文献速递肝胆胰外科

术前三维规划与ICG荧光融合实时导航用于腹腔镜肝切除

Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging.
PubMed 文献 · Surg Endosc · 2019-11-08

LHNS组术中出血量、输血率和术后住院时间均显著低于非LHNS组,手术时间和总体并发症率无差异。

要点

  • LHNS融合术前3D规划与ICG荧光实现实时导航,可行且临床有用。
  • LHNS组出血量、输血率及术后住院时间均优于非导航组。
  • 手术时间与总体并发症率两组无统计学差异。

核心结论

  • LHNS可解决当前术中成像系统的局限,有望成为腹腔镜肝切除有前景的实时导航系统。

主要发现

  • LHNS组出血量285.0 ± 163.0 mL,非LHNS组391.1 ± 242.0 mL,P = 0.047。
  • LHNS组术中输血率13.3%,非LHNS组38.2%,P = 0.045。
  • LHNS组术后住院时间7.8 ± 2.1天,非LHNS组10.6 ± 3.8天,P < 0.001。
  • 两组手术时间和总体并发症率无统计学差异。
  • LHNS在27例中清晰勾勒肝离断线,2例边界投影不清,1例ICG荧光未清晰显示边界。

临床怎么用

  • 对于腹腔镜肝切除,可考虑采用LHNS融合术前3D规划与ICG荧光进行实时导航,以减少出血和输血、缩短住院时间。

局限性

  • 本研究为回顾性 review,样本量64例,非随机对照。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Understanding the internal anatomy of the liver remains a major challenge in anatomical liver resection. Although virtual hepatectomy and indocyanine green (ICG) fluorescence imaging techniques have been widely used in hepatobiliary surgery, limitations in their application for real-time navigation persist. OBJECTIVE: The aim of the present study was to evaluate the feasibility and clinical utility of the novel laparoscopic hepatectomy navigation system (LHNS), which fuses preoperative three-dimensional (3D) models with ICG fluorescence imaging to achieve real-time surgical navigation. METHODS: We conducted a retrospective review of clinical outcome for 64 patients who underwent laparoscopic hepatectomy from January 2018 to December 2018, including 30 patients who underwent the procedure using the LHNS (LHNS group) and 34 patients who underwent the procedure without LHNS guidance (Non-LHNS group). RESULTS: There was no significant difference in preoperative characteristics between the two groups. The LHNS group had a significantly less blood loss (285.0 ± 163.0 mL vs. 391.1 ± 242.0 mL; P = 0.047), less intraoperative blood transfusion rate (13.3% vs. 38.2%; P = 0.045), and shorter postoperative hospital stay (7.8 ± 2.1 days vs. 10.6 ± 3.8 days; P < 0.001) than the Non-LHNS group. There was no statistical difference in operative time and the overall complication rate between the two groups. The liver transection line was clearly delineated by the LHNS in 27 patients; however, the projection of boundary was unclear in 2 cases, and in 1 case, the boundary was not clearly displayed by ICG fluorescence imaging. CONCLUSIONS: We developed the LHNS to address limitations of current intraoperative imaging systems. The LHNS is hopefully to become a promising real-time navigation system for laparoscopic hepatectomy.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Zhang P, Luo H, Zhu W, et al. Real-time navigation for laparoscopic hepatectomy using image fusion of preoperative 3D surgical plan and intraoperative indocyanine green fluorescence imaging. Surg Endosc. 2019. PMID: 31705286. doi:10.1007/s00464-019-07121-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。