimicking expert annotations of high-quality malignant images (area under the receiver-operating characteristic curve, .941). Overall accuracy of CNN-based video analysis (.906) was significantly greater than that of brush cytology (.625, P = .04) or forceps biopsy sampling (.609, P = .03). Occlusion block heatmap analysis demonstrated that the most frequent image feature for an MBS was the presence of frond-like mucosa/papillary projections. CONCLUSIONS: This study demonstrates that a CNN developed using cholangioscopy data alone has greater accuracy for biliary stricture classification than traditional ERCP-based sampling techniques.
引用
- Marya NB, Powers PD, Petersen BT, et al. Identification of patients with malignant biliary strictures using a cholangioscopy-based deep learning artificial intelligence (with video). Gastrointest Endosc. 2022. PMID: 36007584. doi:10.1016/j.gie.2022.08.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。