可穿戴传感器环境智能老年管理系统预防老年住院患者跌倒的效果
该研究为3个病房的阶梯整群随机对照试验,纳入3240例≥65岁住院患者,评估AmbIGeM可穿戴传感器系统对跌倒率的影响。结果显示干预组与对照组在跌倒率、跌倒伤害率及跌倒患者比例上均无显著差异,但事后分析提示老年评估与管理病房干预期跌倒率降低。
要点
- AmbIGeM系统未显著降低老年住院患者跌倒率、伤害性跌倒率或跌倒患者比例。
- 事后分析提示老年评估与管理病房干预期跌倒和伤害性跌倒率降低,需进一步验证。
- 患者有效读数时间中位比例仅49%,可能影响系统效果评估。
核心结论
- AmbIGeM可穿戴传感器系统未能减少老年住院患者的跌倒率、伤害性跌倒率或跌倒患者比例。
研究设计与样本
- 3个病房(跨2个州)的阶梯整群实用性试验,纳入≥65岁住院患者,排除需安宁疗护者,共3240例入组(对照组1995例,干预组1245例)。
主要发现
- 患者有效读数时间中位比例为49%(IQR 25%-67%)。
- 事后分析中,老年评估与管理病房干预期与对照期相比,跌倒和伤害性跌倒率降低。
临床怎么用
- 当前证据不支持常规部署AmbIGeM系统以降低老年住院患者跌倒,需进一步优化技术并在特定病房(如老年评估与管理病房)中验证。
局限性
- 患者有效读数时间中位比例仅49%,可能低估系统效果。
- 事后分析结果需前瞻性研究确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The Ambient Intelligent Geriatric Management (AmbIGeM) system augments best practice and involves a novel wearable sensor (accelerometer and gyroscope) worn by patients where the data captured by the sensor are interpreted by algorithms to trigger alerts on clinician handheld mobile devices when risk movements are detected. METHODS: A 3-cluster stepped-wedge pragmatic trial investigating the effect on the primary outcome of falls rate and secondary outcome of injurious fall and proportion of fallers. Three wards across 2 states were included. Patients aged ≥65 years were eligible. Patients requiring palliative care were excluded. The trial was registered with the Australia and New Zealand Clinical Trials registry, number 12617000981325. RESULTS: A total of 4924 older patients were admitted to the study wards with 1076 excluded and 3240 (1995 control, 1245 intervention) enrolled. The median proportion of study duration with valid readings per patient was 49% ((interquartile range [IQR] 25%-67%)). There was no significant difference between intervention and control relating to the falls rate (adjusted rate ratio = 1.41, 95% confidence interval [0.85, 2.34]; p = .192), proportion of fallers (odds ratio = 1.54, 95% confidence interval [0.91, 2.61]; p = .105), and injurious falls rate (adjusted rate ratio = 0.90, 95% confidence interval [0.38, 2.14]; p = .807). In a post hoc analysis, falls and injurious falls rate were reduced in the Geriatric Evaluation and Management Unit wards when the intervention period was compared to the control period. CONCLUSIONS: The AmbIGeM system did not reduce the rate of falls, rate of injurious falls, or proportion of fallers. There remains a case for further exploration and refinement of this technology given the post hoc analysis findings with the Geriatric Evaluation and Management Unit wards. Clinical Trials Registration Number: 12617000981325.
引用
- Visvanathan R, Ranasinghe DC, Lange K, et al. Effectiveness of the Wearable Sensor-based Ambient Intelligent Geriatric Management (AmbIGeM) System in Preventing Falls in Older People in Hospitals. J Gerontol A Biol Sci Med Sci. 2022. PMID: 34153102. doi:10.1093/gerona/glab174
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。