磁共振小肠造影指数评估克罗恩病管腔病变活动度的反应性研究
本研究对41例克罗恩病患者治疗前后配对磁共振小肠造影图像由3名盲法放射科医生评分,评估4种磁共振小肠造影指数(MaRIA、简化MaRIA、London指数、London扩展指数)及100毫米视觉模拟量表(VAS)的反应性。以VAS改善至少半个标准差为变化标准,采用标准化效应量(SES)评价反应性。结果显示简化MaRIA的SES为1.17(95%CI 0.56-1.77),显著高于London指数(ΔSES 0.32,95%CI 0.05-0.58),但与MaRIA(ΔSES 0.18,95%CI -0.01至0.38)和London扩展指数(ΔSES 0.22,95%CI -0.05至0.50)无显著差异。结论认为这些指数具有中至大反应性,适用于临床试验,简化MaRIA可能因反应性及不依赖钆剂而更受青睐。
要点
- 简化MaRIA的SES为1.17(95%CI 0.56-1.77),在4种指数中最高。
- 简化MaRIA反应性显著优于London指数(ΔSES 0.32,95%CI 0.05-0.58)。
- 各指数与内镜和VAS的纵向相关性无显著差异。
核心结论
- 所评估的磁共振小肠造影指数显示中至大反应性,适用于临床试验。
- 简化MaRIA可能因反应性和不依赖钆剂给药而更受青睐。
研究设计与样本
- 配对磁共振小肠造影图像(治疗前及治疗第12或14周后)来自41例患者,由3名盲法放射科医生评分。
- 对4种磁共振小肠造影指数(MaRIA、简化MaRIA、London指数、London扩展指数)及100毫米VAS总体疾病活动度进行评分。
- 变化标准为治疗后VAS改善至少半个标准差,采用标准化效应量(SES)评估反应性。
主要发现
- SES:简化MaRIA为1.17(95%CI 0.56-1.77),MaRIA为0.98(95%CI 0.42-1.55),London扩展指数为0.95(95%CI 0.38-1.51),London指数为0.85(95%CI 0.31-1.39)。
- 简化MaRIA反应性显著高于London指数(ΔSES 0.32,95%CI 0.05-0.58)。
- 简化MaRIA与MaRIA的ΔSES为0.18(95%CI -0.01至0.38),与London扩展指数的ΔSES为0.22(95%CI -0.05至0.50),均未达统计学显著。
- 与内镜的相关性(简化MaRIA:r=0.72)与VAS的相关性(London扩展指数:r=0.70)无差异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND & AIMS: Magnetic resonance enterography (MRE) is having an increasing role in Crohn's disease; however, fully validated indices are needed. We evaluated the responsiveness of 4 MRE indices in luminal Crohn's disease. METHODS: Paired MRE images (pretreatment and post-treatment at weeks 12 or 14) from 41 patients were scored by 3 blinded radiologists. Disease activity was scored for 4 MRE indices (magnetic resonance index of activity [MaRIA], simplified MaRIA, London index, and London extended index) and a 100-mm visual analog scale (VAS) of overall disease activity. The criterion for change was an improvement by at least one half of an SD in the VAS after treatment. Responsiveness was evaluated using the standardized effect size (SES). Longitudinal validity was evaluated using correlations between changes in MRE index scores and disease activity measures including endoscopy and the VAS. RESULTS: The SES was 1.17 (95% CI, 0.56-1.77) for the simplified MaRIA, 0.98 (95% CI, 0.42-1.55) for the MaRIA, 0.95 (95% CI, 0.38-1.51) for the London extended index, and 0.85 (95% CI, 0.31-1.39) for the London index. The simplified MaRIA was significantly more responsive than the London index (ΔSES, 0.32; 95% CI, 0.05-0.58) but not the MaRIA (ΔSES, 0.18; 95% CI, -0.01 to 0.38) or the London extended index (ΔSES, 0.22; 95% CI, -0.05 to 0.50). Correlations with endoscopy (simplified MaRIA: r = 0.72) were not different from correlations with the VAS (London extended index: r = 0.70). CONCLUSIONS: Evaluated MRE indices showed moderate-to-large responsiveness and are suitable for use in clinical trials. The simplified MaRIA may be preferred because of its responsiveness and nonreliance on gadolinium administration.
引用
- Hanžel J, Jairath V, Ma C, et al. Responsiveness of Magnetic Resonance Enterography Indices for Evaluation of Luminal Disease Activity in Crohn's Disease. Clin Gastroenterol Hepatol. 2022. PMID: 35149220. doi:10.1016/j.cgh.2022.01.055
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。