新型锚定式套管针穿刺点闭合系统与标准缝线闭合的前瞻性随机对照试验
本研究在35例BMI≥35 kg/m²的腹腔镜减重手术患者中,随机比较neoClose®装置与标准缝线穿引器闭合≥10 mm穿刺点筋膜的效果。结果显示neoClose®组闭合时间更短(20.2 vs 30.0秒,p=0.0002)、术后疼痛更轻(0.3 vs 0.9,p=0.002)、进针深度更浅(3.3 vs 5.2 cm,p<0.0001),两组一年随访均无套管针穿刺点疝发生。
要点
- 肥胖患者腹腔镜减重术中,neoClose®装置闭合筋膜比标准缝线穿引器更快且疼痛更轻。
- neoClose®装置可减少腹腔内进针深度,可能降低脏器损伤风险。
- 两组一年随访均无套管针穿刺点疝,但样本量小需更大队列验证。
核心结论
- 在肥胖腹腔镜减重手术患者中,neoClose®装置较标准缝线穿引器缩短筋膜闭合时间、减少术后疼痛并降低进针深度。
研究设计与样本
- 前瞻性随机对照试验,两组平行设计,共35例BMI≥35 kg/m²行腹腔镜袖状胃切除术或Roux-en-Y胃旁路术的患者随机分组。
主要发现
- neoClose®组闭合时间为20.2秒,标准缝线穿引器组为30.0秒(p=0.0002)。
- neoClose®组穿刺点闭合处术后疼痛评分为0.3,标准组为0.9(p=0.002)。
- neoClose®组腹腔内进针深度为3.3 cm,标准组为5.2 cm(p<0.0001)。
- 两组一年随访均无套管针穿刺点疝发生。
关键数值与推荐
- 对≥10 mm的穿刺套管针穿刺点行筋膜闭合,研究组使用neoClose®装置,对照组使用标准缝线穿引器。
临床怎么用
- 肥胖患者腹腔镜减重手术中,可考虑使用neoClose®装置闭合≥10 mm穿刺点筋膜以缩短操作时间并减轻术后疼痛。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Patients with obesity have a higher risk of trocar site hernia. The objective of the present study was to compare a standard suture passer versus the neoClose® device for port site fascial closure in patients with obesity undergoing laparoscopic bariatric surgery. METHODS: This is a randomized, controlled trial with two parallel arms. Thirty five patients with BMI ≥ 35 kg/m2 and undergoing laparoscopic sleeve gastrectomy or Roux-en-Y gastric bypass were randomized to each group. Port site fascial closure for trocars ≥ 10 mm was performed with the neoClose® device in the study group and the standard suture passer in the control group. Primary outcomes were time required to complete closure and intensity of postoperative pain at the fascial closure sites. Secondary outcomes were intraabdominal needle depth and incidence of trocar site hernia. RESULTS: The use of the neoClose® device resulted in shorter closure times (20.2 vs 30.0 s, p = 0.0002), less pain (0.3 vs 0.9, p = 0.002) at port closure sites, and decreased needle depth (3.3 cm vs 5.2 cm, p < 0.0001) compared to the standard suture passer. There was no trocar site hernia at the one-year follow-up in either group. CONCLUSIONS: Use of the neoClose® device resulted in faster fascial closure times, decreased intraoperative needle depth, and decreased postoperative abdominal pain at 1 week as compared to the standard suture passer. These data need to be confirmed on larger cohorts of patients with longer follow-up.
引用
- Iranmanesh P, Rivera AR, Bajwa KS, et al. Trocar site closure with a novel anchor-based (neoClose®) system versus standard suture closure: a prospective randomized controlled trial. Surg Endosc. 2019. PMID: 31183797. doi:10.1007/s00464-019-06891-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。