该前瞻性多中心国际研究在159例溃疡性结肠炎患者中评估PICaSSO评分在NBI和BLI/LCI平台上的可重复性,并与MES和UCEIS比较。PICaSSO合并队列的ICC为0.825,高于MES和UCEIS;在NBI队列中PICaSSO与RHI和NHI的相关性分别为0.83和0.79。结论认为PICaSSO评分可在NBI和LCI/BLI平台上一致且准确地重现。

要点

  • PICaSSO合并NBI和BLI/LCI队列的ICC为0.825,高于MES和UCEIS。
  • NBI队列中PICaSSO与RHI和NHI相关性分别为0.83和0.79,LCI/BLI队列为0.63和0.65。
  • PICaSSO评分可在NBI和LCI/BLI平台上一致且准确地重现。

核心结论

  • PICaSSO评分可在NBI和LCI/BLI平台上一致且准确地重现,因此可应用于所有虚拟电子染色内镜平台。

研究设计与样本

  • 前瞻性多中心国际研究,纳入159例溃疡性结肠炎患者(NBI队列78例,BLI/LCI队列81例),在2个三级转诊中心接受结肠镜检查。

主要发现

  • PICaSSO合并NBI和BLI/LCI队列的ICC为0.825,高于MES和UCEIS。
  • NBI队列中PICaSSO与RHI和NHI的相关性分别为0.83和0.79。
  • LCI/BLI队列中PICaSSO与RHI和NHI的相关性分别为0.63和0.65。
  • NBI队列中MES、UCEIS和PICaSSO预测RHI定义的组织学缓解的准确率分别为0.936、0.897和0.808。
  • NBI队列中MES、UCEIS和PICaSSO预测NHI定义的组织学缓解的准确率分别为0.897、0.885和0.821。

关键数值与推荐

  • 组织学缓解由Robarts组织病理学指数(RHI)和Nancy组织学指数(NHI)定义。
  • 使用受试者工作特征曲线评估内镜评分对组织学缓解的预测价值。
  • 评估内镜医师间的组内相关系数(ICC)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Endoscopic and histologic remission (HR) are key therapeutic targets in the management of ulcerative colitis (UC). The aim of this study was to evaluate the reproducibility of the Paddington International virtual ChromoendoScopy ScOre (PICaSSO), a virtual chromoendoscopy score originally validated by use of the iSCAN platform, with the narrow-band imaging (NBI), linked-color imaging (LCI), and blue-laser imaging (BLI) platforms. METHODS: We evaluated endoscopic activity using the Mayo Endoscopic Score (MES), the Ulcerative Colitis Endoscopic Index of Severity (UCEIS), and PICaSSO in 159 UC patients (78 NBI and 81 BLI/LCI) who underwent colonoscopy in 2 tertiary referral centers. HR was defined by the Robarts Histopathology Index (RHI) and the Nancy Histologic Index (NHI). Receiver operating characteristic curves were plotted to evaluate endoscopic scores for the prediction of HR. Intraclass correlation coefficients (ICC) between endoscopists were evaluated. RESULTS: PICaSSO had an ICC of 0.825 when the NBI and BLI/LCI cohorts were combined, higher than MES and UCEIS. The correlation between PICaSSO and RHI and NHI was 0.83 and 0.79 in the NBI cohort and between 0.63 and 0.65 in LCI/BLI. In the NBI cohort, the accuracy of MES, UCEIS, and PICaSSO was 0.936, 0.897, and 0.808 for HR measured by RHI and 0.897, 0.885, and 0.821 by NHI, respectively. In the BLI/LCI cohort, the accuracy of MES, UCEIS, LCI PICaSSO and BLI PICaSSO was 0.765, 0.778, 0.827, and 0.79 to predict HR with RHI and NHI, respectively. CONCLUSIONS: The PICaSSO score can be consistently and accurately reproduced with NBI and LCI/BLI and therefore can be applied to all virtual electronic chromoendoscopy platforms.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Cannatelli R, Bazarova A, Furfaro F, et al. Reproducibility of the electronic chromoendoscopy PICaSSO score (Paddington International Virtual ChromoendoScopy ScOre) in ulcerative colitis using multiple endoscopic platforms: a prospective multicenter international study (with video). Gastrointest Endosc. 2022. PMID: 35182574. doi:10.1016/j.gie.2022.02.012