相位角筛查肌少症的诊断准确性及截断值:系统综述与Meta分析
该Meta分析纳入18项研究共6184名参与者,评估相位角(PhA)筛查肌少症的诊断准确性。汇总AUC为0.81,灵敏度80%、特异度70%,推荐的截断值95%CI为4.54°至5.25°。种族、BMI、健康状况和诊断标准是影响诊断准确性的主要因素。
要点
- PhA筛查肌少症的汇总AUC为0.81,灵敏度80%、特异度70%。
- 推荐的PhA截断值95%CI为4.54°至5.25°。
- 种族、BMI、健康状况和诊断标准影响PhA筛查准确性。
核心结论
- PhA可能作为肌少症的有效筛查工具,推荐截断值区间为4.54°至5.25°。
研究设计与样本
- 系统综述与Meta分析,检索PubMed、Embase和Cochrane Library至2023年9月18日,纳入18项研究共6184名参与者。
主要发现
- 汇总AUC值为0.81。
- 汇总灵敏度为80%,特异度为70%。
- Meta回归分析显示种族、BMI、健康状况和诊断标准是影响诊断准确性的主要因素(所有P值<0.01)。
关键数值与推荐
- PhA筛查肌少症的截断值95%CI为4.54°至5.25°。
临床怎么用
- 临床可参考PhA截断值区间4.54°至5.25°筛查肌少症,但需考虑种族、BMI、健康状况和诊断标准的影响。
局限性
- 种族、BMI、健康状况和诊断标准等因素导致异质性,可能影响PhA筛查的准确性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Phase angle (PhA) declines with age and is a reliable marker for muscle function, making it a potential screening indicator for sarcopenia. However, studies examined the reliability and validity of PhA for detecting sarcopenia, yielding inconsistent results. This meta-analysis aimed to evaluate the accuracy and cutoff value of PhA for screening sarcopenia and examine the potential confounding factors. DESIGN: This is a meta-analysis. SETTING AND PARTICIPANTS: PubMed, Embase, and Cochrane Library were searched up to September 18, 2023. Eighteen studies (6184 participants) were included reporting the diagnostic accuracy of PhA for screening sarcopenia. METHODS: Pooled accuracy [ie, the computed area under the curve value (AUC)] and cutoff value interval for screening sarcopenia were estimated using a random-effects model. Meta-regression analyses were conducted to identify sources of heterogeneity. RESULTS: The AUC value was 0.81. Pooled sensitivity and specificity were 80% and 70%. The calculated 95% CI of the cutoff value of PhA for screening sarcopenia falls between 4.54° and 5.25°. The results of meta-regression analyses showed that ethnicity, body mass index (BMI), health status, and diagnostic criteria were the main factors affecting the diagnostic accuracy for screening sarcopenia (with all P values < 0.01). CONCLUSION AND IMPLICATIONS: PhA may serve as a robust screening tool for sarcopenia, and the recommended cutoff interval falls between 4.54° and 5.25°. Ethnicity, BMI, health status, and diagnostic criteria can affect PhA's efficacy in sarcopenia screening.
引用
- Zhang J, Wang N, Li J, et al. The Diagnostic Accuracy and Cutoff Value of Phase Angle for Screening Sarcopenia: A Systematic Review and Meta-Analysis. J Am Med Dir Assoc. 2024. PMID: 39326856. doi:10.1016/j.jamda.2024.105283
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。