腔内吲哚菁绿用于减重手术术中吻合线漏检测
该回顾性队列研究对比了腔内吲哚菁绿(ICG)法与胃镜法在减重手术中检测吻合线漏的效果,ICG法共59例,胃镜法共196例。ICG法敏感性100.00%、特异性98.28%,与术中胃镜特异性相当。
要点
- ICG法敏感性100.00%、特异性98.28%
- 胃镜法196例中3例假阴性
- ICG法59例中1例真阳性、1例假阳性
核心结论
- 腔内ICG是减重手术术中检测吻合线完整性的替代方法,特异性与术中胃镜相当。
研究设计与样本
- 回顾性队列研究,纳入同一术者在三级减重手术卓越中心完成的Roux-en-Y胃旁路术或袖状胃切除术患者。
- 按手术日期分为ICG方案实施前(2016年9月至2018年10月中)的胃镜法组和实施后(2018年10月中至2019年3月)的ICG法组。
主要发现
- 胃镜法组196例中3例假阴性、193例真阴性。
- ICG法组59例中1例真阳性、1例假阳性、0例假阴性、57例真阴性。
- ICG法敏感性100.00%、特异性98.28%。
关键数值与推荐
- ICG法:稀释ICG经口胃管在胃吻合线位置腔内注射,腹腔侧近红外成像观察荧光外渗。
- ICG法敏感性100.00%、特异性98.28%。
临床怎么用
- 减重手术中可采用腔内ICG注射联合近红外成像替代术中胃镜检测吻合线漏。
局限性
- 回顾性设计,单术者、单中心,样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Bariatric surgical procedures have recognized benefits for morbidly obese patients. Unfortunately, staple line leaks remain a profound complication after these procedures. Currently available intraoperative surveillance modalities have multiple drawbacks, such as requiring an available upper endoscope and experienced endoscopist. Additionally, increased procedure time and resources are needed to perform intraoperative endoscopy and maintain equipment. METHODS: This is a retrospective cohort study of all bariatric patients undergoing Roux-en-Y gastric bypass or sleeve gastrectomy procedures performed by one attending surgeon at a tertiary care facility designated as a bariatric surgical center of excellence. Patients were grouped based on procedure date being before (September 2016 to mid-October 2018) or after (mid-October 2018 to March 2019) implementation of a novel intraluminal indocyanine green leak testing protocol. Diluted indocyanine green was injected via orogastric bougie intraluminally at the location of the gastric staple line and observed with near-infrared imaging from the intraperitoneal perspective for evidence of immunofluorescence extravasation. Data from the electronic medical record and bariatric surgical outcomes database were gathered to analyze the sensitivity and specificity of this new intraoperative diagnostic modality. RESULTS: Total of 196 patients underwent bariatric surgery with intraoperative leak testing using the gastroscopy method; of these, there were 3 false negatives and 193 true negatives. Total of 59 patients underwent bariatric surgery with intraoperative leak testing using the intraluminal ICG method; of these, there was 1 true positive, 1 false positive, 0 false negatives, and 57 true negatives. Indocyanine green leak testing had a sensitivity of 100.00% and specificity of 98.28%. CONCLUSIONS: Intraluminal indocyanine green is an alternative for intraoperative detection of staple line integrity during bariatric surgical procedures with comparable specificity to intraoperative gastroscopy.
引用
- Kalmar CL, Reed CM, Peery CL, et al. Intraluminal indocyanine green for intraoperative staple line leak testing in bariatric surgery. Surg Endosc. 2020. PMID: 32385707. doi:10.1007/s00464-020-07606-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。