文献速递胃肠外科围术期管理与 ERAS急腹症与外科感染

加压腹腔内气溶胶化疗(PIPAC)可能较HIPEC增加吻合口漏风险:一项实验研究

Pressurized intraperitoneal aerosol chemotherapy (PIPAC) might increase the risk of anastomotic leakage compared to HIPEC: an experimental study.
PubMed 文献 · Surg Endosc · 2019-08-27

本研究在16头健康猪中比较PIPAC与HIPEC联合结肠切除吻合术后的吻合口漏(AL)发生率及循环参数。PIPAC组采用7.5 mg/m2顺铂,HIPEC组采用70 mg/m2顺铂、目标腹腔温度42°C。PIPAC组8头中3头(37.5%)发生AL,HIPEC组无AL(p=0.20);微循环参数无显著差异。

要点

  • 健康猪模型中PIPAC组吻合口漏发生率为37.5%(3/8),HIPEC组为0,差异未达统计学显著。
  • PIPAC组吻合口漏风险未显示与微循环参数改变相关。
  • 建议PIPAC避免与消化道切除同时进行,围术期浆膜损伤时应避免使用。

核心结论

  • 在健康猪模型中,PIPAC相比HIPEC可能增加吻合口漏发生率,但差异无统计学意义。
  • 该潜在过风险似乎与微循环变化无关。
  • PIPAC可能不应与消化道切除联合使用,围术期浆膜损伤时应避免。

研究设计与样本

  • 实验研究,使用16头健康猪行节段性结肠切除及手工吻合。
  • 8头接受PIPAC(顺铂7.5 mg/m2),8头接受闭合式HIPEC(顺铂70 mg/m2,目标腹腔温度42°C)。
  • 术后观察8天,处死后尸检评估吻合口漏,定义为局部脓肿或加压时消化液漏。

主要发现

  • HIPEC组无吻合口漏,PIPAC组8头中3头(37.5%)发生吻合口漏(p=0.20)。
  • HIPEC组围术期心率和核心体温升高。
  • 术中第3和第4时间点HIPEC组心率较高(分别为123 vs. 93 bpm,p=0.031;110 vs. 85 bpm,p=0.010)。
  • 其他宏循环和微循环参数无显著差异。

关键数值与推荐

  • PIPAC方案:顺铂7.5 mg/m2。
  • HIPEC方案:顺铂70 mg/m2,目标腹腔温度42°C。
  • 吻合口漏定义:尸检时局部脓肿或加压吻合口时消化液漏。

临床怎么用

  • 临床考虑PIPAC时应避免同时行消化道切除吻合。
  • 围术期存在浆膜损伤时宜避免使用PIPAC。
  • 需进一步临床研究验证PIPAC对吻合口愈合的影响。

局限性

  • 样本量小(16头猪),统计效能有限。
  • 动物模型为健康猪,未必完全反映人类腹膜癌病生理状态。
  • 吻合口漏发生率差异未达统计学显著(p=0.20)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Pressurized intraperitoneal aerosol chemotherapy (PIPAC) and hyperthermic intraperitoneal chemotherapy (HIPEC) are technics proposed to treat patients with peritoneal carcinomatosis, in different settings. There is some concern about an over-risk of anastomotic leakage (AL) with PIPAC jeopardizing a combination with cytoreductive surgery. This study used a healthy swine model to compare the postoperative AL rate between PIPAC and HIPEC with digestive resection and to analyze macrocirculation and microcirculation parameters. METHODS: Segmental colonic resection with a handsewn anastomosis was performed on 16 healthy pigs; 8 pigs had a PIPAC procedure with 7.5 mg/m2 cisplatin (PIPAC group), and 8 pigs had a closed HIPEC procedure with 70 mg/m2 cisplatin and 42 °C as the target intraperitoneal temperature (HIPEC group). Pigs were kept alive for 8 days, then sacrificed and autopsied to look for AL, which was defined as local abscess or digestive fluid leakage when pressure was applied to the anastomosis. Food intake, weight, and core temperature were monitored postoperatively. Macrocirculation (heart rate, systolic blood pressure) and microcirculation parameters (percentage of perfused vessels, perfused vessels density, DeBacker score) were evaluated intraoperatively at five timepoints. Results were compared between pigs with AL and those without. RESULTS: The HIPEC group had no AL, but 3 of 8 pigs (37.5%) had AL in the PIPAC group (p = 0.20). Heart rate and core temperature showed perioperative increases in the HIPEC group. Intraoperatively, heart rate was higher in the HIPEC group at the two last timepoints (123 vs. 93 bpm, p = 0.031, and 110 vs. 85 bpm, p = 0.010, at timepoints 3 and 4, respectively). Other macrocirculatory and microcirculatory parameters showed no significant differences. CONCLUSION: In this healthy swine model, PIPAC might have increased AL incidence compared to HIPEC. This potential over-risk did not seem to be related to changes in the microcirculation. PIPAC should probably not be used with digestive resection and should be avoided in cases of perioperative serosal injury.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Tavernier C, Passot G, Vassal O, et al. Pressurized intraperitoneal aerosol chemotherapy (PIPAC) might increase the risk of anastomotic leakage compared to HIPEC: an experimental study. Surg Endosc. 2019. PMID: 31456025. doi:10.1007/s00464-019-07076-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。