文献速递衰弱、肌少症与跌倒老年综合评估

3米倒退行走测试预测老年人跌倒风险的准确性

Predictive Accuracy of the 3-m Backward Walk Test for Fall Risk in Older Adults.
PubMed 文献 · J Am Med Dir Assoc · 2025-07-26

本研究在维也纳两家养老院纳入217名老年人,评估3米倒退行走测试(3 MBWT)预测跌倒风险的准确性,并与SPPB、10米步行测试和跌倒相关问卷比较。结果显示3 MBWT与SPPB预测准确性相近,对前瞻性跌倒的预测优于10米步行测试,且更省时高效。

要点

  • 3 MBWT预测回顾性跌倒的AUC为0.75,与SPPB(0.76)和10米步行测试(0.73)相近。
  • 3 MBWT预测前瞻性跌倒的AUC为0.74,与SPPB(0.75)相近,优于10米步行测试(0.67)。
  • 3 MBWT≥9.31秒与回顾性跌倒发生率升高32%相关,≥8.15秒与前瞻性跌倒发生率升高27%相关。

核心结论

  • 3 MBWT预测跌倒风险的准确性与SPPB相当,对前瞻性跌倒的预测略优于10米步行测试,且省时高效,适合临床使用。

研究设计与样本

  • 横断面研究,在奥地利维也纳2家养老院纳入217名参与者(女性65.9%,中位年龄80岁)。
  • 通过访谈和Cogvis 3D传感器系统回顾性记录12个月跌倒史,并前瞻性记录4个月跌倒情况。

主要发现

  • 217名参与者中86人(39.6%)报告过去12个月内发生过跌倒。
  • 回顾性跌倒:SPPB的AUC为0.76,3 MBWT为0.75,10米步行测试为0.73。
  • 前瞻性跌倒:SPPB的AUC为0.75,3 MBWT为0.74,10米步行测试为0.67。
  • 3 MBWT每增加1秒,回顾性跌倒发生率增加7%,前瞻性跌倒发生率增加5%。

关键数值与推荐

  • 3 MBWT预测回顾性跌倒的切点为≥9.31秒,对应跌倒发生率升高32%(95%CI,1.05-1.95)。
  • 3 MBWT预测前瞻性跌倒的切点为≥8.15秒,对应跌倒发生率升高27%(95%CI,1.02-1.66)。
  • SPPB切点<7.02与跌倒发生率升高49%相关(95%CI,1.06-2.21),<8.00与升高30%相关(95%CI,1.02-1.74)。

临床怎么用

  • 3 MBWT可作为老年人跌倒风险评估的实用工具,尤其适合需要快速筛查的临床场景。
  • 可参考3 MBWT切点(回顾性≥9.31秒、前瞻性≥8.15秒)识别高跌倒风险老年人。

局限性

  • 研究为横断面设计,样本来自维也纳2家养老院,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Falls are a leading cause of injury in older adults, and accurate tools to predict fall risk are essential. This study evaluates the predictive accuracy of the 3-m Backward Walk Test (3 MBWT) for fall risk, comparing it with the Short Physical Performance Battery (SPPB), 10-m walk test (10 MWT), and fall-related questionnaires. DESIGN: Cross-sectional study. SETTING AND PARTICIPANTS: The study was conducted in 2 nursing homes in Vienna, Austria. A total of 217 participants (65.9% female, median age, 80 years) were included. METHODS: Fall history was recorded retrospectively over 12 months and prospectively over 4 months using interviews and a Cogvis 3D sensor system. Predictive accuracy was assessed with receiver operating characteristic curves and area under the curve (AUC) analyses, whereas Poisson regression was used to analyze fall incidence. RESULTS: Among participants, 86 (39.6%) reported a fall within the previous 12 months. For retrospective falls, the SPPB (AUC, 0.76), 3 MBWT (AUC, 0.75), and 10 MWT (AUC, 0.73) showed similar predictive accuracy. For prospective falls, the SPPB (AUC, 0.75) and 3 MBWT (AUC, 0.74) remained similarly accurate, whereas the 10 MWT had lower predictive power (AUC, 0.67). For the 3 MBWT, cutoff points were ≥9.31 seconds for retrospective falls (32% higher incidence; 95% CI, 1.05-1.95) and ≥8.15 seconds for prospective falls (27% higher incidence; 95% CI, 1.02-1.66). Each additional second in 3 MBWT performance increased fall incidence (retrospective, 7%; prospective, 5%). SPPB cutoffs of <7.02 and <8.00 were associated with 49% (95% CI, 1.06-2.21) and 30% (95% CI, 1.02-1.74) higher fall incidence, respectively. CONCLUSIONS AND IMPLICATIONS: The 3 MBWT shows comparable accuracy with the SPPB and moderately better performance than the 10 MWT for prospective falls. Its efficiency, predictive value, and time savings make it a practical and viable tool for clinical fall risk assessment in older adults.

来源:J Am Med Dir Assoc,查看原文。版权归原作者所有。

引用

  1. Kapan A, Ristic M, Felsinger R, et al. Predictive Accuracy of the 3-m Backward Walk Test for Fall Risk in Older Adults. J Am Med Dir Assoc. 2025. PMID: 40187370. doi:10.1016/j.jamda.2025.105580

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。