文献速递消化内镜消化道肿瘤与早癌

冷圈套分块内镜黏膜切除术治疗大于1厘米的非壶腹部小肠腺瘤的结局:一项回顾性研究

Outcomes of cold snare piecemeal EMR for nonampullary small-bowel adenomas larger than 1 cm: a retrospective study.
PubMed 文献 · Gastrointest Endosc · 2021-12-29

这项回顾性研究在三级医疗中心纳入2014年1月至2019年3月接受抬举后分块冷圈套内镜黏膜切除术的小肠腺瘤≥1厘米患者,43例中39例有随访内镜。腺瘤残留或复发见于18例(46%),息肉大小与复发增高相关(P < .001);35例(89%)实现息肉根除,中位需2次(范围1-6)内镜操作;仅1例(2.3%)发生术后即时出血。作者认为分块冷圈套内镜黏膜切除术对于>10毫米的小肠息肉可能是可行、安全且有效的技术,并需前瞻性随机研究比较其与传统电灼切除的结局。

要点

  • 腺瘤残留或复发见于18例(46%),息肉大小与复发增高相关(P < .001)。
  • 息肉根除见于35例(89%),中位需2次(范围1-6)内镜操作。
  • 仅1例(2.3%)发生术后即时出血,未见穿孔或息肉切除后综合征。

核心结论

  • 分块冷圈套内镜黏膜切除术对于>10毫米的小肠息肉可能是可行、安全且有效的技术。
  • 需要前瞻性随机研究评估其结局与传统电灼切除的比较。

研究设计与样本

  • 回顾性研究,在三级医疗中心纳入2014年1月至2019年3月接受抬举后分块冷圈套内镜黏膜切除术的小肠腺瘤≥1厘米患者。
  • 43例接受分块冷圈套内镜黏膜切除术,其中39例有随访内镜。
  • 收集基线及监测内镜时的息肉特征,评估残留或复发腺瘤、息肉根除率及根除所需内镜操作次数,并评估即时和迟发出血、穿孔、狭窄、胰腺炎及息肉切除后综合征等不良事件。

主要发现

  • 息肉大小为10至70毫米(均值26.5毫米)。
  • 腺瘤残留或复发见于18例(46%),息肉大小与复发增高相关(P < .001)。
  • 息肉根除见于35例(89%),中位需2次(范围1-6)内镜操作。
  • 仅1例(2.3%)发生术后即时出血,未见穿孔或息肉切除后综合征病例。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND AIMS: Nonampullary small-bowel adenomas ≥10 mm are typically resected using cautery-based polypectomy, which is associated with significant adverse events. Studies have demonstrated the safety and efficacy of piecemeal cold snare EMR for removing large colon polyps. Our aim was to assess the safety and efficacy of cold snare EMR for removal of large adenomas in the small bowel. METHODS: A retrospective study of patients who underwent lift and piecemeal cold snare EMR of small-bowel adenomas ≥1 cm between January 2014 and March 2019 was conducted at a tertiary care medical center. Polyp characteristics at the time of index and surveillance endoscopy were collected. Primary outcomes were residual or recurrent adenoma (RRA) seen on surveillance endoscopy, polyp eradication rate, and number of endoscopic procedures required for eradication. Adverse events including immediate and delayed bleeding, perforation, stricture, pancreatitis, and postpolypectomy syndrome were assessed. RESULTS: Of 43 patients who underwent piecemeal cold snare EMR, 39 had follow-up endoscopy. Polyps ranged in size from 10 to 70 mm (mean, 26.5 mm). RRA was found in 18 patients (46%), with increased polyp size correlating with higher recurrence (P < .001). Polyp eradication was observed in 35 patients (89%), requiring a median of 2 (range, 1-6) endoscopic procedures. Only 1 patient (2.3%) had immediate postprocedural bleeding. No cases of perforation or postpolypectomy syndrome were seen. CONCLUSIONS: Piecemeal cold snare EMR may be a feasible, safe, and efficacious technique for small-bowel polyps >10 mm. Prospective, randomized studies are needed to assess how outcomes compare with traditional cautery-based polypectomy.

来源:Gastrointest Endosc,查看原文。版权归原作者所有。

引用

  1. Dang DT, Suresh S, Vance RB, et al. Outcomes of cold snare piecemeal EMR for nonampullary small-bowel adenomas larger than 1 cm: a retrospective study. Gastrointest Endosc. 2021. PMID: 34971667. doi:10.1016/j.gie.2021.12.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。