文献速递安宁疗护老年综合评估

识别养老院居民未满足安宁疗护需求的筛查工具测量特性系统综述

Identifying Nursing Home Residents with Unmet Palliative Care Needs: A Systematic Review of Screening Tool Measurement Properties.
PubMed 文献 · J Am Med Dir Assoc · 2023-04-06

该系统综述依据COSMIN指南,检索Embase、MEDLINE、CINAHL和PsycINFO至2022年5月,纳入开发或评估安宁疗护筛查工具且样本为养老院老年人的研究。仅识别出1个符合COSMIN标准的工具NEC-PAL,但其在养老院居民中使用的证据质量低,缺乏信度、灵敏度和特异度的稳健测试,仅1项研究报告了 adequate 的结构效度。因此证据不足以指导实践,建议未来验证现有工具并开发针对养老院的新工具。

要点

  • 仅NEC-PAL符合COSMIN标准,但养老院使用证据质量低。
  • NEC-PAL缺乏在养老院环境下的信度、灵敏度和特异度稳健测试。
  • 结构效度仅1项研究报告且为 adequate,证据不足以指导实践。

核心结论

  • 仅1个安宁疗护筛查工具NEC-PAL符合COSMIN标准,但养老院居民使用证据质量低。
  • 证据不足以指导实践,建议未来验证现有工具并开发针对养老院的新工具。

研究设计与样本

  • 系统综述,遵循COSMIN指南评估测量特性。
  • 检索Embase、MEDLINE、CINAHL和PsycINFO从建库至2022年5月。
  • 纳入报告安宁疗护筛查工具开发或评估且样本为养老院老年人的研究。
  • 两名评价者独立筛选、提取数据并评估偏倚风险。

主要发现

  • 仅识别出1个符合COSMIN标准的工具NEC-PAL(NECesidades Paliativas,即安宁疗护需求)。
  • NEC-PAL在养老院环境下缺乏信度、灵敏度和特异度的稳健测试。
  • 结构效度通过假设检验为 adequate,但仅1项研究报告。
  • 另报告3个在全文审查时因各种原因被排除的安宁疗护筛查工具。

关键数值与推荐

  • NEC-PAL的结构效度仅1项研究报告为 adequate。
  • NEC-PAL在养老院环境下的信度、灵敏度和特异度缺乏稳健测试。

临床怎么用

  • 建议临床医生考虑本综述呈现的证据,选择最符合其需求的筛查工具。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Despite common use of palliative care screening tools in other settings, the performance of these tools in the nursing home has not been well established; therefore, the purpose of this review is to (1) identify palliative care screening tools validated for nursing home residents and (2) critically appraise, compare, and summarize the quality of measurement properties. DESIGN: Systematic review of measurement properties consistent with Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) guidelines. SETTINGS AND PARTICIPANTS: Embase (Ovid), MEDLINE (PubMed), CINAHL (EBSCO), and PsycINFO (Ovid) were searched from inception to May 2022. Studies that (1) reported the development or evaluation of a palliative care screening tool and (2) sampled older adults living in a nursing home were included. METHODS: Two reviewers independently screened, selected, extracted data, and assessed risk of bias. RESULTS: We identified only 1 palliative care screening tool meeting COSMIN criteria, the NECesidades Paliativas (NEC-PAL, equivalent to palliative needs in English), but evidence for use with nursing home residents was of low quality. The NEC-PAL lacked robust testing of measurement properties such as reliability, sensitivity, and specificity in the nursing home setting. Construct validity through hypothesis testing was adequate but only reported in 1 study. Consequently, there is insufficient evidence to guide practice. Broadening the criteria further, this review reports on 3 additional palliative care screening tools identified during the search and screening process but which were excluded during full-text review for various reasons. CONCLUSION AND IMPLICATIONS: Given the unique care environment of nursing homes, we recommend future studies to validate available tools and develop new instruments specifically designed for nursing home use. In the meantime, we recommend that clinicians consider the evidence presented here and choose a screening instrument that best meets their needs.

来源:J Am Med Dir Assoc,查看原文。版权归原作者所有。

引用

  1. Cole CS, Roydhouse J, Fink RM, et al. Identifying Nursing Home Residents with Unmet Palliative Care Needs: A Systematic Review of Screening Tool Measurement Properties. J Am Med Dir Assoc. 2023. PMID: 37030323. doi:10.1016/j.jamda.2023.02.112

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。