该研究为6个月非随机对照试验,纳入134名佩戴Tango Belt的干预组和264名倾向匹配历史对照,对象为≥65岁高跌倒损伤风险养老机构居民。结果显示干预组严重髋部撞击跌倒所致主要髋部损伤、髋部骨折、急诊就诊和住院均显著少于对照组,总体跌倒率无显著差异。提示可穿戴跌倒损伤防护技术可作为现有跌倒预防策略的有效补充。
要点
- 可穿戴安全气囊腰带显著减少高风险老年人严重髋部撞击跌倒所致主要髋部损伤。
- 干预组跌倒相关髋部骨折、急诊就诊和住院均显著低于对照组。
- 两组总体跌倒率无显著差异,装置依从性为67%可佩戴日。
核心结论
- 可穿戴安全气囊腰带显著减少高风险老年人的跌倒相关髋部损伤及医疗资源利用。
研究设计与样本
- 6个月非随机对照试验,采用倾向匹配历史对照和盲法结局评估(NCT05245097)。
- 研究在美国11家养老机构开展,纳入134名佩戴Tango Belt的干预参与者和264名匹配历史对照。
- 参与者年龄≥65岁,能在独立至大量协助下转移/行走,基于跌倒骨折史或跌倒史伴骨量丢失判定为高跌倒损伤风险。
主要发现
- 干预组严重髋部撞击跌倒所致主要髋部损伤为1.1% vs 12.1%(RR 0.091;95%CI 0.0-3.9;P<.004)。
- 干预组跌倒相关髋部骨折为2.2% vs 11.4%(RR 0.19;95%CI 0.5-6.4;P=.003)。
- 干预组急诊就诊为6.0% vs 17.8%(RR 0.34;95%CI 2.6-11.4;P≤.001),住院为8.2% vs 18.9%(RR 0.43;95%CI 4.2-14.2;P=.003)。
- 总体跌倒率两组无显著差异(每180天1.56 vs 1.31次跌倒;P=.075)。
- 意向治疗组总体依从性为67%可佩戴日,佩戴日中位设备使用时间为每日8.8小时;装置在6次严重髋部撞击跌倒中检测并展开,无相关髋部损伤。
关键数值与推荐
- 主要结局为6个月内严重髋部撞击跌倒所致主要髋部损伤,由对分组不知情的老年科医生裁定。
临床怎么用
- 对于高跌倒损伤风险的老年人,可考虑在标准跌倒预防基础上加用可穿戴安全气囊腰带。
- 该技术可能减少跌倒相关髋部骨折及急诊和住院风险,但总体跌倒率未必下降。
局限性
- 研究为非随机对照设计,采用历史对照和倾向匹配,可能存在残余混杂。
- 干预组样本量134例,对照组264例,研究期限为6个月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the effectiveness of a wearable airbag belt in preventing fall-related hip injuries among older adults at high risk for injurious falls in older adult care settings. DESIGN: Six-month, nonrandomized controlled trial with propensity-matched historical controls and blinded outcome assessment (NCT05245097). SETTING AND PARTICIPANTS: Study conducted across 11 older adult residential facilities in the United States, including 134 intervention participants wearing the Tango Belt and 264 matched historical controls. Participants were aged ≥65 years, able to transfer/ambulate with assistance ranging from independent to extensive assistance, and at high risk for fall injuries based on fall fracture history or fall history with bone loss. METHODS: Intervention participants wore the Tango Belt, a device using motion sensors to detect serious hip-impacting falls and deploy airbag protection, in addition to standard of care (SOC) for fall prevention. Controls received SOC alone. The primary outcome was major hip injuries due to serious hip-impacting falls over 6 months, adjudicated by a geriatrician blinded to group assignment. Secondary outcomes included fall-related hip fractures, emergency department visits, and hospitalizations. RESULTS: The intervention group experienced significantly fewer major hip injuries from serious hip-impacting falls [1.1% vs 12.1%, relative risk (RR), 0.091; 95% CI, 0.0-3.9; P < .004], fall-related hip fractures (2.2% vs 11.4%, RR, 0.19; 95% CI 0.5-6.4; P = .003), emergency department visits (6.0% vs 17.8%, RR, 0.34; 95% CI, 2.6-11.4; P ≤ .001), and hospitalizations (8.2% vs 18.9%, RR, 0.43; 95% CI, 4.2-14.2; P = .003) compared with controls. Overall fall rates did not differ significantly between intervention and control groups (1.56 vs 1.31 falls per 180 days, respectively; P = .075). Overall adherence in the intention-to-treat group was 67% of possible wear days with a median device wear time of 8.8 hours daily on days worn. The device detected and deployed during 6 serious hip-impacting falls with no associated hip injuries. CONCLUSIONS AND IMPLICATIONS: The wearable airbag belt significantly reduced fall-related hip injuries and associated health care utilization in high-risk older adults. These results suggest that wearable fall injury protection technology may provide an effective complement to existing fall prevention strategies in the older adult population.
引用
- Stefanacci RG, Kinosian B. Mitigating Hip Injuries in High-Risk Older Adults: Clinical Evidence Supporting FDA Approval of a Novel Wearable Airbag Belt. J Am Med Dir Assoc. 2025. PMID: 40887039. doi:10.1016/j.jamda.2025.105851