无气腔双侧腋乳入路机器人甲状腺切除术安全性与有效性的前瞻性随机对照研究
该前瞻性随机对照试验比较无气腔与常规充气双侧腋乳入路(BABA)机器人甲状腺切除术,每组14例。两组临床病理与肿瘤学结果无显著差异,无气腔组手术时间更长(212.50±35.88 vs. 187.50±42.64 min,P=0.028),pH下降更少(P=0.047),血流动力学与疼痛参数无显著差异,无安全性问题。
要点
- 无气腔BABA机器人甲状腺切除术安全,代谢变化更小
- 无气腔组手术时间显著长于充气组
- 两组血流动力学与疼痛参数无显著差异
核心结论
- 无气腔BABA机器人甲状腺切除术安全,术中代谢变化最小化,但需谨慎使用并积累更多经验。
研究设计与样本
- 前瞻性随机对照试验,比较常规充气与无气腔BABA机器人甲状腺切除术,充气组14例,无气腔组14例。
主要发现
- 两组人口学与基线特征无显著差异。
- 两组临床病理与肿瘤学结果无显著差异。
- 无气腔组手术时间更长(212.50±35.88 vs. 187.50±42.64 min,P=0.028)。
- 无气腔组pH下降显著更少(P=0.047),HR、MAP、CO、CI、PaCO2、NRS、NA、BHC无显著组间差异。
- 无安全性问题发生。
临床怎么用
- 无气腔BABA机器人甲状腺切除术可作为安全选项,尤其关注代谢影响时,但需注意手术时间可能延长。
局限性
- 样本量较小(每组14例),需更多经验验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: During bilateral axillo-breast approach (BABA) robotic thyroidectomy (RoT), carbon dioxide (CO2) gas is insufflated into the operative cavity, not only triggering hemodynamic and metabolic changes, but also inducing postoperative pain and gas embolism. Here, we explored whether the new gasless BABA RoT approach was as safe and efficacious as conventional robotic surgery using CO2 insufflation. PATIENTS AND METHODS: We performed a prospective, randomized controlled trial comparing conventional BABA RoT to gasless BABA RoT (CO2 group, n = 14; gasless group, n = 14). All clinicopathological and oncological outcomes were evaluated. The hemodynamic parameters [heart rate (HR), mean arterial pressure (MAP), cardiac output (CO), and cardiac index (CI)] and metabolic parameters [partial pressure of carbon dioxide (PaCO2) and pH] were measured at baseline; 30, 60, 90, and 120 min after CO2 insufflation; and 30 min after desufflation. Pain parameters [numeric rating scale (NRS) score, number of analgesics (NA), and bottom hit count (BHC)] were measured at 2, 24, 48, and 72 h after surgery. RESULTS: We found no statistically significant differences between the two groups in terms of any demographic or baseline characteristic. The clinicopathological and oncological outcomes did not differ significantly between the two groups, but the operation time was longer for the gasless group (187.50 ± 42.64 vs. 212.50 ± 35.88 min; P = 0.028). In terms of the hemodynamic, metabolic, and pain parameters, the pH fell significantly less in the gasless group (P = 0.047), but there were no significant between-group differences in the HR, MAP, CO, CI, PaCO2, NRS, NA, or BHC. No safety concerns arose. CONCLUSION: The new, gasless BABA RoT technique employing the da Vinci robotic surgical system is safe. Although metabolic changes during operation are thereby minimized, gasless BABA RoT should be used carefully when engaging in thyroid surgery; more experience is required.
引用
- Shin IB, Koo DH, Ko MJ, et al. A prospective, randomized controlled study of the safety and efficacy of gasless bilateral axillo-breast approach (BABA) robotic thyroidectomy. Surg Endosc. 2019. PMID: 31848757. doi:10.1007/s00464-019-07262-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。