文献速递老年慢病共病管理

持续体温监测在老年集体居住机构中的可行性、可接受性与性能

Feasibility, Acceptability, and Performance of a Continuous Temperature Monitor in Older Adults and Staff in Congregate-Living Facilities.
PubMed 文献 · J Am Med Dir Assoc · 2022-04-06

结果显示居民完成率80%,工作人员100%,设备数据获取率远高于手动测温,并检测到4次手动测温未发现的发热事件。结论认为持续体温监测在老年集体居住机构中可行且可接受,能更早发现发热。

要点

  • 持续体温监测在老年居民和工作人员中可行且可接受。
  • 设备数据获取率远高于手动测温,并检测到手动未发现的发热。
  • 居民完成率80%,工作人员完成率100%。

核心结论

  • 在老年集体居住机构中,持续体温监测对居民和工作人员均可行且可接受,并能发现标准护理未检测到的发热。

主要发现

  • 80%的居民参与者完成研究(20/25),工作人员完成率和重新佩戴率均为100%。
  • 首次重新佩戴时,91.3%的居民(21/23)无需帮助即可佩戴设备。
  • 持续体温设备的数据获取率远高于手动测温。
  • 设备检测到4次发热事件,而手动体温检查未识别这些事件。

临床怎么用

  • 在老年集体居住机构中可考虑使用持续体温监测设备,以弥补手动测温的不足并更早发现发热。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Residents of congregate-living facilities are susceptible to disability and mortality from infection given the presence of advanced age, multimorbidity, and frailty-as demonstrated in the recent COVID pandemic. This study assessed the feasibility, acceptability, and applicability of a continuous temperature monitoring device in a congregate-living facility with residents of independent living, assisted living, and their care-providing staff. We hypothesized that a wearable device compared with daily manual temperature assessment would be well tolerated and more effective at detecting temperature variances than current standard of care body temperature assessment. DESIGN: Feasibility study. SETTING AND PARTICIPANTS: Residents of assisted and independent living and staff of a retirement community. METHODS: Thirty-five participants, including residents in assisted- and independent-living facilities (25) and staff (10) were enrolled in a 90-day feasibility study and wore a continuous temperature sensor from March to July 2021. Primary outcomes included study completion, ability to reapply the sensor, temperature data acquisition, and data availability from the sensors. A secondary analysis of the temperature data involved comparing the method of obtaining temperature using the continuous monitoring device against standard of care using traditional manual thermometers. RESULTS: Overall, 91.3% of residents, who were in the study during the first reapplication, were able to apply the device without assistance (21 of 23), and 80% of resident participants completed the study (20 of 25). For staff participants, completion rates and reapplication rates were 100%. Data acquisition rates from the continuous temperature devices were much higher than manual temperatures. Four episodes of fever were detected by the devices; manual temperature checks did not identify these events. CONCLUSIONS AND IMPLICATIONS: Continuous temperature monitoring in an older adult population and the staff in congregate-living facilities is feasible and acceptable. This approach identified fever undetected by current standard of care indicating the capability of this device for earlier detection of fevers.

来源:J Am Med Dir Assoc,查看原文。版权归原作者所有。

引用

  1. Kirkendall ES, McCraw J, Ganesh S, et al. Feasibility, Acceptability, and Performance of a Continuous Temperature Monitor in Older Adults and Staff in Congregate-Living Facilities. J Am Med Dir Assoc. 2022. PMID: 35395218. doi:10.1016/j.jamda.2022.03.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。