精准图像引导结肠手术:术前与术中血管成像的初步验证
该研究在6头猪中验证了术前CT血管三维重建规划联合术中动脉内荧光成像引导结肠切除的可行性。选择性插管平均耗时43分钟,荧光成像可清晰显示目标血管与肠段灌注,软件可定量分析最佳切除边缘。该方法安全可行,有望精准确定基于灌注的切除平面。
要点
- 术前CT血管三维重建可规划基于血管的切除线
- 术中动脉内ICG荧光成像能清晰标记目标血管与肠段灌注
- 定量软件分析可提示各感兴趣区的最佳切除边缘
核心结论
- 动脉内荧光成像可显示主要血管结构和节段性结肠灌注,可能有助于避免大血管误伤并精准确定基于灌注的切除平面和边缘。
研究设计与样本
- 在6头猪中进行的可行性验证研究,术前CT血管三维重建规划,在杂交手术室行腹腔镜手术,对肠系膜上动脉或肠系膜下动脉分支行超选择性动脉插管。
主要发现
- 该方法是可行且安全的,选择性插管平均耗时43分钟。
- 团注和持续输注吲哚菁绿均能清晰标记预先识别的血管(动脉/静脉)和目标结肠段,便于基于可见血管解剖进行精准切除。
- 定量软件分析可指示每个感兴趣区的最佳切除边缘。
关键数值与推荐
- 术中经动脉给予吲哚菁绿团注剂量为0.1 mg/kg或持续输注浓度为0.01 mg/mL,用于引导荧光辅助的乙状结肠和回盲部切除。
临床怎么用
- 该技术可能帮助外科医生在结肠手术中避免误伤主要血管,并根据灌注情况精准确定切除平面和边缘,从而可能个体化切除范围、确保吻合口灌注并改善肿瘤学结局。
局限性
- 研究为动物实验(6头猪),样本量小,结论需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Colorectal surgery has benefited from advances in precision medicine such as total mesorectal resection, and recently, mesocolon resection, fluorescent perfusion imaging, and fluorescent node mapping. However, these advances fail to address the variable quality of mesocolon dissection and the directed extent of vascular dissection (including high ligation) or pre-resection anastomotic perfusion mapping, thereby impacting anastomotic leaks. We propose a new paradigm of precision image-directed colorectal surgery involving 3D preoperative resection modeling and intraoperative fluoroscopic and fluorescence vascular imaging which better defines optimal dissection planes and vascular vs. anatomy-based resection lines according to our hypothesis. METHODS: Six pigs had preoperative CT with vascular 3D reconstruction allowing for the preoperative planning of vascular-based dissection. Laparoscopic surgery was performed in a hybrid operating room (OR). Superselective arterial catheterization was performed in branches of the superior mesenteric artery (SMA) or the inferior mesenteric artery (IMA). Intraoperative boluses of 0.1 mg/kg or a continuous infusion of indocyanine green (ICG) (0.01 mg/mL) were administered to guide fluorescent-based sigmoid and ileocecal resections. Fluorescence was assessed using proprietary software at several regions of interest (ROI) in the right and left colon. RESULTS: The approach was feasible and safe. Selective catheterization took an average of 43 min. Both bolus and continuous perfusion clearly marked pre-identified vessels (arteries/veins) and the target colon segment, facilitating precise resections based on the visible vascular anatomy. Quantitative software analysis indicated the optimal resection margin for each ROI. CONCLUSION: Intra-arterial fluorescent mapping allows visualization of major vascular structures and segmental colonic perfusion. This may help to prevent any inadvertent injury to major vascular structures and to precisely determine perfusion-based resection planes and margins. This could enable tailoring of the amount of colon resected, ensure good anastomotic perfusion, and improve oncological outcomes.
引用
- Forgione A, Barberio M, Agnus V, et al. Precision image-guided colonic surgery: proof of concept for enhanced preoperative and intraoperative vascular imaging. Surg Endosc. 2020. PMID: 32997271. doi:10.1007/s00464-020-08000-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。