文献速递肝胆胰外科围术期管理与 ERAS

肝下下腔静脉部分阻断对腹腔镜肝切除中心静脉压及术中出血的影响

Effect of infrahepatic inferior vena cava partial clamping on central venous pressure and intraoperative blood loss during laparoscopic hepatectomy.
PubMed 文献 · Surg Endosc · 2020-06-30

该回顾性研究纳入2014年9月至2019年8月连续接受腹腔镜肝切除术的患者,评估肝下下腔静脉部分阻断的有效性与安全性。结果显示阻断后中心静脉压显著下降且血流动力学稳定,但总体出血量未显著减少;亚组分析中中重度肝硬化患者出血量显著减少,并发症与住院时间无差异。

要点

  • 肝下下腔静脉部分阻断可显著降低腹腔镜肝切除中的中心静脉压。
  • 总体出血量未显著减少,但中重度肝硬化患者出血量显著减少。
  • 阻断未增加并发症或延长住院时间,血流动力学稳定。

核心结论

  • 肝下下腔静脉部分阻断在腹腔镜肝切除中可能安全有效。

研究设计与样本

  • 回顾性研究,连续纳入2014年9月至2019年8月拟行腹腔镜肝切除术的患者。

主要发现

  • 阻断组中心静脉压由8.7 ± 1.4 cmH2O降至2.1 ± 1.3 cmH2O(P = 0.000),无血流动力学不稳定。
  • 阻断组与非阻断组总出血量分别为287.3 ± 112.5 mL与301.4 ± 127.6 mL(P = 0.133),肝实质离断期出血量分别为273.2 ± 107.9 mL与296.5 ± 118.1 mL(P = 0.618)。
  • 中重度肝硬化患者中,阻断组总出血量363.6 ± 71.2 mL vs 473.4 ± 95.6 mL(P = 0.021),肝实质离断期出血量358.7 ± 70.9 mL vs 466.9 ± 94.5 mL(P = 0.016)。
  • 并发症与住院时间两组相当。

临床怎么用

  • 可考虑在腹腔镜肝切除中应用肝下下腔静脉部分阻断以降低中心静脉压,尤其对中重度肝硬化患者可能减少出血。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Infrahepatic inferior vena cava (IVC) clamping is considered to be an effective method to reduce central venous pressure (CVP) and intraoperative bleeding in liver resection. However, its efficacy and safety during laparoscopic hepatectomy (LH) remain unclear. We perform this retrospective study to evaluate its efficacy and safety during LH. METHODS: Consecutive patients scheduled for LH from September 2014 to August 2019 were retrospectively reviewed. The intraoperative parameters and postoperative outcomes were analyzed. RESULTS: All patients in the infrahepatic IVC clamping group were able to tolerate partial clamping of IVC. The CVP was significantly decreased after infrahepatic IVC clamping without hemodynamic instability (8.7 ± 1.4 cmH2O vs. 2.1 ± 1.3 cmH2O, P = 0.000). Infrahepatic IVC clamping did not significantly reduce total blood loss (287.3 ± 112.5 mL vs. 301.4 ± 127.6 mL, P = 0.133) and blood loss during parenchymal transection (273.2 ± 107.9 mL vs. 296.5 ± 118.1 mL, P = 0.618) compared with the non-clamping group. In subgroup analysis, total blood loss and blood loss during parenchymal transection were significantly reduced in patients with moderate to severe cirrhosis in the clamping group (363.6 ± 71.2 mL vs. 473.4 ± 95.6 mL, P = 0.021), (358.7 ± 70.9 mL vs. 466.9 ± 94.5 mL, P = 0.016), respectively. The complications and hospital stay were comparable. CONCLUSIONS: In conclusion, these data suggest that infrahepatic IVC clamping may be safe and effective.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Xiao LK, Huang P, Wu K, et al. Effect of infrahepatic inferior vena cava partial clamping on central venous pressure and intraoperative blood loss during laparoscopic hepatectomy. Surg Endosc. 2020. PMID: 32607902. doi:10.1007/s00464-020-07709-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。