文献速递胃肠外科

术中阻抗平面测量评估胃食管交界可扩张性并预测胃底折叠术后结局

Using impedance planimetry (EndoFLIP™) in the operating room to assess gastroesophageal junction distensibility and predict patient outcomes following fundoplication.
PubMed 文献 · Surg Endosc · 2019-06-19

本研究基于2013至2018年175例接受腹腔镜胃底折叠术(多数合并食管裂孔疝修补)患者的前瞻性数据库,术中采用EndoFLIP测量最小直径、球囊压力及扩张指数。结果显示最终扩张指数<2.0 mm2/mmHg与术后1年及2年更多气胀和吞咽困难相关,最终扩张指数2.0–3.5 mm2/mmHg者1年反流症状指数更低。

要点

  • 脚关闭和胃底折叠后球囊压力显著升高、扩张指数显著降低。
  • 最终扩张指数<2.0 mm2/mmHg与术后1年及2年更多气胀和吞咽困难相关。
  • 最终扩张指数2.0–3.5 mm2/mmHg者1年反流症状指数显著更低。

核心结论

  • EndoFLIP测量与患者结局良好相关,最终扩张指数在2至3.5 mm2/mmHg之间可能为理想范围。

研究设计与样本

  • 前瞻性维护的质量数据库查询,2013至2018年175例接受腹腔镜胃底折叠术(多数合并食管裂孔疝修补)患者,术中多个时间点行EndoFLIP测量,结局随访至术后2年。

主要发现

  • 与初始测量及疝复位后测量相比,脚关闭和胃底折叠导致球囊压力显著升高、扩张指数显著降低。
  • 术后1年,最终扩张指数<2.0 mm2/mmHg者气胀和吞咽困难显著多于最终扩张指数≥2.0 mm2/mmHg者(p=0.040和p=0.025)。
  • 术后2年差异更明显(p=0.006和p=0.004),最终扩张指数<2.0 mm2/mmHg与每日气胀患病率更高显著相关(43.8% vs. 12.0%;p=0.03)。
  • 最终扩张指数在2.0至3.5 mm2/mmHg之间的患者1年反流症状指数显著低于最终扩张指数<2.0或>3.5 mm2/mmHg者(p=0.042)。

临床怎么用

  • 术中可用EndoFLIP在脚关闭和胃底折叠后提供食管可扩张性的客观测量,辅助评估手术效果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The purpose of this study is to evaluate the utility of using a functional lumen imaging probe (EndoFLIP™) intra-operatively during hiatal hernia repair and fundoplication. Additionally, we hypothesize that these measurements correlate with long-term outcomes. METHODS: A prospectively maintained quality database was queried. Between 2013 and 2018, 175 patients underwent laparoscopic fundoplication, the majority of which also had a hiatal hernia repair. The EndoFLIP™ was used to measure minimum diameter (Dmin), balloon pressure, and distensibility index (DI) at different timepoints throughout the operation. Clinical outcomes were measured up to 2 years after treatment. RESULTS: Crural closure and fundoplication resulted in a significant increase in balloon pressure and decrease in DI when compared to initial measurements as well as measurements taken after hernia reduction. After 1 year, patients with a final DI < 2.0 mm2/mmHg reported significantly more gas bloat and dysphagia than those with a final DI ≥ 2.0 mm2/mmHg (p = 0.040 and p = 0.025, respectively). This disparity became even more dramatic at 2 years (p = 0.006 and p = 0.004, respectively), with a final DI < 2.0 mm2/mmHg being significantly associated with higher prevalence of daily gas bloat (43.8% vs. 12.0%; p = 0.03). Additionally, patients with a final DI between 2.0 and 3.5 mm2/mmHg reported significantly lower Reflux Symptom Index scores at one year compared to those with a final DI < 2.0 or > 3.5 mm2/mmHg (p = 0.042). CONCLUSION: EndoFLIP™ measurements correlate well with patient outcomes, with a final DI between 2 and 3.5 mm2/mmHg potentially being ideal. The EndoFLIP™ can be a useful adjunct in the operating room by providing objective measurements of esophageal distensibility after crural closure and fundoplication.

来源:Surg Endosc,查看原文。版权归原作者所有。

引用

  1. Su B, Novak S, Callahan ZM, et al. Using impedance planimetry (EndoFLIP™) in the operating room to assess gastroesophageal junction distensibility and predict patient outcomes following fundoplication. Surg Endosc. 2019. PMID: 31218421. doi:10.1007/s00464-019-06925-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。