文献速递认知障碍与谵妄

综合医院常规实践中谵妄检测工具大规模应用时完成率和阳性评分率存在差异:一项系统综述

Delirium detection tools show varying completion rates and positive score rates when used at scale in routine practice in general hospital settings: A systematic review.
PubMed 文献 · J Am Geriatr Soc · 2024-01-19

该系统综述纳入22项研究和4份审计报告,评估综合医院大规模临床人群中谵妄检测工具的完成率和谵妄阳性评分率。工具包括CAM、4AT、DOSS、bCAM、NuDESC和ICDSC,完成率范围19%至100%,入院阳性率CAM为8%-51%、4AT为13%-20%,住院阳性率CAM为2%-20%、DOSS为6%-42%、NuDESC为5-13%,术后4AT阳性率为21%和28%。结论指出常规实践中工具完成率和阳性评分率存在临床重要变异。

要点

  • 谵妄检测工具在常规实践中的完成率变异大(19%-100%)。
  • 不同工具和场景的谵妄阳性评分率差异显著,需结合预期患病率解读。
  • 多数研究存在中高偏倚风险,需加强医疗系统数据的报告与分析。

核心结论

  • 在大规模急性患者人群中实施谵妄检测工具,工具完成率和谵妄阳性评分率相对预期患病率存在临床重要变异。

主要发现

  • 工具完成率范围为19%至100%。
  • 入院阳性评分率:CAM为8%-51%,4AT为13%-20%。
  • 住院阳性评分率:CAM为2%-20%,DOSS为6%-42%,NuDESC为5-13%。
  • 术后阳性评分率:4AT为21%和28%。
  • 除两项研究外,所有研究均存在中高偏倚风险。

关键数值与推荐

  • 纳入标准:使用经验证谵妄检测工具直接对患者进行常规 care 评估,人群n≥1000,综合急性医院 setting。
  • 使用的工具包括CAM、4AT、DOSS、bCAM、NuDESC和ICDSC,可单独或组合使用。

临床怎么用

  • 临床使用谵妄检测工具时需关注完成率和阳性评分率在真实世界中的变异,结合预期患病率解读结果。
  • 需加强医疗系统数据的报告和分析,以推进常规 care 中有效谵妄检测的理解。

局限性

  • 所有但两项研究存在中高偏倚风险。
  • 人群和 setting 多样,工具使用阶段和频率不同。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Multiple short delirium detection tools have been validated in research studies and implemented in routine care, but there has been little study of these tools in real-world conditions. This systematic review synthesized literature reporting completion rates and/or delirium positive score rates of detection tools in large clinical populations in general hospital settings. METHODS: PROSPERO (CRD42022385166). Medline, Embase, PsycINFO, CINAHL, and gray literature were searched from 1980 to December 31, 2022. Included studies or audit reports used a validated delirium detection tool performed directly with the patient as part of routine care in large clinical populations (n ≥ 1000) within a general acute hospital setting. Narrative synthesis was performed. RESULTS: Twenty-two research studies and four audit reports were included. Tools used alone or in combination were the Confusion Assessment Method (CAM), 4 'A's Test (4AT), Delirium Observation Screening Scale (DOSS), Brief CAM (bCAM), Nursing Delirium Screening Scale (NuDESC), and Intensive Care Delirium Screening Checklist (ICDSC). Populations and settings varied and tools were used at different stages and frequencies in the patient journey, including on admission only; inpatient, daily or more frequently; on admission and as inpatient; inpatient post-operatively. Tool completion rates ranged from 19% to 100%. Admission positive score rates ranged from: CAM 8%-51%; 4AT 13%-20%. Inpatient positive score rates ranged from: CAM 2%-20%, DOSS 6%-42%, and NuDESC 5-13%. Postoperative positive score rates were 21% and 28% (4AT). All but two studies had moderate-high risk of bias. CONCLUSIONS: This systematic review of delirium detection tool implementation in large acute patient populations found clinically important variability in tool completion rates, and in delirium positive score rates relative to expected delirium prevalence. This study highlights a need for greater reporting and analysis of relevant healthcare systems data. This is vital to advance understanding of effective delirium detection in routine care.

来源:J Am Geriatr Soc,查看原文。版权归原作者所有。

引用

  1. Penfold RS, Squires C, Angus A, et al. Delirium detection tools show varying completion rates and positive score rates when used at scale in routine practice in general hospital settings: A systematic review. J Am Geriatr Soc. 2024. PMID: 38241503. doi:10.1111/jgs.18751

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。