针对性干预以减少胃肠内镜医疗废物
这项前瞻性四阶段研究测量某内镜单位废物碳足迹,并在团队教育及调整垃圾分类后评估效果。从阶段1到阶段3, regulated医疗废物(RMW)平均减少41.4%(p=0.010),总废物减少12.9%(p=0.155),二氧化碳当量(CO2e)减少31.6%(p=0.018),效果维持至干预后4个月。
要点
- 团队教育及调整垃圾分类可减少受管制医疗废物(RMW)并增加回收。
- 干预后CO2e排放减少31.6%,年均减少1665.6kgCO2e。
- 效果在干预后4个月仍维持,且未影响内镜工作量。
核心结论
- 在真实世界场景中实施可持续措施,实现了受管制医疗废物(RMW)减少和每日回收,并随时间维持,且未影响内镜生产力。
研究设计与样本
- 前瞻性四阶段研究:阶段1为4周观察审计,每日称重两类废物;阶段2为1周团队废物处理教育干预,在内镜室放置回收箱并重新安置填埋与RMW垃圾桶;阶段3(干预后1个月)和阶段4(干预后4个月)每日称重内镜废物。
- 假设1kg填埋废物等于1kg二氧化碳当量(CO2e),1kg RMW等于3kgCO2e,采用配对样本t检验进行比较。
主要发现
- 从阶段1到阶段3,平均总废物减少12.9%(p=0.155),平均RMW减少41.4%(p=0.010)。
- 填埋废物增加(p=0.059),回收废物增加(纸张:p=0.001;塑料:p=0.007)。
- 平均内镜工作量相似(46.2 vs 44.5,p=0.275),CO2e总量减少31.6%(138.8kgCO2e),平均kgCO2e为109.7 vs 74.9(p=0.018)。
- 年减少量计算为1665.6kgCO2e。
- 所有效果在干预后4个月(阶段4)仍维持,且未遭负责内镜人员反对。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Endoscopy is healthcare's third largest generator of medical waste in hospitals. This prospective study aimed to measure a single unit's waste carbon footprint and perform a pioneer intervention towards a more sustainable endoscopy practice. The relation of regulated medical waste (RMW; material fully contaminated with blood or body fluids or containing infectious agents) versus landfill waste (non-recyclable material not fully contaminated) may play a critical role. DESIGN: In a four-stage prospective study, following a 4-week observational audit with daily weighing of both waste types (stage 1), stage 2 consisted of a 1-week intervention with team education of waste handling. Recycling bins were placed in endoscopy rooms, landfill and RMW bins were relocated. During stages 3 (1 month after intervention) and 4 (4 months after intervention), daily endoscopic waste was weighed. Equivalence of 1 kg of landfill waste to 1 kg carbon dioxide equivalent (CO2e) and 1 kg of RMW to 3kgCO2e was assumed. Paired samples t-tests for comparisons. RESULTS: From stage 1 to stage 3, mean total waste and RMW were reduced by 12.9% (p=0.155) and 41.4% (p=0.010), respectively, whereas landfill (p=0.059) and recycling waste increased (paper: p=0.001; plastic: p=0.007). While mean endoscopy load was similar (46.2 vs 44.5, p=0.275), a total decrease of CO2e by 31.6% (138.8kgCO2e) was found (mean kgCO2e109.7 vs 74.9, p=0.018). The annual reduction was calculated at 1665.6kgCO2e. All these effects were sustained 4 months after the intervention (stage 4) without objections by responsible endoscopy personnel. CONCLUSION: In this interventional study, applying sustainability measures to a real-world scenario, RMW reduction and daily recycling were achieved and sustained over time, without compromising endoscopy productivity.
引用
- Cunha Neves JA, Roseira J, Queirós P, et al. Targeted intervention to achieve waste reduction in gastrointestinal endoscopy. Gut. 2022. PMID: 35985798. doi:10.1136/gutjnl-2022-327005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。