机器人减重手术中手术时间与群体 sourcing 技能评估的相关性
结果显示总体手术时间与GEARS总分无相关性(R²=0.0146,p=0.326),仅胃横断步骤时间与评分呈弱相关(R²=0.0737,p=0.028)。结论认为手术时间与GEARS评分测量不同的手术表现特征。
要点
- 手术时间与GEARS总分无显著相关性(R²=0.0146,p=0.326)
- 仅胃横断步骤时间与评分呈弱相关(R²=0.0737,p=0.028)
- 建议联合使用技能评估工具和手术时间全面评价手术技能
核心结论
- 手术时间与群体 sourcing 的GEARS评分无相关性,两者测量不同的手术表现特征。
主要发现
- 平均手术时间112±27.4分钟,平均GEARS总分20.1±0.81。
- 手术时间与GEARS总分无相关性(R²=0.0146,p=0.326)。
- 胃横断步骤时间与评分呈弱相关(R²=0.0737,p=0.028),其余步骤无相关性。
临床怎么用
- 临床评估机器人减重手术技能时,不应仅依赖手术时间,应结合经验证的技能评估工具如GEARS。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Operative time has been traditionally used as a proxy for surgical skill and is commonly utilized to measure the learning curve, assuming that faster operations indicate a more skilled surgeon. The Global Evaluative Assessment of Robotic Skills (GEARS) rubric is a validated Likert scale for evaluating technical skill. We hypothesize that operative time will not correlate with the GEARS score. METHODS: Patients undergoing elective robotic sleeve gastrectomy at a single bariatric center of excellence hospital from January 2019 to March 2020 were captured in a prospectively maintained database. For step-specific scoring, videos were broken down into three steps: ligation of short gastric vessels, gastric transection, and oversewing the staple line. Overall and step-specific GEARS scores were assigned by crowd-sourced evaluators. Correlation between operative time and GEARS score was assessed with linear regression and calculation of the R2 statistic. RESULTS: Sixty-eight patients were included in the study, with a mean operative time of 112 ± 27.4 min. The mean GEARS score was 20.1 ± 0.81. Mean scores for the GEARS subcomponents were: bimanual dexterity 4.06 ± 0.17; depth perception 3.96 ± 0.24; efficiency 3.82 ± 0.19; force sensitivity 4.06 ± 0.20; robotic control 4.16 ± 0.21. Operative time and overall score showed no correlation (R2 = 0.0146, p = 0.326). Step-specific times and scores showed weak correlation for gastric transection (R2 = 0.0737, p = 0.028) and no correlation for ligation of short gastric vessels (R2 = 0.0262, p = 0.209) or oversewing the staple line (R2 = 0.0142, p = 0.344). CONCLUSIONS: Operative time and crowd-sourced GEARS score were not correlated. Operative time and GEARS scores measure different performance characteristics, and future studies should consider using both a validated skills assessment tool and operative time for a more complete evaluation of skill.
引用
- Addison P, Yoo A, Duarte-Ramos J, et al. Correlation between operative time and crowd-sourced skills assessment for robotic bariatric surgery. Surg Endosc. 2020. PMID: 32970207. doi:10.1007/s00464-020-08019-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。