本研究基于洛桑65+队列1887名72-77岁社区老年人,比较步行速度(WS)与Moberg拾取试验(MPUT)测量的慢速对功能衰退的预测能力。结果显示,两种慢速测量均与1年和4年随访时基本日常生活活动(BADL)能力下降正相关,且预测值无显著差异;除工具性日常生活活动(IADL)下降的预测WS略优外,次要结局的预测也无显著差异。结论提示MPUT或可作为慢速的替代测量指标,用于预测功能衰退。
要点
- MPUT与步行速度测量的慢速均与1年和4年BADL下降正相关。
- 除IADL下降WS预测略优外,次要结局预测无显著差异。
核心结论
- MPUT可能是预测功能衰退的慢速替代测量指标。
研究设计与样本
- 前瞻性纵向观察研究,使用基于人群的洛桑65+队列数据。
- 基线1887名72-77岁个体完成步行速度(20米常速)和MPUT(拾取12个物体)评估。
- 结局在1年和4年随访时评估,采用logistic回归模型并调整年龄、性别和基线值。
- 通过ROC曲线下面积评估预测能力,并用χ2检验比较。
主要发现
- 除IADL下降WS预测略优外,次要结局的预测无显著差异。
临床怎么用
- 在临床评估老年人慢速时,可考虑使用MPUT作为步行速度的替代或补充测量。
- MPUT和步行速度均可用于识别功能衰退风险较高的老年人。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Slowness, generally assessed by walking speed (WS), is an estimator of frailty and its outcomes. Because of potential difficulties in assessing WS, the Moberg picking-up test (MPUT) might be an alternative. This study investigated the capacity of slowness measurements (WS and MPUT) to predict nonfatal adverse consequences of frailty: primarily, decline in basic activities of daily living (BADL); and secondarily, decline in instrumental activities of daily living (IADL), fall, hospitalization, and incident disease. DESIGN: Observational (prospective longitudinal study). SETTING AND PARTICIPANTS: This study used data from the population-based Lausanne cohort 65+. At baseline, 1887 individuals (aged 72-77 years) completed both WS (time to walk 20 m at usual pace) and MPUT (time to pick up 12 objects) assessments. METHODS: All outcomes, assessed at 1- and 4-year follow-ups, were entered in separate logistic regression models with adjustment for age, sex, and respective values at baseline. The prediction of all outcomes by either WS or MPUT was assessed using area under the receiver operating characteristic curve and compared by χ2 tests. RESULTS: There were positive associations between slowness either assessed by WS [relative risk (RR) = 2.48; P < .001] or MPUT (RR = 1.91; P < .001) and decline in BADL at 1-year follow-up. These associations remained significant at 4-year follow-up for both WS (RR = 2.28; P < .001) and MPUT (RR = 1.95; P < .001). There was no significant difference between predictive values of slow WS and MPUT for decline in BADL at 1-year (P = .328) and 4-year follow-ups (P = .413). The prediction was not significantly different for secondary outcomes, except for decline in IADL for which the prediction was slightly better for WS. CONCLUSIONS AND IMPLICATIONS: MPUT may be an alternative measurement of slowness with predictive value of functional decline. No significant difference in predictive capabilities of MPUT and WS for specific adverse consequences of frailty is promising in favor of using MPUT for measuring slowness.
引用
- Abolhassani N, Fustinoni S, Henchoz Y, et al. Slowness as a Predictor of Functional Decline in Older Adults: Comparison of Moberg Picking-Up Test and Walking Speed. J Am Med Dir Assoc. 2022. PMID: 35995094. doi:10.1016/j.jamda.2022.07.016