文献速递胃肠外科围术期管理与 ERAS

克罗恩病腹腔镜小肠评估:外科医生观察者间变异性的比较研究

Video-laparoscopic assessment of the small bowel in Crohn's disease: a comparative study to evaluate surgeons' inter-observer variability.
PubMed 文献 · Surg Endosc · 2020-04-02

本研究通过调查12名评估者对8段克罗恩病腹腔镜小肠walkthrough视频的评估,发现小肠壁增厚和肠系膜脂肪包裹的观察者间一致性最高(总体一致率87.1%和82.7%),而肠系膜病变严重程度评估异质性显著。结论认为腹腔镜评估小肠壁增厚和肠系膜脂肪包裹可靠,但肠系膜病变严重程度评估需标准化。

要点

  • 腹腔镜评估小肠壁增厚和肠系膜脂肪包裹的观察者间一致性较高。
  • 肠系膜病变严重程度评估异质性显著,一致率范围33.3%至100%。
  • 狭窄和狭窄前扩张的观察者间一致性较低,需谨慎解读。

核心结论

  • 腹腔镜评估小肠壁增厚和肠系膜脂肪包裹可靠,观察者间一致率高。
  • 肠系膜病变严重程度评估存在显著异质性。

研究设计与样本

  • 由受邀结直肠外科医生委员会设计调查问卷,包含改编自METRIC研究和肠系膜病变严重程度分类的条目。
  • 将匿名腹腔镜视频(展示原发性和复发性克罗恩病回结肠切除术中小肠walkthrough)连同匿名问卷分发给委员会成员。
  • 12名评估者完成了对8段小肠walkthrough视频的评估。

主要发现

  • 小肠壁增厚评估总体一致率为87.1%(k=0.31;95% CI -0.22,0.84)。
  • 肠系膜脂肪包裹评估总体一致率为82.7%(k=0.35;95% CI -0.04,0.73)。
  • 狭窄存在评估总体一致率为75.2%(k=0.06;95% CI -0.33,0.45)。
  • 狭窄前扩张评估总体一致率为71.2%(k=0.33;95% CI 0.15,0.51)。
  • 瘘管评估总体一致率为75.3%;轻度、中度和重度肠系膜病变评估总体一致率范围为33.3%至100%。

临床怎么用

  • 腹腔镜下可较可靠地评估小肠壁增厚和肠系膜脂肪包裹,辅助术中判断。
  • 肠系膜病变严重程度评估变异大,不宜仅凭腹腔镜表现统一分级。

局限性

  • 评估者数量较少(12名),视频样本量有限(8段)。
  • 部分评估条目的kappa值置信区间较宽,一致性结论需谨慎解读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Assessment of the entire small bowel is advocated during Crohn's disease (CD) surgery, as intraoperative detection of new lesions may lead to change in the planned procedure. The aim of this study was to evaluate the inter-observer variability in the assessment of extent and severity of CD at the small bowel laparoscopic "walkthrough". METHODS: A survey on laparoscopic assessment of the small bowel in patients with CD, including items adapted from the MREnterography or ultrasound in Crohn's disease (METRIC) study and from the classification of severity of mesenteric disease was developed by an invited committee of colorectal surgeons. Anonymous laparoscopic videos demonstrating the small bowel "walkthrough" in ileocolonic resection for primary and recurrent CD were distributed to the committee members together with the anonymous survey. The primary outcome was the rate of inter-observer variability on assessment of strictures, dilatations, complications and severity of mesenteric inflammation. RESULTS: 12 assessors completed the survey on 8 small bowel walkthrough videos. The evaluation of the small bowel thickening and of the mesenteric fat wrapping were the most reliable assessments with an overall agreement of 87.1% (k = 0.31; 95% CI - 0.22, 0.84) and 82.7% (k = 0.35; 95% CI - 0.04, 0.73), respectively. The presence of strictures and pre-stenotic dilatation demonstrated agreement of 75.2% (k = 0.06: 95% CI - 0.33, 0.45) and 71.2% (k = 0.33; 95% CI 0.15, 0.51), respectively. Evaluation of fistulae had an overall agreement of 75.3%, while there was a significant variation in the evaluation of mild, moderate and severe mesenteric disease with overall agreement ranging from 33.3 to 100%. CONCLUSION: Laparoscopic assessment of the small bowel thickening and of the presence of mesenteric fat wrapping is reliable for the intraoperative evaluation of CD with high inter-rater agreement. There is significant heterogeneity in the assessment of the severity of the mesenteric disease involvement.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. V Celentano, Garofalo E, Spinelli A, et al. Video-laparoscopic assessment of the small bowel in Crohn's disease: a comparative study to evaluate surgeons' inter-observer variability. Surg Endosc. 2020. PMID: 32240380. doi:10.1007/s00464-020-07521-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。