文献速递胃肠外科

术中ICG荧光成像评估预防左半结肠或直肠癌术后吻合口漏的倾向性评分匹配分析

Efficacy of intraoperative ICG fluorescence imaging evaluation for preventing anastomotic leakage after left-sided colon or rectal cancer surgery: a propensity score-matched analysis.
PubMed 文献 · Surg Endosc · 2021-01-25

该研究回顾性分析前瞻性收集的数据,比较ICG荧光成像组(197例)与历史对照组(187例)左半结肠或直肠切除术后吻合口漏(AL)发生率,倾向性评分匹配后各93例,ICG组AL率显著低于对照组(3.2% vs 10.8%,P=0.046)。

要点

  • ICG荧光成像评估吻合口近端肠管灌注可显著降低左半结肠或直肠术后AL发生率。
  • 倾向性评分匹配后ICG组AL率为3.2%,历史对照组为10.8%(P=0.046)。
  • 灌注不良/无灌注患者即使改变切断线,AL发生率仍显著高于灌注良好者(16.7% vs 灌注良好者,P=0.038)。

核心结论

  • 术中ICG荧光成像评估可显著降低左半结肠或直肠切除术后吻合口漏发生率。

研究设计与样本

  • 回顾性分析前瞻性收集数据,ICG组197例,历史对照组187例,行倾向性评分匹配分析。

主要发现

  • ICG组AL发生6例(3.3%),历史对照组17例(10.7%)。
  • ICG评估显示179例灌注良好,18例(9.1%)灌注不良/无灌注,后者均改变切断线。
  • 灌注不良/无灌注患者中3例(16.7%)发生AL,发生率显著高于灌注良好患者(P=0.038)。
  • 倾向性评分匹配后每组93例,ICG组AL率显著低于历史对照组(3.2% vs 10.8%,P=0.046)。

临床怎么用

  • 左半结肠或直肠切除术中可用ICG荧光成像评估吻合口近端肠管灌注,灌注不足时改变切断线。

局限性

  • 研究为前瞻性收集数据但回顾性分析,存在比较局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intestinal perfusion at the anastomotic site is thought to be one of the most influential risk factors for postoperative anastomotic leakage (AL). We evaluated the efficacy of indocyanine green (ICG) fluorescence imaging at the stump of the proximal colon in left-sided colectomy or rectal resection in terms of decreasing the incidence of AL. METHODS: Prospectively collected data were retrospectively evaluated. Patients who underwent left-sided colectomy or rectal resection were enrolled (ICG group; n = 197), and patients who had undergone a similar procedure before the ICG group were enrolled from the charts as historical controls (HC group; n = 187). After ICG evaluation, anastomosis was performed where fluorescence was sufficient. The incidence of AL was compared between the ICG and HC groups. Propensity score (PS)-matched data were analyzed to clarify the risk of AL. RESULTS: AL occurred in 6 patients (3.3%) in the ICG group and 17 (10.7%) in the HC group. ICG evaluation revealed 179 patients with good fluorescence and 18 with poor/none perfusion (9.1%). The transection line was changed in all patients with poor/none fluorescence. Three of these 18 patients developed AL (16.7%), though transection line was changed at which is thought to be good. We hope AL in poor/none fluorescence can be prevented at the same rate of cases with good fluorescence. Actually, the rate of that was significantly higher compared with good fluorescence patients (P = 0.038). 93 patients in each group were compared by PS-matched data analysis, which showed the AL rate in the ICG group was significantly lower than that in the HC group (3.2% vs 10.8%, respectively; P = 0.046). CONCLUSIONS: Even though this study has limitations of comparison of data prospectively collected and retrospectively analyzed, intraoperative ICG fluorescence imaging evaluation could significantly decrease the incidence of AL.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Yanagita T, Hara M, Osaga S, et al. Efficacy of intraoperative ICG fluorescence imaging evaluation for preventing anastomotic leakage after left-sided colon or rectal cancer surgery: a propensity score-matched analysis. Surg Endosc. 2021. PMID: 33495878. doi:10.1007/s00464-020-08230-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。