文献速递炎症性肠病消化内镜

卷积神经网络对溃疡性结肠炎内镜严重程度分类具有高准确率

High Accuracy in Classifying Endoscopic Severity in Ulcerative Colitis Using Convolutional Neural Network.
PubMed 文献 · Am J Gastroenterol · 2022-07-15

最终模型在区分全部四类MES时测试准确率为0.84,在MES 0 vs 1-3和0-1 vs 2-3的二分类任务中准确率分别为0.94和0.93,受试者工作特征曲线下面积分别为0.997和0.998。

要点

  • 最终模型区分全部四类MES的测试准确率为0.84。
  • 二分类MES 0 vs 1-3准确率0.94,AUC 0.997。
  • 二分类MES 0-1 vs 2-3准确率0.93,AUC 0.998。

核心结论

  • 研究开发了一种高准确率、自动评估溃疡性结肠炎患者内镜图像的新方法,深度学习模型能够区分全部4个MES活动度等级。

研究设计与样本

  • 考虑多种卷积神经网络用于自动分类溃疡性结肠炎严重程度,采用五折交叉验证开发与选择最终模型,随后用未见测试数据集评估模型。

主要发现

  • 最终模型在区分全部MES类别的任务中测试准确率为0.84。
  • 模型在MES 0 vs 1-3的二分类任务中准确率为0.94,AUC为0.997。
  • 模型在MES 0-1 vs 2-3的二分类任务中准确率为0.93,AUC为0.998。

临床怎么用

  • 作者认为这种新的自动方法可能优化和标准化各中心按MES测量的疾病严重程度评估,而不论医疗专业水平如何。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The evaluation of endoscopic disease severity is a crucial component in managing patients with ulcerative colitis (UC). However, endoscopic assessment suffers from substantial intraobserver and interobserver variations, limiting the reliability of individual assessments. Therefore, we aimed to develop a deep learning model capable of distinguishing active from healed mucosa and differentiating between different endoscopic disease severity degrees. METHODS: One thousand four hundred eighty-four unique endoscopic images from 467 patients were extracted for classification. Two experts classified all images independently of one another according to the Mayo endoscopic subscore (MES). In cases of disagreement, a third expert classified the images. Different convolutional neural networks were considered for automatically classifying UC severity. Five-fold cross-validation was used to develop and select the final model. Afterward, unseen test data sets were used for model evaluation. RESULTS: In the most challenging task-distinguishing between all categories of MES-our final model achieved a test accuracy of 0.84. When evaluating this model on the binary tasks of distinguishing MES 0 vs 1-3 and 0-1 vs 2-3, it achieved accuracies of 0.94 and 0.93 and areas under the receiver operating characteristic curves of 0.997 and 0.998, respectively. DISCUSSION: We have developed a highly accurate, new, automated way of evaluating endoscopic images from patients with UC. We have demonstrated how our deep learning model is capable of distinguishing between all 4 MES levels of activity. This new automated approach may optimize and standardize the evaluation of disease severity measured by the MES across centers no matter the level of medical expertise.

来源:Am J Gastroenterol,查看原文。版权归原作者所有。

引用

  1. Lo B, Liu Z, Bendtsen F, et al. High Accuracy in Classifying Endoscopic Severity in Ulcerative Colitis Using Convolutional Neural Network. Am J Gastroenterol. 2022. PMID: 35849628. doi:10.14309/ajg.0000000000001904

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。