文献速递疝与腹壁外科

新一代疝修补假体材料在腹膜界面的行为研究

Behaviour at the peritoneal interface of next-generation prosthetic materials for hernia repair.
PubMed 文献 · Surg Endosc · 2021-01-28

该临床前研究在兔模型中比较了全降解Phasix-ST®、部分降解Symbotex®与聚丙烯对照网片在腹膜界面的表现;两种复合材料在各时间点粘连均显著减少且以疏松为主,Symbotex粘连少于Phasix,但Phasix新生腹膜更厚且M2修复型标志物表达更高。

要点

  • 两种复合材料在3至90天各时间点粘连均显著少于聚丙烯对照,且以疏松粘连为主。
  • Symbotex形成的粘连少于Phasix,7天起两者差异显著且Phasix随时间增加。
  • Phasix新生腹膜显著更厚且组织成熟,M2修复型标志物IL-10表达更高。

核心结论

  • Symbotex植入后形成的粘连少于Phasix。
  • 植入90天后Symbotex总巨噬细胞计数显著更高,但Phasix的M2修复相关标志物表达更高。

研究设计与样本

  • 临床前研究,采用新西兰白兔模型。
  • 比较全降解Phasix-ST®与部分降解Symbotex®两种复合材料,以聚丙烯网片Optilene®为对照。
  • 于3至90天行连续腹腔镜监测粘连形成,并进行新生腹膜形态学研究。
  • 通过免疫组化标记总巨噬细胞,qRT-PCR检测M1(TNF-α/CXCL9)与M2(MRC1/IL-10)巨噬细胞表型。

主要发现

  • 对照组坚硬且整合的粘连百分比随时间持续很高。
  • 两种复合材料在所有研究时间点粘连均显著减少,定性上以疏松为主。
  • 两种复合材料自7天起差异显著,Phasix粘连值随时间增加。
  • Phasix新生腹膜厚度显著大于其他网片,显示成熟且有序的新生结缔组织。
  • 免疫组化显示Symbotex巨噬细胞百分比显著更高;M2修复型巨噬细胞mRNA表达Phasix最高,但仅IL-10差异显著。

临床怎么用

  • 选择复合材料时需权衡粘连形成与新生腹膜修复质量,Symbotex粘连更少而Phasix修复型标志物表达更高。

局限性

  • 研究为兔临床前模型,结果外推至人体需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: When using a prosthetic material in hernia repair, the behaviour of the mesh at the peritoneal interface is especially important for implant success. Biomaterials developed for their intraperitoneal placement are known as composites and are made up of two different-structure materials, one is responsible for good integration within host tissue and the other is responsible to make contact with the viscera. This study examines the behaviour at the peritoneal level of two composites, the fully degradable Phasix-ST® and the partially degradable Symbotex®. A polypropylene mesh (Optilene®) served as control. METHODS: Sequential laparoscopy from 3 to 90 days, in a preclinical model in the New Zealand white rabbit, allowed monitoring adhesion formation. Morphological studies were performed to analyse the neoperitoneum formed in the repair process. Total macrophages were identified by immunohistochemical labelling. To identify the different macrophage phenotypes, complementary DNAs were amplified by qRT-PCR using specific primers for M1 (TNF-α/CXCL9) and M2 (MRC1/IL-10) macrophages. RESULTS: The percentage of firm and integrated adhesions remained very high in the control group over time. Both composites showed a significant decrease in adhesions at all study times and in qualitative terms were mainly loose. Significant differences were also observed from 7 days onwards between the two composites, increasing the values in Phasix over time. Neoperitoneum thickness for Phasix was significantly greater than those of the other meshes, showing mature and organized neoformed connective tissue. Immunohistochemically, a significantly higher percentage of macrophages was observed in Symbotex. mRNA expression levels for the M2 repair-type macrophages were highest for Phasix but significant differences only emerged for IL-10. CONCLUSIONS: Fewer adhesions formed to the Symbotex than Phasix implants. Ninety days after implant, total macrophage counts were significantly higher for Symbotex, yet Phasix showed the greater expression of M2 markers related to the tissue repair process.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Pascual G, Benito-Martínez S, Rodríguez M, et al. Behaviour at the peritoneal interface of next-generation prosthetic materials for hernia repair. Surg Endosc. 2021. PMID: 33507384. doi:10.1007/s00464-021-08320-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。