文献速递老年综合评估认知障碍与谵妄

长期护理机构中抑郁检测工具的诊断准确性:系统综述与meta分析

Detecting depression in persons living in long-term care: a systematic review and meta-analysis of diagnostic test accuracy studies.
PubMed 文献 · Age Ageing · 2022-01-01

该系统综述与meta分析检索了截至2021年9月10日的文献,纳入20项研究,评估长期护理机构中抑郁检测工具的诊断准确性。共识别23种经验证的抑郁检测工具,其中GDS-15研究最多,在切点6时合并敏感度73.6%、特异度76.5%、AUC 0.83,但存在显著异质性。

要点

  • GDS-15切点6时合并敏感度73.6%、特异度76.5%、AUC 0.83。
  • NH-SDI敏感度范围40.0%–98.0%,CSDD-4对痴呆患者敏感度最高67.0%–90.0%。
  • 共23种工具经验证,但除GDS-15外其他工具数据不足以进行meta分析。

核心结论

  • 长期护理机构中有23种抑郁检测工具经验证,GDS-15研究最多,NH-SDI和CSDD-4为更简短的选项,但需更多研究进行meta分析验证准确性。

研究设计与样本

  • 系统综述与诊断准确性meta分析,检索PubMed、EMBASE、PsycINFO和CINAHL自建库至2021年9月10日,纳入20项研究(19项进入meta分析),使用QUADAS-2评估偏倚风险。

主要发现

  • 共识别23种抑郁检测工具(含不同版本)经参考标准验证。
  • GDS-15切点6时合并敏感度73.6%(95%CI 43.9%-76.5%),特异度76.5%(95%CI 62.9%-86.7%),AUC 0.83,存在显著异质性。
  • NH-SDI敏感度范围40.0%–98.0%。
  • CSDD-4对长期护理机构中痴呆患者敏感度最高(67.0%–90.0%)。
  • 其他筛查工具数据不足以进行meta分析。

关键数值与推荐

  • GDS-15切点6:敏感度73.6%(95%CI 43.9%-76.5%),特异度76.5%(95%CI 62.9%-86.7%),AUC 0.83。
  • NH-SDI敏感度范围40.0%–98.0%。
  • CSDD-4对痴呆患者敏感度67.0%–90.0%。

临床怎么用

  • 长期护理机构中可选用GDS-15(切点6)筛查抑郁,但需注意异质性。
  • 对痴呆患者可考虑CSDD-4,其敏感度较高。
  • NH-SDI可作为简短筛查选项,但准确性证据有限。

局限性

  • GDS-15分析存在显著异质性。
  • 除GDS-15外其他工具数据不足以进行meta分析。
  • NH-SDI和CSDD-4需更多研究以meta分析评估准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Depressive disorders are common in long-term care (LTC), however, there is no one process used to detect depressive disorders in this setting. Our goal was to describe the diagnostic accuracy of depression detection tools used in LTC settings. METHODS: We conducted a systematic review and meta-analysis of diagnostic accuracy measures. The databases PubMed, EMBASE, PsycINFO and CINAHL were searched from inception to 10 September 2021. Studies involving persons living in LTC, assisted living residences or facilities, comparing diagnostic accuracy of depression tools with a reference standard, were included. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was used to assess risk of bias. RESULTS: We identified 8,463 citations, of which 20 studies were included in qualitative synthesis and 19 in meta-analysis. We identified 23 depression detection tools (including different versions) that were validated against a reference standard. At a cut-off point of 6 on the Geriatric Depression Scale-15 (GDS-15), the pooled sensitivity was 73.6% (95% confidence interval (CI) 43.9%-76.5%), specificity was 76.5% (95% CI 62.9%-86.7%), and an area under the curve was 0.83. There was significant heterogeneity in these analyses. There was insufficient data to conduct meta-analysis of other screening tools. The Nursing Homes Short Depression Inventory (NH-SDI) had a sensitivity ranging from 40.0% to 98.0%. The 4-item Cornell Scale for Depression in Dementia (CSDD) had the highest sensitivity (67.0%-90.0%) for persons in LTC living with dementia. CONCLUSIONS: There are 23 tools validated for detection of depressive disorders in LTC, with the GDS-15 being the most studied. Tools developed specifically for use in LTC settings include the NH-SDI and CSDD-4, which provide briefer options to screen for depression. However, more studies of both are needed to examine tool accuracy using meta-analyses.