新型离体多器官腹腔镜训练平台Smagister的初步评估
本研究设计了一种新型离体多器官模拟器Smagister,由常温机器灌注平台、猪腹腔多器官、高清显示和软件系统组成,并记录血气分析、每小时蠕动次数及器官活力问卷。在平台完成腹腔镜胆囊切除、肠切开缝合和肝切除,演示特定事件,6名专家对比实际手术评估可行性与并发症展示。灌注液葡萄糖(6.1-8.2 mmol/L)和乳酸(5.82-6.55 mmol/L)波动提示多器官代谢功能,平均蠕动2.2次/分,模拟手术视野和解剖结构接近实际手术(评分3.5±1.0、3.8±0.8),触觉反馈评分3.8±0.8,6名专家均认为适合基础和高级腹腔镜训练。
要点
- Smagister由常温机器灌注平台、猪腹腔多器官、高清显示和软件系统组成。
- 灌注液葡萄糖和乳酸波动提示多器官代谢功能,平均蠕动2.2次/分。
- 6名专家认为Smagister适合基础和高级腹腔镜手术训练。
核心结论
- Smagister结合活体动物模型和离体模拟的优点,扩展训练领域,为新手和资深外科医生提供高保真腹腔镜训练。
研究设计与样本
- 设计新型离体模拟器Smagister,由常温机器灌注平台、猪腹腔多器官、高清显示和软件系统组成。
- 记录血气分析和每小时蠕动次数,每小时用问卷主观评估器官簇活力。
- 在Smagister上完成腹腔镜胆囊切除(LC)、肠切开缝合(LEC)和肝切除(LLR),演示特定事件。
- 6名专家从完成可行性和并发症展示方面与实际手术对比评估。
主要发现
- 灌注液葡萄糖(6.1-8.2 mmol/L)和乳酸(5.82-6.55 mmol/L)波动提示多器官代谢功能。
- 平均蠕动次数为2.2次/分。
- 持续灌注期间模拟手术视野和解剖结构接近实际手术,评分分别为3.5±1.0和3.8±0.8。
- 触觉反馈评估评分为3.8±0.8,类似活组织操作。
- LC、LEC和LLR在Smagister上完成良好,清晰展示特定事件,6名专家均认为适合基础和高级腹腔镜手术训练。
临床怎么用
- Smagister可作为基础和高级腹腔镜手术的高保真训练平台,适用于新手和资深外科医生。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Various training models have been developed for laparoscopic training. Inanimate models including cadavers, ex-vivo simulator, and virtual reality (VR), are less realistic and often fail to display specific events such as bleeding, bile leakage, etc. Animal models provide more realistic experience, but constraints like cost involved, anesthetic requirement, and ethical approval have limited its application. We have designed a new training ex-vivo simulator-Smagister to address these issues. METHODS: The Smagister consists of a normothermic machine perfusion platform, multivisceral organ of porcine abdominal cavity (liver, gallbladder, pancreas, stomach, intestine, kidney, uterus, bladders, etc.), high-definition display, and software system. Blood gas analysis and number of peristalsis per hour were recorded. A questionnaire was used to subjectively assess vitality of the organ cluster every hour. Three laparoscopic procedures including cholecystectomy (LC), enterotomy closure (LEC) and hepatectomy (LLR) were performed on Smagister, with demonstration of specific events for each procedure. Six experts compared the procedures with actual surgery in terms of feasibility to complete procedures and demonstration of complications. RESULTS: The fluctuation of perfusate glucose (6.1-8.2 mmol/L) and lactate (5.82-6.55 mmol/L) suggested metabolic function of the multivisceral organs. The mean number of peristalsis was 2.2/min. The simulated surgical view and anatomic structures closely resembled actual surgery during continuous perfusion (3.5 ± 1.0, 3.8 ± 0.8, respectively). The evaluation scores of haptic feedbacks were 3.8 ± 0.8, resembling live tissue handling. LC, LEC, and LLR were performed well on the Smagister, with clear display of the specific events. All six experts considered Smagister as a suitable training modality for both basic and advanced laparoscopic surgery. CONCLUSION: The amalgamation of live animal model and ex-vivo simulation in Smagister centralizes the virtue of both modalities, expands the training field, and provides high-fidelity laparoscopic training for both novice and senior surgeons.
引用
- Wang X, Zhang K, Hu W, et al. A new platform for laparoscopic training: initial evaluation of the ex-vivo live multivisceral training device. Surg Endosc. 2020. PMID: 32415369. doi:10.1007/s00464-020-07411-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。