文献速递乳腺外科围术期管理与 ERAS

前哨淋巴结活检蓝染剂过敏反应率:系统综述与荟萃分析

Anaphylactic Reaction Rates to Blue Dyes Used for Sentinel Lymph Node Mapping: Systematic Review and Meta-analysis.
PubMed 文献 · Ann Surg · 2021-01-01

乳腺癌SLNB过敏风险为0.083%,黑色素瘤手术为0.0043%;低染料体积(<2 mL)和皮内注射与更低过敏率相关,异硫蓝过敏原性最高(0.16%),队列中无死亡报告。

要点

  • SLNB蓝染剂总体过敏反应率为0.061%,属罕见事件。
  • 乳腺癌SLNB过敏风险0.083%,明显高于黑色素瘤手术的0.0043%。
  • 低体积(<2 mL)和皮内注射过敏率更低,异硫蓝过敏原性最高。

核心结论

  • SLNB中使用蓝染剂发生过敏反应罕见,亚甲蓝、专利蓝、低染料体积和皮内给药均与更低过敏发生率相关。

主要发现

  • 乳腺癌SLNB过敏风险为0.083%,黑色素瘤手术为0.0043%。
  • 低染料体积(<2 mL)过敏率为0.031%,皮内注射为0.0068%。
  • 异硫蓝过敏率为0.16%,在本队列中未见死亡病例报告。

关键数值与推荐

  • SLNB蓝染剂总体加权过敏反应率为0.061%。
  • 乳腺癌SLNB过敏风险0.083%,黑色素瘤手术0.0043%。
  • 低染料体积(<2 mL)过敏率0.031%,皮内注射0.0068%。
  • 异硫蓝过敏率0.16%。

临床怎么用

  • 临床选择SLNB蓝染剂时可优先考虑亚甲蓝或专利蓝,并采用低体积(<2 mL)和皮内注射以降低过敏风险。
  • 对乳腺癌SLNB患者应知晓其过敏风险高于黑色素瘤手术,异硫蓝过敏原性较高需谨慎使用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The primary objective of this study was to quantify the risk of anaphylaxis to blue dyes used in SLNB for cancer. Secondary outcomes included the identification of factors that may influence this risk. SUMMARY OF BACKGROUND DATA: Blue dyes are widely used to help identify sentinel lymph nodes in oncological surgery. The rate of severe allergic reactions to blue dyes remains a controversial topic, with the true incidence and influencing factors uncertain. METHODS: A systematic review and meta-analysis was performed to identify all studies which report on the incidence of severe adverse reactions and anaphylaxis to blue dyes (patent blue, isosulfan blue, methylene blue, and indigo carmine), when used for SLNB. Collected data included cancer and dye type, volume, and method of injection. Incidence was estimated using the arcsine method of statistical analysis. RESULTS: One hundred nine studies documenting 94 episodes of anaphylaxis in a total of 61,951 SLNB procedures, resulting in a weighed anaphylaxis rate of 0.061%. SLNB for breast cancer carries an anaphylaxis risk of 0.083%, with the risk markedly lower in melanoma surgery (0.0043%). Low dye volume (<2 mL) and intradermal injection are both associated with lower rates of anaphylaxis (0.031% and 0.0068%). Isosulfan blue seems to be the most anaphylactogenic amongst blue dyes with a rate of 0.16%. There were no reported cases of death in this cohort. CONCLUSION: Anaphylaxis to blue dyes in SLNB is rare. Methylene blue, patent blue, lower dye volumes, and intradermal administration are all associated with a lower incidence of anaphylaxis.

来源:Ann Surg,查看原文。版权归原作者所有。

引用

  1. Perenyei M, Barber ZE, Gibson J, et al. Anaphylactic Reaction Rates to Blue Dyes Used for Sentinel Lymph Node Mapping: Systematic Review and Meta-analysis. Ann Surg. 2021. PMID: 33055586. doi:10.1097/SLA.0000000000004061

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。