Endocuff联合人工智能辅助结肠镜检测结直肠腺瘤的随机试验
这项三臂随机对照试验纳入682例40岁以上患者,比较Endocuff联合AI、单用AI与标准高清结肠镜的腺瘤检出率。结果显示Endocuff联合AI组的腺瘤检出率显著高于单用AI组(58.7%对53.8%,差值4.9%,95%CI 1.4%-8.2%,P=0.03),且联合组与AI组均优于标准高清结肠镜。
要点
- Endocuff联合AI较单用AI显著提高腺瘤检出率(差值4.9%,P=0.03)。
- 联合组息肉检出率和无蒂锯齿状病变检出率也显著高于单用AI组。
- 联合组与AI组的腺瘤、息肉、无蒂锯齿状病变及进展期腺瘤检出率均高于标准高清结肠镜。
核心结论
- 与单用AI相比,Endocuff联合AI可进一步提高结肠镜检查中多种结肠病变的检出率。
研究设计与样本
- 三臂前瞻性随机结肠镜研究,纳入682例40岁及以上患者,按1:1:1随机分配至Endocuff联合AI组、单用AI组或标准高清结肠镜组。
主要发现
- Endocuff联合AI组、单用AI组和标准高清组的腺瘤检出率分别为58.7%、53.8%和46.3%。
- Endocuff联合AI组与单用AI组的腺瘤检出率差值为4.9%(95%CI 1.4%-8.2%,P=0.03)。
- Endocuff联合AI组与单用AI组的息肉检出率差值为3.0%(95%CI 0.4%-5.8%,P=0.04)。
- Endocuff联合AI组与单用AI组的无蒂锯齿状病变检出率差值为6.4%(95%CI 3.4%-9.7%,P<0.01)。
- Endocuff联合AI组和单用AI组的腺瘤、息肉、无蒂锯齿状病变及进展期腺瘤检出率均高于标准高清组(均P<0.01)。
关键数值与推荐
- 腺瘤检出率:Endocuff联合AI组58.7%,单用AI组53.8%,标准高清组46.3%。
- 息肉检出率:Endocuff联合AI组77.0%,单用AI组74.0%,标准高清组61.2%。
临床怎么用
- 在AI辅助结肠镜基础上加用Endocuff可能进一步提升腺瘤及无蒂锯齿状病变的检出。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Both artificial intelligence (AI) and distal attachment devices have been shown to improve adenoma detection rate and reduce miss rate during colonoscopy. We studied the combined effect of Endocuff and AI on enhancing detection rates of various colonic lesions. METHODS: This was a 3-arm prospective randomized colonoscopy study involving patients aged 40 years or older. Participants were randomly assigned in a 1:1:1 ratio to undergo Endocuff with AI, AI alone, or standard high-definition (HD) colonoscopy. The primary outcome was adenoma detection rate (ADR) between the Endocuff-AI and AI groups while secondary outcomes included detection rates of polyp (PDR), sessile serrated lesion (sessile detection rate [SDR]), and advanced adenoma (advanced adenoma detection rate) between the 2 groups. RESULTS: A total of 682 patients were included (mean age 65.4 years, 52.3% male), with 53.7% undergoing diagnostic colonoscopy. The ADR for the Endocuff-AI, AI, and HD groups was 58.7%, 53.8%, and 46.3%, respectively, while the corresponding PDR was 77.0%, 74.0%, and 61.2%. A significant increase in ADR, PDR, and SDR was observed between the Endocuff-AI and AI groups (ADR difference: 4.9%, 95% CI: 1.4%-8.2%, P = 0.03; PDR difference: 3.0%, 95% CI: 0.4%-5.8%, P = 0.04; SDR difference: 6.4%, 95% CI: 3.4%-9.7%, P < 0.01). Both Endocuff-AI and AI groups had a higher ADR, PDR, SDR, and advanced adenoma detection rate than the HD group (all P < 0.01). DISCUSSION: Endocuff in combination with AI further improves various colonic lesion detection rates when compared with AI alone.
引用
- Lui TK, Lam CP, To EW, et al. Endocuff With or Without Artificial Intelligence-Assisted Colonoscopy in Detection of Colorectal Adenoma: A Randomized Colonoscopy Trial. Am J Gastroenterol. 2024. PMID: 38305278. doi:10.14309/ajg.0000000000002684
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。