超声影像组学联合机器学习提升养老院居民肌少症检测准确性
本研究为诊断准确性研究,纳入中国15家养老院628名居民,以AWGS 2019标准诊断肌少症,比较传统超声参数、影像组学及整合模型(含年龄、性别、BMI)的诊断效能。逻辑回归算法表现最优,整合模型在验证集中对股直肌、股中间肌、股四头肌的AUC分别为0.85、0.81、0.83,优于传统超声模型和影像组学模型。结论认为超声影像组学整合临床数据可显著提高养老院居民肌少症诊断准确性。
要点
- 逻辑回归算法在肌少症诊断中表现最优。
- 整合模型AUC达0.81–0.85,优于传统超声模型(0.70–0.75)。
- 影像组学模型AUC为0.76–0.78,亦优于传统超声参数。
核心结论
- 超声影像组学,尤其联合传统参数与临床数据并使用逻辑回归时,可显著提高养老院居民肌少症诊断准确性。
研究设计与样本
- 诊断准确性研究,纳入中国15家养老院628名居民,按70%/30%分为训练集与验证集。
主要发现
- 肌少症患病率为61.9%,逻辑回归算法在各模型中表现最优。
- 验证集中传统超声模型AUC(95%CI)为:股直肌0.70(0.63–0.78)、股中间肌0.73(0.65–0.80)、股四头肌0.75(0.68–0.82)。
- 验证集中影像组学模型AUC(95%CI)为:股直肌0.76(0.69–0.83)、股中间肌0.76(0.69–0.83)、股四头肌0.78(0.71–0.85)。
- 整合模型AUC(95%CI)为:股直肌0.85(0.79–0.91)、股中间肌0.81(0.75–0.87)、股四头肌0.83(0.77–0.90),校准良好且决策曲线分析显示净获益。
关键数值与推荐
- 肌少症诊断采用AWGS 2019标准。
- 超声测量大腿肌肉包括股直肌、股中间肌和股四头肌,提取肌肉厚度、回声强度及影像组学特征。
- 整合模型纳入肌肉厚度、回声强度、影像组学特征及年龄、性别、体重指数等基本临床数据。
临床怎么用
- 在长期照护机构中,可考虑采用超声影像组学整合模型辅助肌少症筛查与早期检测。
- 该方法无创且可及,但需进一步外部验证后方可推广至常规临床。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Ultrasound only has low-to-moderate accuracy for sarcopenia. We aimed to investigate whether ultrasound radiomics combined with machine learning enhances sarcopenia diagnostic accuracy compared with conventional ultrasound parameters among older adults in long-term care. DESIGN: Diagnostic accuracy study. SETTING AND PARTICIPANTS: A total of 628 residents from 15 nursing homes in China. METHODS: Sarcopenia diagnosis followed AWGS 2019 criteria. Ultrasound of thigh muscles [rectus femoris (ReF), vastus intermedius (VI), and quadriceps femoris (QF)] was performed. Conventional parameters [muscle thickness (MT), echo intensity (EI)] and radiomic features were extracted. Participants were split into training (70%)/validation (30%) sets. Conventional (muscle thickness + EI), radiomics, and integrated (MT, echo intensity, radiomics, basic clinical data including age, sex, and body mass index) models were built using 5 machine learning algorithms [including logistic regression (LR)]. Performance was assessed in the validation set using the area under the receiver operating characteristic curve (AUC), calibration, and decision curve analysis (DCA). RESULTS: Sarcopenia prevalence was 61.9%. The LR algorithm consistently exhibited superior performance. The diagnostic accuracy of the ultrasound radiomic models was superior to that of the models based on conventional ultrasound parameters, regardless of muscle group. The integrated models further improved the accuracy, achieving AUCs (95% CIs) of 0.85 (0.79-0.91) for ReF, 0.81 (0.75-0.87) for VI, and 0.83 (0.77-0.90) for QF. In the validation set, the AUCs (95% CIs) for the conventional ultrasound models were 0.70 (0.63-0.78) for ReF, 0.73 (0.65-0.80) for VI, and 0.75 (0.68-0.82) for QF. The corresponding AUCs (95% CIs) for the radiomics models were 0.76 (0.69-0.83) for ReF, 0.76 (0.69-0.83) for VI, and 0.78 (0.71-0.85) for QF. The integrated models demonstrated good calibration and net benefit in DCA. CONCLUSIONS AND IMPLICATIONS: Ultrasound radiomics, especially when integrated with conventional parameters and clinical data using LR, significantly improves sarcopenia diagnostic accuracy in nursing home residents. This accessible, noninvasive approach holds promise for enhancing sarcopenia screening and early detection in long-term care settings.
引用
- Fu H, Luo S, Zhuo Y, et al. Enhanced Sarcopenia Detection in Nursing Home Residents Using Ultrasound Radiomics and Machine Learning. J Am Med Dir Assoc. 2025. PMID: 40882952. doi:10.1016/j.jamda.2025.105830
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。